Goodman ASAS-10ASC Скачать руководство пользователя страница 4

 

UNIT 

ASAS-10ASC 
GSAS-10ASC 

21 

(53.0) 

17 

(43.5) 

23 1/4 

(59.0) 

13 1/8 

(33.5) 

20 3/4 

(53.0) 

1 1/4 

(3.0) 

23 3/4 

(60.5) 

2 3/8 

(6.0) 

ASAS-11ASC 
GSAS-11ASC 

21 

(53.0) 

17 

(43.5) 

26 

(66.0) 

13 5/8 

(34.5) 

24 

(61.0) 

(2.5) 

26 1/2 

(67.5) 

2 1/8 

(5.5) 

ASAS-12ASC 
GSAS-12ASC 

25 7/8 

(66.0) 

22 

(56.0) 

21 1/4 

(54.0) 

18 

(46.0) 

18 3/4 

(47.5) 

1 1/4 

(3.0) 

21 3/4 

(55.0) 

2 3/8 

(6.0) 

ASAS-18ASC 
GSAS-18ASC 

25 7/8 

(66.0) 

22 

(56.0) 

26 

(66.0) 

18 

(46.0) 

23 1/2 

(59.5) 

1 1/4 

(3.0) 

26 1/2 

(67.5) 

2 3/8 

(6.0) 

DIMENSIONS — in  (cm)  

3.  Place cabinet in ductwork. Holes are provided to 

attach cabinet to ductwork or equipment. If 
adjoining ductwork is flanged, install the screws so 
that screw heads are inside cabinet. This will help 
prevent damage to prefilter and carbon filters 
during removal for cleaning. NEVER put screws or 
rivets into the removable power box.  
When the air duct does not fit Air Cleaner opening, 
a gradual transition is recommended to reduce air 
turbulence through Air Cleaner and to increase its 
efficiency. There should not be more than 20º of 
expansion used on each side of transition fitting. 
Do not reduce ductwork to a smaller Air Cleaner or 
it will increase velocity of airflow. 

4.  If Air Cleaner is installed adjacent to an elbow or 

angle fitting, turning vanes are recommended to 
improve air distribution across the collecting cells. 

5.  After Air Cleaner has been secured, seal seams 

airtight with duct tape or caulking to prevent dust 
from entering the system. 

6.  Replace prefilters, collecting cells and carbon 

filters. Make sure arrow on cell is pointing towards 
the fan. The cell handle may need to be 
repositioned if the airflow is in a different direction 
than the left to right set up. The handle should face 
the door. Close access door. 

Fig. 4 — AIR CLEANER INSTALLATION LOCATION 

Allow 24 in (600 mm) clearance for cleaning air cleaner.  Allow 6 in. (150 mm) clearance for power box removal. 

Fig. 3 — DIMENSIONS 

Performance Indicator 
Light 
 
 
 
 
Air Proving Switch 
 
Handle 
 
 
Door 

Power Switch 
 
 

AIR FLOW            

Î

 

Left to Right or 
Right to Left 

Содержание ASAS-10ASC

Страница 1: ...eria and more down to 0 01 micron Light Weight Aluminum Collecting Cells are durable and easy to maintain Cell Guides ensure proper placement of collecting cells Activated Carbon Filters remove unplea...

Страница 2: ...precautions that may apply Follow all safety codes Wear safety glasses and work gloves WHAT THE ELECTRONIC AIR CLEANER DOES Your High Efficiency Electronic Air Cleaner has been designed to remove atmo...

Страница 3: ...ng Installation Location With Humidifier A humidifier should be installed in the furnace warm air duct However it may be installed in the return duct without causing problems to the Air Cleaner Care m...

Страница 4: ...air turbulence through Air Cleaner and to increase its efficiency There should not be more than 20 of expansion used on each side of transition fitting Do not reduce ductwork to a smaller Air Cleaner...

Страница 5: ...irflow through the ducts The Air Cleaner will not run if the system fan is off For proper operation follow these simple steps 1 Run heating cooling system fan continuously and on low speed if availabl...

Страница 6: ...low Replacement Carbon Filters A GSAS 10 A GSAS 11 Set of 3 Part 1156 3 A GSAS 12 A GSAS 18 Set of 3 Part 1856 3 SERVICE Testing Air Proving Switch APS The APS sensor must protrude through the plastic...

Страница 7: ...aner at the source 1 Remove the power box cover 2 Disconnect the performance light wiring connected to the LED terminals on the power board 3 Push the light out through the front of the power box 4 Pu...

Страница 8: ...se proximity to hydro towers or situated in remote farm land areas By adjusting the HV ADJ potentiometer the voltage can be set to optimum level A high voltage meter capable of measuring 10 000 VDC is...

Страница 9: ...t Look along the top of the cell with the short still in place If there is a small arc between the cell top and copper contact then that is the bad contact Pull cell out and gently pull copper contact...

Страница 10: ...4 Using needle nose pliers place spring hook in the hole of the ionizing bar near cell top 5 Place eyelet of wire over the S hook and place S hook into hole on ionizing bar on other side of cell Keep...

Страница 11: ...icle out of cell Replace wire if necessary Ducts were not cleaned prior to installation of air cleaner Clean ducts Cell plate s are bent Remove cells and adjust to original spacing using needle nose p...

Страница 12: ...BUT NOT LIMITED TO LOSSES TO PERSONS OR PROPERTY ARISING OUT OF THE FAILURE OF THIS EQUIPMENT TO OPERATE FOR ANY REASON WHATSOEVER ARE EXCLUDED THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLU...

Отзывы: