1 Dirty Air
2 Prefilter
3 Ionizing
Section
COMPONENTS
Cabinet:
Constructed of heavy gauge galvanized
steel to resist corrosion and provide trouble-free
installation. Holes are provided to facilitate mounting to
the ductwork or air handling equipment.
Power Box:
Removable. Contains the power switch,
performance indicator light, safety interlock switch,
high voltage power board and air proving switch.
The power board is uniquely equipped with a variable
resistor (potentiometer) to adjust high voltage output.
Output has been pre-set for optimum efficiency. As
voltage varies in extreme conditions of dryness,
humidity or proximity to hydro towers, raising or
lowering potentiometer allows for proper voltage
output.
Air Proving Switch (APS):
Integrated. Automatically
cycles Air Cleaner on and off with the system fan. The
APS will detect airflow (fan on) and energize Air
Cleaner.
High Voltage Tray:
Contains the contacts and wires to
supply high voltage to the collecting cells.
Collecting Cells:
Consist of an ionizing section and a
plate section. The arrow on the cell must point toward
the system fan.
Prefilters:
Constructed of aluminum mesh, to prevent
lint and large particles from entering the collecting
cells.
Carbon Filters:
Remove odors. Must be replaced
every six months - not washable. Maximum of (3)
carbon filters can be used at same time.
INSTALLATION
Location
The Air Cleaner must be installed in the return air
duct, as close to the fan compartment as possible. This
location provides the most even airflow across the
collecting cells and allows the Air Cleaner to keep the
system motor and blower clean. When choosing
location, there must be adequate room to wire the Air
Cleaner and remove prefilters, collecting cells and
power box.
Note:
Once Air Cleaner has been installed, do not
allow the placement of any device such as a new hot
water heater, water softener, gas pipe, or electrical
cable to be put 2 ft. in front of or within 6 in. (15 cm)
from top of Air Cleaner, in order to allow removal of
filters and Air Cleaner parts, which are necessary for
maintenance or servicing.
Installation Location With Humidifier
A humidifier should be installed in the furnace
warm air duct. However, it may be installed in the
return duct without causing problems to the Air
Cleaner. Care must be taken to ensure that the
humidifier does not leak, as this may cause arcing and
a mineral deposit to build up on the collecting cells.
An atomizing type humidifier should be installed
downstream from the Air Cleaner. If the atomizing type
humidifier is installed upstream, high humidity, salts
and minerals may decrease the efficiency of the
collecting cells and cause service problems.
If the atomizing type humidifier must be installed
upstream, the following precautions should be taken:
1. Atomizing type humidifier must be installed as far
from the Air Cleaner as possible.
2. Collecting cells must be washed frequently to
prevent a mineral deposit build-up.
Installation Location With Air Conditioner
Whenever possible, the Air Cleaner should be
installed upstream of the cooling coil. This location will
clean the air before it reaches the evaporator coil.
Electronic Air Cleaner Installation
1. Remove existing equipment filter. Thoroughly
clean fan compartment and ductwork where Air
Cleaner is to be installed.
2. Open access door. Slide prefilters and collecting
cells out of cabinet.
4 Collecting Cell Plates
5 Carbon Filters (3)
6 Clean Air to Heating/Cooling
System
MODEL
A/ GSAS-10ASC
A/ GSAS-11ASC
A/ GSAS-12ASC
A/ GSAS-18ASC
House Size Area
<2400 ft²
<222.96 m²
<3000 ft²
<278.70 m²
<3000 ft²
<278.70 m²
>3000 ft²
>278.70 m²
Airflow
up to 1200 cfm
up to 2039 m³/hr
up to 1400 cfm
up to 2379 m³/hr
up to 1400 cfm
up to 2379 m³/hr
up to 2000 cfm
up to 3398 m³/hr
Duct Size
16 x 20 in
40.5 x 51.0 cm
16 x 25 in
40.5 x 63.5 cm
20 x 20 in
51.0 x 51.0 cm
20 x 25 in
51.0 x 63.5 cm
Unit Weight
28.0 lbs
12.9 kg
30.0 lbs
13.5 kg
33.0 lbs
15.3 kg
38.0 lbs
17.5 kg
Input Voltage
120 v 60 hz
120 v 60 hz
120 v 60 hz
120 v 60 hz
Power Consumption
30 Watts
30 Watts
30 Watts
30 Watts
Upgrades Included
Carbon Filters (C)
Air Switch (AS)
Carbon Filters (C)
Air Switch (AS)
Carbon Filters (C)
Air Switch (AS)
Carbon Filters (C)
Air Switch (AS)
Table 1 — SPECIFICATIONS
Fig. 1
Power Box
Cabinet
Door
Fig. 2
Activated
Carbon Filters
Performance Indicator Light
ON/OFF Switch
Prefilters (2)
Collecting Cells (2)