Goodman GM9S96 Скачать руководство пользователя страница 6

6

www. goodmanmfg

.com

SS-GM9S96-U

SS-GM9S96-U

www.goodmanmfg

.com

7

Wiring Diagram

Wiring 

is 

su

bject 

to 

cha

ng

e. 

Alw

ay

re

fer 

to 

the 

wiring 

diagr

am 

on 

the 

unit 

for 

the 

mos

t up-t

o-da

te 

wiring.

    

W

arning

High 

Volt

age:

 Disc

onnect 

all 

po

w

er 

be

for

ser

vicing 

or 

ins

talling 

this 

unit. 

Multiple 

po

w

er 

 

sour

ces 

ma

be 

pr

esen

t. 

Failur

to 

do 

so 

ma

cause 

pr

operty 

damag

e, 

per

sonal 

injur

y, 

or 

dea

th.

GND

IDB(2)

HSI(1)

AUTO RESET BURNER

BOX LIMIT

LINE

 NE
UT

R

AL

S

Ø /60 HZ POWER SUPPLY WITH

TO 120VAC/ 1

C GAS

VALVE

M

WARNING:

Y

G

C

TO

MICRO

TR (2)

GND

MVC (5)

BLI (11)

GN

FLAME SENSOR

ID

BLOWER

HOT SURFACE

IGNITER

FS

SWITCH

DOOR

OVERCURRENT PROTECTION DEVICE

N

L

DISCONNECT

GND

INT

EG

RA

TE

D CO

NT

RO
L M

O

DU

LE

XFMR-H

LINE-H

JUNCTION BOX

INTEGRATED CONTROL MODULE

TH (6)

BEFORE SERVICING.

DISCONNECT POWER

MUST BE

WIRING TO UNIT
PROPERLY
AND GROUNDED.

POLARIZED

PRESSURE

TRANSDUCER

PSO (12)

HLO (4)

W

BLOWER

CIRCULATOR

GND

GND

MVC (8)

BLWR

AIR

INDOOR

CIRCULATOR

TO R

TO MICRO

GN

GND

JU

NC

TIO

N

 B

O

X

BURNER COMPARTMENT

PRESSURE TRANSDUCER

BLOWER

COMPARTMENT

DOOR-SWITCH

(OPEN WHEN

DOOR OPEN)

RD

ECM MTR

HARNESS

RD

BK

RD

GN

BK

BK

BLOWER

CIRCULATOR

BK

GN

RD

3

1

WH

2

4

BL

5

4

3

2

1

WH

40 VA

TRANSFORMER

115

VAC

24

VAC

BK

BR

BR GR

BL

BL

PK BR

PU

SEN

SO
R

YL

FL

AM
E

BL

1

2

M

C

BLOWER COMPARTMENT

AUTO RESET AUXILIARY

LIMIT CONTROL

PU

BL

AUTO RESET PRIMARY

LIMIT CONTROL

BK

GND

BLOWER

DRAFT (ID)

INDUCED

1
2
3

RD

WH

BK

RD

WH

BR

OR

2 CIRCUIT

CONNECTOR

HOT

SURFACE

IGNITER

WARNING:DISCONNECT

N

TO UNIT MUST BE
AND GROUNDED.

L

SERVICING. WIRING

DISCONNECT

GND

W

H

BK

POWER BEFORE

PROPERLY POLARIZED

WH

NO

C

ID BLOWER

PRESSURE

SWITCH

OR

PK

BK

RD

W

H

2

1

WH

WH

BL

RD

OR

BK

YL

YL

BK

OR

RD

BL

W

H

BK

BK

Status & Fault

(see installation manual for complete list of faults)

Seven Segment Display

Seg. 1

Seg. 2

Seg. 3

Idle

1

d

L

Continuous fan

F

A

n

Low Stage Cooling

1

A

C

High Stage Cooling

2

A

C

Gas Heat

g

H

HP Heat, Low Stage

1

H

P

HP Heat, High Stage

2

H

P

Defrost

d

F

t

Lockout Due to Excessive Retries Recycle

E

E

0

Pressure Switch Closed When Expected To Be Open

E

E

1

Pressure Switch Open When Expected To Be Closed

E

E

2

Open High Limit Switch

E

E

3

Flame Detected When No Flame Should Be Present

E

E

4

Open Fuse

E

E

5

Low Flame Signal

E

E

6

Ignitor Fault Or Ignitor Relay Fault

E

E

7

Reversed Line Polarity

E

E

A

Grounding Error

E

1

0

Inernal Gas Valve Error

E

E

b

External Gas Valve Error

E

E

C

Aux Limit Switch Open

E

E

d

Burner Limit Switch Open

E

1

I

ALI (1)

HLI (7)

NO
TE

 5

NO
TE

 6

0140F02647-A

CR48

SW1

SW2

E28

E5

E2

2

E4

7

W11

BLW

E32

YL

W

H

Ø /60 HZ

OVERCURRENT

115 VAC/ 1

TO

POWER SUPPLY WITH
PROTECTION DEVICE

E4

PK

PU

AUTO RESET

BAFFLE LIMIT

GAS VALVE

BR

NO

C

GY

BR

BL

AUTO RESET

BURNER BOX LIMIT

AUTO RESET

AUXILIARY

LIMIT CONTROL

PU

YL

PU

PK

OUTPUT

NOTES:

1. MANUFACTUR'S SPECIFIED REPLACEMENT

 PARTS MUST BE USED WHEN SERVICING.

2. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED

 WITH THE FURNACE MUST BE REPLACED, IT

 MUST BE REPLACED WITH WIRING MATERIAL

 HAVING A TEMPERATURE RATING OF AT LEAST

105°C. USE COPPER CONDUCTORS ONLY.

3. BLOWER SPEEDS SHOULD BE ADJUSTED BY

 INSTALLER TO  MATCH THE INSTALLATION

 REQUIREMENTS SO AS TO PROVIDE

 THE CORRECT HEATING TEMPRATURE

 RISE AND THE CORRECT COOLING CFM.

4. UNIT MUST BE PERMANENTLY GROUNDED

 AND CONFORM TO N.E.C. AND LOCAL CODES.

5. EAC. NORMALLY OPEN CONTACTS FOR OPTIONAL

 ELECTRONIC AIR CLEANER USE. CONTACTS

 CLOSE

 WHEN INDOOR BLOWER IS RUNNING. TERMINALS

 ARE NOT INTERNALLY POWERED

6. HUM. NORMALLY OPEN CONTACTS FOR OPTIONAL

 HUMIDIFIER USE. CONTACTS CLOSE WHEN DRAFT

 INDUCER IS RUNNING. TERMINALS ARE NOT

 INTERNALLY POWERED

SWITCH (PRESS.)

FIELD SPLICE

FIELD GND

EQUIPMENT GND

INTERNAL TO

PROT. DEVICE

INTEGRATED CONTROL

PLUG CONNECTION

SWITCH (TEMP.)

JUNCTION

OVERCURRENT

TERMINAL

IGNITER

LOW VOLTAGE (24V)

LOW VOLTAGE FIELD

HI VOLTAGE (120V)

HI VOLTAGE FIELD

PK PINK

COLOR CODES:

RD RED

GY GRAY

WH WHITE

PU PURPLE

OR ORANGE

YL YELLOW

BL BLUE
BR BROWN

BK BLACK

GR GREEN

TAP1

E35

E44

E43

E42

EA

C

HUM

E23

NE

UT

RA

L

E46

E25

E26

E1

9

W12

MVL(9)

ID BLOWER

PRESSURE SWITCH

AU

TO

 RESET
 PR

IMAR

Y

LIM

IT C

ON

TR

OL

AUTO RESET

BAFFLE LIMIT

WH

NO

C

NO

C

GND

AUTO RESET AUXILIARY

LIMIT CONTROLS

O W1

B\C

R G

Y1

TWIN

PSO

BLI

MVH

MVL

GND

HLI

TH

MVC

HLO

PS1

TR

ALI

TAP2

TAP3

TAP4

TAP5

GND

Y2

FP

E39

E41

U

V

W

LINE

N

H

FU

SE

24 VAC

40 VA

TRANSFORMER

120 VAC

GND

PI

5V

BK

RD

GN

2

1

3

4

UNUSED

5V

GND

PI

 (1)

(4)

(3)

E

1

8

PS1 (3)

E18

Downloaded from 

ManualsNet.com

 search engine

Содержание GM9S96

Страница 1: ...a LED Eligible for installation in California s South Coast Air Quality Management District SCAQMD and San Joaquin Valley Air Pollution Control District SJVUAPCD This furnace complies with the 14 ng J...

Страница 2: ...Horizontal N 40 NG J NOx C Downflow Horizontal X 40 NG J NOx U 14NG J NOx Motor Cabinet Width 9 Nine Speed ECM A 14 C 21 B 17 D 24 Gas Valve Maximum CFM C Two Stage 3 1200 CFM 4 1600 CFM S Single Stag...

Страница 3: ...is dependent on installation code requirements and must be 2 or 3 diameter PVC Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire size should be determined in accordance with...

Страница 4: ...cal Outlet Alternate Gas Supply Low Voltage Electrical Outlet Standard Gas Supply Location Center Dimple For Alternate Air Intake Pipe 3 OD Hole Air Intake 2 Pipe Left Side Drain Trap Exterior Holes H...

Страница 5: ...F01 999 934 877 814 740 681 615 554 F02 1297 1245 1194 1143 1096 1044 991 933 F03 1407 1354 1307 1257 1210 1164 1118 1067 F04 1532 1488 1440 1396 1352 1304 1259 1210 F05 1641 1594 1552 1509 1477 1425...

Страница 6: ...Switch E E 3 Flame Detected When No Flame Should Be Present E E 4 Open Fuse E E 5 Low Flame Signal E E 6 Ignitor Fault Or Ignitor Relay Fault E E 7 Reversed Line Polarity E E A Grounding Error E 1 0...

Страница 7: ...UT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Temperature Rise Outpu...

Страница 8: ...de or bottom 1 20 x 25 bottom or 2 16 x 25 side Note Other size filters of equal or greater dimensions may be used Filters may also be centrally located Model Description GM9S96 0403BU GM9S96 0603BU G...

Отзывы: