GMVM96 a

irflow

 d

ata

 — C

ooliNG

 s

peeds

GMVM960603BX

GVMV960805CX

High Stage

Low Stage

High Stage

Low Stage

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Tap

Adjust

CFM*

A

Minus(-)

567

A

Minus(-)

351

A

Minus(-)

747

A

Minus(-)

486

Normal  

630

Normal  

390

Normal  

830

Normal  

540

Plus (+)

693

Plus (+)

429

Plus (+)

913

Plus (+)

594

B

Minus(-)

720

B

Minus(-)

495

B

Minus(-)

981

B

Minus(-)

675

Normal  

800

Normal  

550

Normal  

1090

Normal  

750

Plus (+)

880

Plus (+)

605

Plus (+)

1199

Plus (+)

825

C

Minus(-)

900

C

Minus(-)

612

C

Minus(-)

1314

C

Minus(-)

882

Normal  

1000

Normal  

680

Normal  

1460

Normal  

980

Plus (+)

1100

Plus (+)

748

Plus (+)

1606

Plus (+)

1078

D

Minus(-)

1089

D

Minus(-)

720

D

Minus(-)

1620

D

Minus(-)

1089

Normal  

1210

Normal  

800

Normal  

1800

Normal  

1210

Plus (+)

1331

Plus (+)

880

Plus (+)

1980

Plus (+)

1331

*   @ .1" - .8" w.c. ESP

*   @ .1" - .8" w.c. ESP

GMVM961005DX

GMVM961155DX

High Stage

Low Stage

High Stage

Low Stage

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Tap

Adjust

CFM*

A

Minus(-)

711

A

Minus(-)

459

A

Minus(-)

711

A

Minus(-)

459

Normal  

790

Normal  

510

Normal  

790

Normal  

510

Plus (+)

869

Plus (+)

561

Plus (+)

869

Plus (+)

561

B

Minus(-)

990

B

Minus(-)

639

B

Minus(-)

990

B

Minus(-)

639

Normal  

1100

Normal  

710

Normal  

1100

Normal  

710

Plus (+)

1210

Plus (+)

781

Plus (+)

1210

Plus (+)

781

C

Minus(-)

1269

C

Minus(-)

819

C

Minus(-)

1269

C

Minus(-)

819

Normal  

1410

Normal  

910

Normal  

1410

Normal  

910

Plus (+)

1551

Plus (+)

1001

Plus (+)

1551

Plus (+)

1001

D

Minus(-)

1647

D

Minus(-)

1044

D

Minus(-)

1647

D

Minus(-)

1044

Normal  

1830

Normal  

1160

Normal  

1830

Normal  

1160

Plus (+)

2013

Plus (+)

1276

Plus (+)

2013

Plus (+)

1276

*   @ .1" - .8" w.c. ESP

Notes:

•  All furnaces ship as high speed for cooling.  Installer must adjust blower speed as needed.
•  For most jobs, about 400 CFM per ton when cooling is desirable.
•  Operation is recommended below .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.

Содержание GCVM96

Страница 1: ...All models comply with California NOx emissions standards Complete warranty details available from your local dealer or at www goodmanmfg com To receive the Lifetime Heat Exchanger Limited Warranty g...

Страница 2: ...Natural Gas H High Air ow X Low NOx K Dedicated Up ow M Up ow Horizontal Cabinet Width A 14 Descrip6on Motor B 17 V Two Stage Variable speed C 21 H Two Stage Mul speed D 24 S Single Stage Mul speed E...

Страница 3: ...2 14 2 6 0 14 2 14 2 Max Overcurrent Protection 15 0 15 0 15 0 15 0 15 0 15 0 15 0 Ship Weight lbs 135 145 170 170 139 165 170 Natural Gas BTU h DOE AFUE based upon Isolated Combustion System ICS Ins...

Страница 4: ...d one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input number of elbows length of run and installation 1 or 2 pipes The optional Combustion Air Pip...

Страница 5: ...21 19 16 18 19 GCVM960805DX 24 28 40 24 23 20 21 23 GCVM961005DX 24 28 40 24 23 20 21 23 Notes Installer must supply one or two PVC pipes one for combustion air optional and one for the flue outlet r...

Страница 6: ...ESP GMVM961005DX GMVM961155DX High Stage Low Stage High Stage Low Stage Tap Adjust CFM Tap Adjust CFM Tap Adjust CFM Tap Adjust CFM A Minus 711 A Minus 459 A Minus 711 A Minus 459 Normal 790 Normal 51...

Страница 7: ...DX Rise Range 35 65 F Adjust Tap CFM Rise F Adjust Tap CFM Rise F Minus 1 629 54 Minus 1 629 62 Normal 1 810 49 Normal 1 810 56 Plus 1 991 44 Plus 1 991 51 Minus 1 665 53 Minus 1 665 60 Normal 1 850 4...

Страница 8: ...7 Plus 1078 Plus 2068 Plus 1342 1 8 w c ESP Notes All furnaces ship as high speed for cooling Installer must adjust blower speed as needed For most jobs about 400 CFM per ton when cooling is desirable...

Страница 9: ...nus 1 719 41 Normal 1 590 33 Normal 1 910 37 Plus 1 749 30 Plus 2 101 34 1 5 w c ESP 1 5 w c ESP GCVM961005DX Rise Range 25 55 F Adjust Tap CFM Rise F Minus 1 557 56 Normal 1 730 51 Plus 1 903 46 Minu...

Страница 10: ...0 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1...

Страница 11: ...NY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE USED WHEN SERVICING 2 MANUFACTURER S SPECIFIED REPLACEMENT PARTS MUST BE 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS BK BLACK PU PURPLE YL YELLOW...

Страница 12: ...KM0D100UF LPKM0D115UF LPKM0D060CF LPKM0D080CF LPKM0D100CF EFR01 External Filter Rack DCVK 20 Horizontal Vertical Concentric Vent Kit 2 DCVK 30 Horizontal Vertical Concentric Vent Kit 3 CFB21 Downflow...

Отзывы: