background image

p

roduCt

 s

peCifiCatioNs

www.goodmanmfg.com 

SS-GMVC95

gmVC95 a

irflow

 d

ata

C

ooliNg

 s

peeds

GMVC950453BX

GMVC950704CX

High Stage

Low Stage

High Stage

Low Stage

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Tap

Adjust

CFM*

A

Minus(-)

540

A

Minus(-)

351

A

Minus(-)

540

A

Minus(-)

351

Normal  

600

Normal  

390

Normal  

600

Normal  

390

Plus (+)

660

Plus (+)

429

Plus (+)

660

Plus (+)

429

B

Minus(-)

720

B

Minus(-)

468

B

Minus(-)

720

B

Minus(-)

468

Normal  

800

Normal  

520

Normal  

800

Normal  

520

Plus (+)

880

Plus (+)

572

Plus (+)

880

Plus (+)

572

C

Minus(-)

900

C

Minus(-)

585

C

Minus(-)

990

C

Minus(-)

644

Normal  

1000

Normal  

650

Normal  

1100

Normal  

715

Plus (+)

1100

Plus (+)

715

Plus (+)

1210

Plus (+)

787

D

Minus(-)

1080

D

Minus(-)

702

D

Minus(-)

1286

D

Minus(-)

836

Normal  

1200

Normal  

780

Normal  

1429

Normal  

929

Plus (+)

1320

Plus (+)

858

Plus (+)

1572

Plus (+)

1022

GMVC950905CX

GMVC950905DX

High Stage

Low Stage

High Stage

Low Stage

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Tap

Adjust

CFM*

A

Minus(-)

729

A

Minus(-)

495

A

Minus(-)

720

A

Minus(-)

468

Normal  

810

Normal  

550

Normal  

800

Normal  

520

Plus (+)

891

Plus (+)

605

Plus (+)

880

Plus (+)

572

B

Minus(-)

990

B

Minus(-)

693

B

Minus(-)

900

B

Minus(-)

644

Normal  

1100

Normal  

770

Normal  

1000

Normal  

715

Plus (+)

1210

Plus (+)

847

Plus (+)

1100

Plus (+)

787

C

Minus(-)

1323

C

Minus(-)

900

C

Minus(-)

1260

C

Minus(-)

819

Normal  

1470

Normal  

1000

Normal  

1400

Normal  

910

Plus (+)

1617

Plus (+)

1100

Plus (+)

1540

Plus (+)

1001

D

Minus(-)

1629

D

Minus(-)

1125

D

Minus(-)

1620

D

Minus(-)

1053

Normal  

1810

Normal  

1250

Normal  

1800

Normal  

1170

Plus (+)

1991

Plus (+)

1375

Plus (+)

1980

Plus (+)

1287

GMVC951155DX

High Stage

Low Stage

Tap

Adjust

CFM*

Tap

Adjust

CFM*

A

Minus(-)

720

A

Minus(-)

468

Normal  

800

Normal  

520

Plus (+)

880

Plus (+)

572

B

Minus(-)

990

B

Minus(-)

644

Normal  

1100

Normal  

715

Plus (+)

1210

Plus (+)

787

C

Minus(-)

1260

C

Minus(-)

819

Normal  

1400

Normal  

910

Plus (+)

1540

Plus (+)

1001

D

Minus(-)

1620

D

Minus(-)

1053

Normal  

1800

Normal  

1170

Plus (+)

1980

Plus (+)

1287

*   @ .1" - .8" w.c. ESP

Notes:

•  All furnaces ship as high speed for cooling.  Installer must adjust blower speed as needed.
•  For most jobs, about 400 CFM per ton when cooling is desirable.
•  Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.

Содержание GCVC91155DX

Страница 1: ...et with durable baked enamel finish Foil faced insulation lines the heat exchanger Easy to install top venting is standard alternate flue vent connections on some models Designed for multi position in...

Страница 2: ...tage High E ciency Maximum CFM 0 5 ESP 3 1200 5 2000 SystemType 4 1600 C ComfortNet CommunicaRng System MBTU h AFUE 045 45 000 115 115 000 95 95 8 80 070 70 000 140 140 000 9 90 090 90 000 10 11 12 13...

Страница 3: ...4 4 Max Overcurrent Protection5 15 amps 15 amps 15 amps 15 amps 15 amps 15 amps 15 amps 15 amps Ship Weight lbs 121 145 160 160 170 139 165 160 Natural Gas BTU h DOE AFUE based upon Isolated Combustio...

Страница 4: ...or the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input number of elbows length of run and installation 1 or 2 pipes The optional Combustion Air Pipe is de...

Страница 5: ...ailable Contact your Goodman distributor or dealer for details Installer must supply following gas line fittings according to which entrance is used Left Two 90 elbows one close nipple straight pipe R...

Страница 6: ...68 Normal 810 Normal 550 Normal 800 Normal 520 Plus 891 Plus 605 Plus 880 Plus 572 B Minus 990 B Minus 693 B Minus 900 B Minus 644 Normal 1100 Normal 770 Normal 1000 Normal 715 Plus 1210 Plus 847 Plus...

Страница 7: ...458 55 Normal 1 050 1 490 54 Normal 1 125 1 620 50 Plus 1 155 1 639 49 Plus 1 238 1 782 45 B Minus 1 008 1 413 57 B Minus 1 076 1 549 52 Normal 1 120 1 570 51 Normal 1 195 1 721 47 Plus 1 232 1 727 4...

Страница 8: ...915DX Cooling Speeds GCVC950915DX Heating Speeds Rise Range 25 55 F High Stage Low Stage High Stage Low Stage Tap Adjust CFM Tap Adjust CFM Tap Adjust CFM Rise Tap Adjust CFM Rise A Minus 729 A Minus...

Страница 9: ...lus 1970 50 Plus 1352 50 C Minus 1265 C Minus 815 C Minus 1654 60 C Minus 1166 60 Normal 1406 Normal 906 Normal 1838 54 Normal 1296 54 Plus 1547 Plus 997 Plus 2022 49 Plus 1426 49 D Minus 1628 D Minus...

Страница 10: ...Valve Wiring is subject to change Always refer to the wiring diagram or the unit for the most up to date wiring WARNING High Voltage Disconnect all power before servicing or installing this unit Multi...

Страница 11: ...DULE 3 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C USE COPPER CONDUCTORS ONLY PU DI...

Страница 12: ...Springs Orifice 1 1 1 1 1 1 1 LPM 06 LP Conversion Kit Springs Orifice 1 1 1 1 1 1 1 GSAS Electronic Air Cleaners 10 11 12 or 18 GMU Media Air Cleaners 1620 2020 1625 or 2025 DEHUM1 Dehumidistat HAPS...