background image

p

roduCt

 s

peCifiCatioNs

www.goodmanmfg.com 

SS-GMVC95

gCVC95 a

irflow

 d

ata

GCVC950714CX

Cooling Speeds

GCVC950714CX

Heating Speeds (Rise Range:  25 - 55°F)

High Stage

Low Stage

High Stage

Low Stage

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Rise

Tap

Adjust

CFM*

Rise

A

Minus

594

A

Minus

324

A

Minus

1107

55

A

Minus

783

77

Normal

660

Normal

360

Normal

1230

49

Normal

870

69

Plus

726

Plus

396

Plus

1353

45

Plus

957

63

B

Minus

747

B

Minus

468

B

Minus

1215

50

B

Minus

855

71

Normal

830

Normal

520

Normal

1350

45

Normal

950

64

Plus

913

Plus

572

Plus

1485

41

Plus

1045

58

C

Minus

1017

C

Minus

702

C

Minus

1323

46

C

Minus

936

65

Normal

1130

Normal

780

Normal

1470

41

Normal

1040

58

Plus

1243

Plus

858

Plus

1617

37

Plus

1144

53

D

Minus

1314

D

Minus

864

D

Minus

1440

42

D

Minus

1017

59

Normal

1460

Normal

960

Normal

1600

38

Normal

1130

53

Plus

1606

Plus

1056

Plus

1760

34

Plus

1243

49

*   @ .1" - .5" w.c. ESP

GCVC950915DX

Cooling Speeds

GCVC950915DX

Heating Speeds (Rise Range:  25 - 55°F)

High Stage

Low Stage

High Stage

Low Stage

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Tap

Adjust

CFM*

Rise

Tap

Adjust

CFM*

Rise

A

Minus

729

A

Minus

504

A

Minus

1458

55

A

Minus

1008

80

Normal

810

Normal

560

Normal

1620

50

Normal

1120

72

Plus

891

Plus

616

Plus

1782

45

Plus

1232

65

B

Minus

999

B

Minus

666

B

Minus

1575

51

B

Minus

1098

73

Normal

1110

Normal

740

Normal

1750

46

Normal

1220

66

Plus

1221

Plus

814

Plus

1925

42

Plus

1342

60

C

Minus

1287

C

Minus

828

C

Minus

1674

48

C

Minus

1152

70

Normal

1430

Normal

920

Normal

1860

43

Normal

1280

63

Plus

1573

Plus

1012

Plus

2046

39

Plus

1408

57

D

Minus

1674

D

Minus

1071

D

Minus

1773

45

D

Minus

1206

67

Normal

1860

Normal

1190

Normal

1970

41

Normal

1340

60

Plus

2046

Plus

1309

Plus

2167

37

Plus

1474

55

*   @ .1" - .5" w.c. ESP

Notes

•  All furnaces ship as high speed for cooling.  Installer must adjust blower speed as needed.
•  For most jobs, about 400 CFM per ton when cooling is desirable.
•  Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.

Содержание GCVC91155DX

Страница 1: ...et with durable baked enamel finish Foil faced insulation lines the heat exchanger Easy to install top venting is standard alternate flue vent connections on some models Designed for multi position in...

Страница 2: ...tage High E ciency Maximum CFM 0 5 ESP 3 1200 5 2000 SystemType 4 1600 C ComfortNet CommunicaRng System MBTU h AFUE 045 45 000 115 115 000 95 95 8 80 070 70 000 140 140 000 9 90 090 90 000 10 11 12 13...

Страница 3: ...4 4 Max Overcurrent Protection5 15 amps 15 amps 15 amps 15 amps 15 amps 15 amps 15 amps 15 amps Ship Weight lbs 121 145 160 160 170 139 165 160 Natural Gas BTU h DOE AFUE based upon Isolated Combustio...

Страница 4: ...or the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input number of elbows length of run and installation 1 or 2 pipes The optional Combustion Air Pipe is de...

Страница 5: ...ailable Contact your Goodman distributor or dealer for details Installer must supply following gas line fittings according to which entrance is used Left Two 90 elbows one close nipple straight pipe R...

Страница 6: ...68 Normal 810 Normal 550 Normal 800 Normal 520 Plus 891 Plus 605 Plus 880 Plus 572 B Minus 990 B Minus 693 B Minus 900 B Minus 644 Normal 1100 Normal 770 Normal 1000 Normal 715 Plus 1210 Plus 847 Plus...

Страница 7: ...458 55 Normal 1 050 1 490 54 Normal 1 125 1 620 50 Plus 1 155 1 639 49 Plus 1 238 1 782 45 B Minus 1 008 1 413 57 B Minus 1 076 1 549 52 Normal 1 120 1 570 51 Normal 1 195 1 721 47 Plus 1 232 1 727 4...

Страница 8: ...915DX Cooling Speeds GCVC950915DX Heating Speeds Rise Range 25 55 F High Stage Low Stage High Stage Low Stage Tap Adjust CFM Tap Adjust CFM Tap Adjust CFM Rise Tap Adjust CFM Rise A Minus 729 A Minus...

Страница 9: ...lus 1970 50 Plus 1352 50 C Minus 1265 C Minus 815 C Minus 1654 60 C Minus 1166 60 Normal 1406 Normal 906 Normal 1838 54 Normal 1296 54 Plus 1547 Plus 997 Plus 2022 49 Plus 1426 49 D Minus 1628 D Minus...

Страница 10: ...Valve Wiring is subject to change Always refer to the wiring diagram or the unit for the most up to date wiring WARNING High Voltage Disconnect all power before servicing or installing this unit Multi...

Страница 11: ...DULE 3 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C USE COPPER CONDUCTORS ONLY PU DI...

Страница 12: ...Springs Orifice 1 1 1 1 1 1 1 LPM 06 LP Conversion Kit Springs Orifice 1 1 1 1 1 1 1 GSAS Electronic Air Cleaners 10 11 12 or 18 GMU Media Air Cleaners 1620 2020 1625 or 2025 DEHUM1 Dehumidistat HAPS...

Отзывы: