Goodman GM9S96 Скачать руководство пользователя страница 3

2

www. goodmanmfg

.com

SS-GM9S96-U

SS-GM9S96-U

www.goodmanmfg

.com

3

GM9S96-U Product Specifications

GM9S96

0403BU

GM9S96

0603BU

GM9S96

0805CU

Heating Data

High Fire Input¹

40,000

60,000

80,000

High Fire Output¹

38,400

57,600

76,800

AFUE²

96

96

96

Temperature Rise Range (°F)

15 - 45

30 - 60

30 - 60

Vent Diameter³

2" - 3"

2" - 3"

2" - 3"

No. of Burners Ports

2

3

4

Circulator Blower

Available AC @ 0.5" ESP

1.5 - 3

1.5 - 3

2.5 - 5

Size  (D x W)

10" x 8"

11" x 8"

11" x 10"

Horsepower @ 1075 RPM

½

½

1

Speed

9

9

9

Filter Size (in²) (Qty)

(1) 16 x 25

(side or 

 

 bottom)

(1) 16 x 25

(side or 

 

 bottom)

(1) 20 x 25 

 

(bottom) 

or (2) 16 x 25 

(side)

Electrical Data

Min. Circuit Ampacity⁴

10.8

10.8

16.1

Max. Overcurrent Device (amps)⁵

15

15

20

Shipping Weight (lbs)

115

120

145

¹ 

Natural Gas BTU/h

²  DOE AFUE based upon Isolated Combustion System (ICS)
³  Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). 

 

Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run 

 

and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements 

 

and must be 2" or 3" diameter PVC.

⁴ 

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined 

 

in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

⁵  Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. 

 

May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

• 

All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.

• 

Gas Service Connection ½" FNPT

• 

Important: Size fuses and wires properly and make electrical connections in accordance with the 

 

National Electrical Code and/or all existing local codes.

• 

For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance 

 

and noise issues.

• 

For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) 

 

may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility 

 

clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

Downloaded from 

ManualsNet.com

 search engine

Содержание GM9S96

Страница 1: ...a LED Eligible for installation in California s South Coast Air Quality Management District SCAQMD and San Joaquin Valley Air Pollution Control District SJVUAPCD This furnace complies with the 14 ng J...

Страница 2: ...Horizontal N 40 NG J NOx C Downflow Horizontal X 40 NG J NOx U 14NG J NOx Motor Cabinet Width 9 Nine Speed ECM A 14 C 21 B 17 D 24 Gas Valve Maximum CFM C Two Stage 3 1200 CFM 4 1600 CFM S Single Stag...

Страница 3: ...is dependent on installation code requirements and must be 2 or 3 diameter PVC Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire size should be determined in accordance with...

Страница 4: ...cal Outlet Alternate Gas Supply Low Voltage Electrical Outlet Standard Gas Supply Location Center Dimple For Alternate Air Intake Pipe 3 OD Hole Air Intake 2 Pipe Left Side Drain Trap Exterior Holes H...

Страница 5: ...F01 999 934 877 814 740 681 615 554 F02 1297 1245 1194 1143 1096 1044 991 933 F03 1407 1354 1307 1257 1210 1164 1118 1067 F04 1532 1488 1440 1396 1352 1304 1259 1210 F05 1641 1594 1552 1509 1477 1425...

Страница 6: ...Switch E E 3 Flame Detected When No Flame Should Be Present E E 4 Open Fuse E E 5 Low Flame Signal E E 6 Ignitor Fault Or Ignitor Relay Fault E E 7 Reversed Line Polarity E E A Grounding Error E 1 0...

Страница 7: ...UT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Temperature Rise Outpu...

Страница 8: ...de or bottom 1 20 x 25 bottom or 2 16 x 25 side Note Other size filters of equal or greater dimensions may be used Filters may also be centrally located Model Description GM9S96 0403BU GM9S96 0603BU G...

Отзывы: