Replacing A Tungsten Ionizing Wire
Replacement wires are cut to the correct length
and have eyelets at each end for easy replacement.
1. Turn OFF power to Air Cleaner.
2. Remove cell from Air Cleaner.
3. Remove all parts of broken wire, as well as spring
and S-hook. If necessary, cell may be used
temporarily with one wire missing until a
replacement is received.
4. Using needle-nose pliers, place spring hook in the
hole of the ionizing bar near cell top.
5. Place eyelet of wire over the S-hook and place S-
hook into hole on ionizing bar on other side of cell.
Keep wire tight to ensure S-hook remains in hole.
6. Using the needle-nose pliers, grab the end of the
spring and stretch towards loop in wire. Place
eyelet in wire over spring hook and release spring.
See Fig. 11.
7. Install cell in Air Cleaner.
8. Return power to Air Cleaner.
9. Test cell for proper operation.
Fig. 11 — Replacing An Ionizing Wire
Ionizing Bar
Spring
Wire