p
rodUCT
s
peCiFiCaTions
p
rodUCT
s
peCiFiCaTions
2 www.goodmanmfg.com
SS-CPG180-240
n
omenClaTUre
C
P
G
180
060
3
B
*
*
*
A
*
1
2
3
4,5,6
7,8,9
10
11
12
13
14
15 16
Revision Levels
Major & Minor
Brand
Factory-‐Installed Op7ons
C
Commercial
X
No OpCons
A
Non-‐powered convenience outlet
Configura7on
B
Powered convenience outlet
P
Packaged Unit
C
Low-‐ambient kit
F
Non-‐powered convenience outlet;
Applica7on
Low-‐ambient kit
C
Cooling
M Powered convenience outlet;
G
Gas Heat
Low-‐ambient kit
H
Heat Pump
Factory-‐Installed Op7ons
Nominal Gross Cooling Capacity
X
Standard Aluminized Heat Exchanger
036 3 Tons
102
8½ Tons
A
Condenser Coil Hail Guard
048 4 Tons
120
10 Tons
B
Condenser Coil Hail Guard
060 5 Tons
150
12½ tons
Treated Condenser Coil (UltraGold)
072 6 Tons
180 & 181 15 Tons
C
Condenser Coil Hail Guard
090 7½ Tons
240
20 Tons
Stainless Steel Heat Exchanger
D
Condenser Coil Hail Guard
Nominal Hea7ng Capacity
Treated Condenser Coil (UltraGold)
CPG
CPC/CPH (Factory-‐Installed Electric Heat)
Stainless-‐Steel Heat Exchanger
045 45,000 BTU/h
XXX No Heat
J
Treated Condenser Coil (UltraGold)
090 90,000 BTU/h
010 10 kW
030 30 kW
S
Stainless-‐Steel Heat Exchanger
115 115,000 BTU/h
015 15 kW
031 30 kW
T
Treated Condenser Coil (UltraGold)
140 140,000 BTU/h
016 15 kW
045 45 kW
Stainless-‐Steel Heat Exchanger
210 210,000 BTU/h
018 18 kW
046 45 kW
350 350,000 BTU/h
020 20 kW
060 60 kW
Factory-‐Installed Op7ons
400 400,000 BTU/h
025 25 kW
075 75 kW
X
No OpCons
A
Downflow Economizer
Voltage
Supply Fan/Drive Type/Motors
1
208-‐230/1/60
4 460/3/60
B
Belt Drive
3
208-‐230/3/60
7 575/3/60
D
Direct Drive
H
High-‐StaCc Belt Drive (Factory-‐Installed)
Note: Not all opCons available for all products.
Factory-‐Installed Op7ons
•
Condenser Hail Guards: Louvered metal guards help protect the condenser coil from damage from hail and debris. Available as a factory-‐installed
opCon on 3-‐ to 12½-‐ton units. Hail guards are standard on 15-‐ and 20-‐ton units.
•
Stainless-‐Steel Heat Exchanger (CPG units only): A tubular heat exchanger made of 409-‐type stainless steel is installed in the unit.
•
Ultra-‐Gold Condenser Coil: Offers increased corrosion resistance of the condenser coil. Not available for 15-‐ & 20-‐ton units.
•
Low-‐Ambient Kit: Allows for cooling operaCon at lower outdoor temperatures. On the 3-‐ to 6-‐ton units, cooling operaCon is extended from 60°F
ambient temperature to 35°F outside air temperature. On 7½-‐ to 20-‐ton units, cooling operaCon is extended from 35°F ambient temperature
to 0°F outside air temperature.
•
Economizers (Downflow): Based on air condiCons, can provide outside air to cool the space.
•
High StaCc Kits: Provides airflow in higher staCc applicaCons.
•
Electric Heat Kits (CPC and CPH units only): Available in all voltage opCons.
•
Non-‐powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs power
to the outlet.
•
Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit.