        1 Dirty Air 

 

 

 

2 Prefilter 

 

 

        3 Ionizing

 

           Section 

 

COMPONENTS 

Cabinet:

  Constructed of heavy gauge galvanized 

steel to resist corrosion and provide trouble-free 
installation. Holes are provided to facilitate mounting to 
the ductwork or air handling equipment. 

Power Box:

  Removable. Contains the power switch, 

performance indicator light, safety interlock switch, 
high voltage power board and air proving switch. 
The power board is uniquely equipped with a variable 
resistor (potentiometer) to adjust high voltage output. 
Output has been pre-set for optimum efficiency. As 
voltage varies in extreme conditions of dryness, 
humidity or proximity to hydro towers, raising or 
lowering potentiometer allows for proper voltage 
output. 

Air Proving Switch (APS): 

 Integrated. Automatically 

cycles Air Cleaner on and off with the system fan. The 
APS will detect airflow (fan on) and energize Air 
Cleaner. 

High Voltage Tray:

 Contains the contacts and wires to 

supply high voltage to the collecting cells. 

Collecting Cells:

  Consist of an ionizing section and a 

plate section. The arrow on the cell must point toward 
the system fan. 

Prefilters:

  Constructed of aluminum mesh, to prevent 

lint and large particles from entering the collecting 
cells. 

Carbon Filters:

  Remove odors. Must be replaced 

every six months - not washable. Maximum of (3) 
carbon filters can be used at same time. 

 
 

 
 

 
 
 

 

INSTALLATION 

Location 

The Air Cleaner must be installed in the return air 

duct, as close to the fan compartment as possible. This 
location provides the most even airflow across the 
collecting cells and allows the Air Cleaner to keep the 
system motor and blower clean. When choosing 
location, there must be adequate room to wire the Air 
Cleaner and remove prefilters, collecting cells and 
power box. 

Note: 

 Once Air Cleaner has been installed, do not 

allow the placement of any device such as a new hot 
water heater, water softener, gas pipe, or electrical 
cable to be put 2 ft. in front of or within 6 in. (15 cm) 
from top of Air Cleaner, in order to allow removal of 
filters and Air Cleaner parts, which are necessary for 
maintenance or servicing. 

Installation Location With Humidifier 

A humidifier should be installed in the furnace 

warm air duct. However, it may be installed in the 
return duct without causing problems to the Air 
Cleaner. Care must be taken to ensure that the 
humidifier does not leak, as this may cause arcing and 
a mineral deposit to build up on the collecting cells. 

An atomizing type humidifier should be installed 

downstream from the Air Cleaner. If the atomizing type 
humidifier is installed upstream, high humidity, salts 
and minerals may decrease the efficiency of the 
collecting cells and cause service problems. 

If the atomizing type humidifier must be installed 

upstream, the following precautions should be taken: 
1.  Atomizing type humidifier must be installed as far 

from the Air Cleaner as possible. 

2.  Collecting cells must be washed frequently to 

prevent a mineral deposit build-up. 

Installation Location With Air Conditioner 

Whenever possible, the Air Cleaner should be 

installed upstream of the cooling coil. This location will 
clean the air before it reaches the evaporator coil. 

Electronic Air Cleaner Installation 

1. Remove existing equipment filter. Thoroughly 

clean fan compartment and ductwork where Air 
Cleaner is to be installed. 

2.  Open access door. Slide prefilters and collecting 

cells out of cabinet. 

 

4 Collecting Cell Plates 
 
5 Carbon Filters (3) 

 
 

6 Clean Air to Heating/Cooling 
   System 

MODEL 

A/ GSAS-10ASC 

A/ GSAS-11ASC 

A/ GSAS-12ASC 

A/ GSAS-18ASC 

House Size Area 

<2400 ft² 

<222.96 m² 

<3000 ft² 

<278.70 m² 

<3000 ft² 

<278.70 m² 

>3000 ft² 

>278.70 m² 

Airflow 

up to 1200 cfm 

up to 2039 m³/hr 

up to 1400 cfm 

up to 2379 m³/hr 

up to 1400 cfm 

up to 2379 m³/hr 

up to 2000 cfm 

up to 3398 m³/hr 

Duct Size 

16 x 20 in 

40.5 x 51.0 cm 

16 x 25 in 

40.5 x 63.5 cm 

20 x 20 in 

51.0 x 51.0 cm 

20 x 25 in 

51.0 x 63.5 cm 

Unit Weight 

28.0 lbs 

12.9 kg 

30.0 lbs 

13.5 kg 

33.0 lbs 

15.3 kg 

38.0 lbs 

17.5 kg 

Input Voltage 

120 v  60 hz 

120 v  60 hz 

120 v  60 hz 

120 v  60 hz 

Power Consumption 

30 Watts 

30 Watts 

30 Watts 

30 Watts 

Upgrades Included 

Carbon Filters (C) 

Air Switch (AS) 

Carbon Filters (C) 

Air Switch (AS) 

Carbon Filters (C) 

Air Switch (AS) 

Carbon Filters (C) 

Air Switch (AS) 

Table 1 — SPECIFICATIONS 

Fig. 1 

Power Box 

Cabinet 

Door 

Fig. 2 

Activated 

Carbon Filters 

Performance Indicator Light 

ON/OFF Switch 

Prefilters (2) 

Collecting Cells (2) 

Содержание ASAS-10ASC

Страница 1: ...eria and more down to 0 01 micron Light Weight Aluminum Collecting Cells are durable and easy to maintain Cell Guides ensure proper placement of collecting cells Activated Carbon Filters remove unplea...

Страница 2: ...precautions that may apply Follow all safety codes Wear safety glasses and work gloves WHAT THE ELECTRONIC AIR CLEANER DOES Your High Efficiency Electronic Air Cleaner has been designed to remove atmo...

Страница 3: ...ng Installation Location With Humidifier A humidifier should be installed in the furnace warm air duct However it may be installed in the return duct without causing problems to the Air Cleaner Care m...

Страница 4: ...air turbulence through Air Cleaner and to increase its efficiency There should not be more than 20 of expansion used on each side of transition fitting Do not reduce ductwork to a smaller Air Cleaner...

Страница 5: ...irflow through the ducts The Air Cleaner will not run if the system fan is off For proper operation follow these simple steps 1 Run heating cooling system fan continuously and on low speed if availabl...

Страница 6: ...low Replacement Carbon Filters A GSAS 10 A GSAS 11 Set of 3 Part 1156 3 A GSAS 12 A GSAS 18 Set of 3 Part 1856 3 SERVICE Testing Air Proving Switch APS The APS sensor must protrude through the plastic...

Страница 7: ...aner at the source 1 Remove the power box cover 2 Disconnect the performance light wiring connected to the LED terminals on the power board 3 Push the light out through the front of the power box 4 Pu...

Страница 8: ...se proximity to hydro towers or situated in remote farm land areas By adjusting the HV ADJ potentiometer the voltage can be set to optimum level A high voltage meter capable of measuring 10 000 VDC is...

Страница 9: ...t Look along the top of the cell with the short still in place If there is a small arc between the cell top and copper contact then that is the bad contact Pull cell out and gently pull copper contact...

Страница 10: ...4 Using needle nose pliers place spring hook in the hole of the ionizing bar near cell top 5 Place eyelet of wire over the S hook and place S hook into hole on ionizing bar on other side of cell Keep...

Страница 11: ...icle out of cell Replace wire if necessary Ducts were not cleaned prior to installation of air cleaner Clean ducts Cell plate s are bent Remove cells and adjust to original spacing using needle nose p...

Страница 12: ...BUT NOT LIMITED TO LOSSES TO PERSONS OR PROPERTY ARISING OUT OF THE FAILURE OF THIS EQUIPMENT TO OPERATE FOR ANY REASON WHATSOEVER ARE EXCLUDED THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLU...