p
roduCt
s
peCifiCatioNs
SS-GMVC95
www.goodmanmfg.com
9
gCVC9 a
irflow
d
ata
Continous Fan Speeds
Model
Maximum
CFM
Continuous
Fan Speed¹
GMVC950453BX
1400
420
GMVC950704CX
1760
530
GMVC950905CX
2200
660
GMVC950905DX
2200
660
GMVC951155DX
2200
660
GCVC950704CX
1760
530
GCVC950905DX
2200
660
GCVC91155DX
2200
660
¹ Continuous fan speed is 30% of furnace maximum CFM
GCVC91155DX
Cooling Speeds
GCVC91155DX
Heating Speeds (Rise Range: 40 - 70°F)
High Stage
Low Stage
High Stage
Low Stage
Tap
Adjust
CFM*
Tap
Adjust
CFM*
Tap
Adjust
CFM*
Rise
Tap
Adjust
CFM*
Rise
A
Minus(-)
705
A
Minus(-)
457
A
Minus(-)
1583
63
A
Minus(-)
1093
63
Normal
783
Normal
508
Normal 1759
56
Normal 1214
56
Plus (+)
861
Plus (+)
559
Plus (+)
1935
51
Plus (+)
1335
51
B
Minus(-)
982
B
Minus(-)
621
B
Minus(-)
1612
61
B
Minus(-)
1106
61
Normal 1091
Normal
690
Normal 1791
55
Normal 1229
55
Plus (+)
1200
Plus (+)
759
Plus (+)
1970
50
Plus (+)
1352
50
C
Minus(-)
1265
C
Minus(-)
815
C
Minus(-)
1654
60
C
Minus(-)
1166
60
Normal 1406
Normal
906
Normal 1838
54
Normal 1296
54
Plus (+)
1547
Plus (+)
997
Plus (+)
2022
49
Plus (+)
1426
49
D
Minus(-)
1628
D
Minus(-)
1049
D
Minus(-)
1690
59
D
Minus(-)
1172
59
Normal 1809
Normal 1165
Normal 1878
53
Normal 1302
53
Plus (+)
1990
Plus (+)
1282
Plus (+)
2066
48
Plus (+)
1432
48
* @ .1" - .5" w.c. ESP
Notes
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.
Gas
Altitude
Kit
Orifice
Manifold Pressure
Pressure Switch
Change
High Stage
Low Stage
Natural
0-7000 Changeover
None
#43
3.5” W.C.
1.9” W.C.
None
Propane
0-7000
LPM-03B & LPM-05
#55
10.0: W.C.
6.0” W.C.
None
• For installation in Canada, gas furnaces are certified only to 4,500 ft.
• For GCVA installations above 7,000 ft., please refer to your Goodman distributor for required kit(s).
s
taNdard
a
ltitude
i
NstallatioNs