background image

10

www.goodmanmfg.com

SS-GMVM96

SS-GMVM96

www.goodmanmfg.com

11

P

roduct

 S

PecificationS

P

roduct

 S

PecificationS

w

iriNG

 d

iaGraM

Wiring is subject t

o chang

e. Alw

ay

re

fer 

to the wiring diagr

am or the 

unit 

for the mos

t up-t

o-da

te 

wiring.

    

W

arning

High 

Volt

ag

e:

 Disc

onn

ect 

all 

po

w

er

 be

for

ser

vicing 

or 

in

st

alling 

this 

unit. 

Multiple 

po

w

er 

 

sour

ces 

ma

be pr

esen

t. F

ailur

to do 

so ma

cause pr

operty 

damag

e, 

per

sonal 

injur

y, 

or dea

th.

OPTIONAL

OPTIONAL

OPTIONAL

TR (9)

PRESS. SWITCH

FRONT COVER

LIMIT CONTROLS

MANUAL RESET ROLLOUT

PRESS. SWITCH

LOW FIRE PRESS.

LIMIT CONTROL

AUTO RESET PRIMARY

AUTO RESET AUXILIARY LIMIT

24 VAC

TO +VDC

TR (5)

FUSE 3A

40 VA

HOT SURFACE

3Ø ID

INTEGR

ATED 

C

O

NTR

OL M

O

D

U

LE

AIR CLEANER

115kBTU MODELS

POLARIZED AND

MUST BE PROPERLY

WIRING TO UNIT

BEFORE SERVICING

DISCONNECT POWER

OVERCURRENT PROTECTION DEVICE

Ø /60 HZ POWER SUPPLY WITH

TO 115VAC/1

SWITCH ASSEMBLY

ID BLOWER TWO-STAGE PRESSURE

SWITCH

LOW FIRE

(HONEY WELL)

GAS VALVE

2 CIRCUIT

PRESSURE SWITCH

FRONT COVER

(SINGLE CONTROL ON 45 kBTU)

MANUAL RESET ROLLOUT LIMIT CONTROLS

LIMIT CONTROL

AUTO RESET PRIMARY

BURNER COMPARTMENT

BLOWER COMPARTMENT

AUTO RESET

LIMIT CONTROL

FU

R

NACE CONTROL 

M

OD
ULE

M

O

D

UL

ATI
NG I

N

TERGRA

TED

CO
OL TAP

S

HE
AT TAPS

FA

N TAPS

DIP SWITCH

ES

HE
AT O

FF

HE
AT SET

UP

CO
OL S

ETUP

PUL
L UP

PUL
L D
OWN

24 V THERMOSTAT CONNECTIONS

24V HU

M.

INTEGR

ATED 

C

O

NTR

OL M

O

D

U

LE

24V TH

ER
M

OSTAT 

CO
N

NE
CTIO

NS

115kBTU MODELS

(OPEN WHEN

DOOR SWITCH

24 V 3A

ECM MTR

IN STANDBY (NO THERMOSTAT INPUTS)

RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE

5. TO RECALL THE LAST 10 FAULTS, MOST RECENT TO LEAST

N.E.C. AND LOCAL CODES.

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO

LEAST 105°C. USE COPPER CONDUCTORS ONLY.

WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT

FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE

USED WHEN SERVICING.

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

BK BLACK

PU PURPLE

YL YELLOW

BL BLUE

WH WHITE

BR BROWN

PK PINK

COLOR CODES:

PLUG CONNECTION

INTEGRATED CONTROL

INTERNAL TO

HI VOLTAGE FIELD

HI VOLTAGE (115V)

LOW VOLTAGE (24V)

LOW VOLTAGE FIELD

PROT. DEVICE

SWITCH PRESSURE

SWITCH (TEMP)

FIELD SPLICE

EQUIPMENT GND

PROPERLY POLARIZED

TO UNIT MUST BE

SERVICING WIRING.

POWER BEFORE

POWER SUPPLY WITH

115 VAC/1

HZ

Ø /60

TO

MICRO

TO

R

GND (4)

+ VDC (1)

RX (2)

TX (3)

CIRCULATOR

INDOOR

AIR

BLWR

RD GY

BL

BK

HUMIDIFIER

GND

PROTECTION

DEVICE

LINE

RD

TO

C

BK

RD

IGNITER

FLAME

SENSOR

INTEGRATED CONTROL

MODULE

OR

TERMINAL

OR ORANGE

PM

HARNESS

NO

(12)

3

C

CIRCULATOR

BK

BK

OVERCURRENT

24V

HUM.

0140F00863-B

IGNITER

24

PM

INDUCED

DRAFT

BLOWER

EAC

C

115

VAC

INDUCTOR COIL

C

PU

YL

DEHUM

GND

2

HOT

SURFACE

IGNITER

(7)

NEUTRAL

DOOR

SWITCH

4

3
2

C

HASSIS

GRO

UN
D

WH

VAC

GND

YL

CONNECTOR

HUM

OVERCURRENT

(6)

ONLY

C

MODULATING

DISCONNECT

HIGH FIRE

INDOOR

HUMIDIFIER

N

1

CONTROLS

OR

JUNCTION

BLWR

CIRCULATOR BLOWER

R

1

GND

JUNCTION BOX

NEUTRAL

BLOWER

COMPARTMENT

DOOR OPEN)

C

LINE

BK

4

NEUTRAL

C

FS

2

DISCONNECT

PU

HIGH FIRE

PRESSURE

SWITCH

ONLY

W1

70kBTU,90kBTU,

NO

(8)

O

WH

5

GND (4)

BK

3

IGN

PK

GY

(3)

70kBTU,90kBTU,

NOTES:

PU

L

AIR

WH

Y1

GY GRAY

ELECTRONIC

RD RED

Y2

OR

NEUTRAL

1

(11)

WH

SWITCH

NO

WH

TRANSFORMER

BR

BL

GR

2

GROUNDED.

W2

WARNING:

FIELD GND

WH

115

NEUTRAL

BLWR

JU

N

CTION BOX

GND

1

AND GROUNDED.

RD

GAS

VALVE

PU

INDUCTOR COIL

C

1

VAC

G

C

GR

GR GREEN

FLAME

SENSOR

(2)

PRESSURE

1

L

BR

NO

3

NO

N

GY

OR

TO

MICRO

WARNING:DISCONNECT

PK

AUXILIARY

2

NO

BL

GY

BK

RD

OR

BR

BK

WH

RD

OR

WH

WH

WH

WH

BK

YL

OR

BIAS

2

FUSE

AD
JU

ST

LINE

D

EHU
M

2

3

1

NE
UT
RAL

3

D

E

LAY

1

FLA
ME

SE
NS
OR

4

DIAGNOSTIC

LED'S

O

G

ID B
LOWER

CO
NNE

CTOR

Y2

H

UM

EAC

W1

R

2

Y1

1

C

W2

DEHUM

10

6

3

4

5

2

7

11

1

12

8

9

HSI

AUX

OR

2

GND

(10)

BR

OR

BK

BR

40 VA

TR

ANSFOR

ME
R

GY

RA
MP
ING

BL

GY

Содержание GCVM96

Страница 1: ...All models comply with California NOx emissions standards Complete warranty details available from your local dealer or at www goodmanmfg com To receive the Lifetime Heat Exchanger Limited Warranty g...

Страница 2: ...Natural Gas H High Air ow X Low NOx K Dedicated Up ow M Up ow Horizontal Cabinet Width A 14 Descrip6on Motor B 17 V Two Stage Variable speed C 21 H Two Stage Mul speed D 24 S Single Stage Mul speed E...

Страница 3: ...2 14 2 6 0 14 2 14 2 Max Overcurrent Protection 15 0 15 0 15 0 15 0 15 0 15 0 15 0 Ship Weight lbs 135 145 170 170 139 165 170 Natural Gas BTU h DOE AFUE based upon Isolated Combustion System ICS Ins...

Страница 4: ...d one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input number of elbows length of run and installation 1 or 2 pipes The optional Combustion Air Pip...

Страница 5: ...21 19 16 18 19 GCVM960805DX 24 28 40 24 23 20 21 23 GCVM961005DX 24 28 40 24 23 20 21 23 Notes Installer must supply one or two PVC pipes one for combustion air optional and one for the flue outlet r...

Страница 6: ...ESP GMVM961005DX GMVM961155DX High Stage Low Stage High Stage Low Stage Tap Adjust CFM Tap Adjust CFM Tap Adjust CFM Tap Adjust CFM A Minus 711 A Minus 459 A Minus 711 A Minus 459 Normal 790 Normal 51...

Страница 7: ...DX Rise Range 35 65 F Adjust Tap CFM Rise F Adjust Tap CFM Rise F Minus 1 629 54 Minus 1 629 62 Normal 1 810 49 Normal 1 810 56 Plus 1 991 44 Plus 1 991 51 Minus 1 665 53 Minus 1 665 60 Normal 1 850 4...

Страница 8: ...7 Plus 1078 Plus 2068 Plus 1342 1 8 w c ESP Notes All furnaces ship as high speed for cooling Installer must adjust blower speed as needed For most jobs about 400 CFM per ton when cooling is desirable...

Страница 9: ...nus 1 719 41 Normal 1 590 33 Normal 1 910 37 Plus 1 749 30 Plus 2 101 34 1 5 w c ESP 1 5 w c ESP GCVM961005DX Rise Range 25 55 F Adjust Tap CFM Rise F Minus 1 557 56 Normal 1 730 51 Plus 1 903 46 Minu...

Страница 10: ...0 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1...

Страница 11: ...NY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE USED WHEN SERVICING 2 MANUFACTURER S SPECIFIED REPLACEMENT PARTS MUST BE 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS BK BLACK PU PURPLE YL YELLOW...

Страница 12: ...KM0D100UF LPKM0D115UF LPKM0D060CF LPKM0D080CF LPKM0D100CF EFR01 External Filter Rack DCVK 20 Horizontal Vertical Concentric Vent Kit 2 DCVK 30 Horizontal Vertical Concentric Vent Kit 3 CFB21 Downflow...

Отзывы: