PRODUCT IDENTIFICATION
8
MODEL #
MFG #
DESCRIPTION
AFE18-60A
N/A
Fossil Fuel Kit.
The AFE18-60A control is designed for use where the indoor coil is located
above/downstream of a gas or fossil fuel furnace when used with a heat pump. It will
operate with single and two stage heat pumps and single and two stage furnaces. The
AFE18-60A control will turn the heat pump unit off when the furnace is turned on. An anti-
short cycle feature initiates a 3 minute timed off delay when the compressor goes off.
AMU1620
AMU1625
AMU2020
AMU2025
GMU1620
GMU1625
GMU2020
GMU2025
P1251305F
P1251306F
P1251307F
P1251308F
N/A
Media Air Cleaner
. The Amana (AMU*) and Goodman (GMU*) Media Air Cleaner is a high
efficiency air filtration device designed to remove dirt, dust, pollen and other microscopic
particles from the air passing through it. Flexible performance range up to 2,000 CFM
capacity. The air cleaner should be installed in the system so that all the system air is
circulated through the air cleaner. The air cleaner will only remove the airborne
contaminants delivered to it. Maximum performance is obtained when the system blower
is set for continuous operation. Carbon filters (optional) are available.
ASAS-10
ASAS-11
ASAS-12
ASAS-18
P1251301F
P1251302F
P1251303F
P1251304F
Electronic Air Cleaner
. The High-Efficiency Electronic Air Cleaner is designed to remove
air contaminants down to .01 microns. Carbon filters (optional) remove odors. Dual
indicator lights show unit operation at a glance. Electronic proving switch cycles the air
cleaner On/Off with the system fan. Durable powder-coat paint finish resists corrosion.
DCVK-20
DCVK-30
P1254001F
P1254002F
Concentric Vent Kit
. For use with Amana® Brand high efficiency furnace models
.
This kit
is designed to allow terminations of a direct vent furnace to be "concentrically" vented
through a wall or roof. This kit allows a single penetration to support terminations for both
the vent/flue and the combustion air intake pipe. The DCVK-20 (2") and DCVK-30 (3") kits
are certified for models listed above. See specification sheets on future models for use of
the vent kit.
0170K00000S
N/A
Side Wall Only Concentric Vent Kit
. For use with high efficiency furnace models
.
This kit
is to be used with 2" - 3" vent systems. The vent kit must terminate outside the structure.
This kit is NOT intended for use with single pipe (indirect vent) installations.
0170K00001S
N/A
Side Wall Only Concentric Vent Kit
. For use with high efficiency 90% furnace models
.
This kit is to be used with 2" only vent systems. The vent kit must terminate outside the
structure. This kit is NOT intended for use with single pipe (indirect vent) installations.
EFR02
P1221001
P1221002F
External Filter Rack Kit
. This kit is intended to provide a location, external to the furnace
casing, for installation of a permanent filter. The rack is mounted over the indoor air
blower compartment area of either side panel, and provide filter retention as well as a
location for attaching return air ductwork.
LPLP03
N/A
LP Gas Low Pressure Kit
. Designed for application on Goodman® and Amana® Brand's
80% and 90% single-stage and two-stage gas fired furnace products installed on LP gas
listed in this manual. This kit includes harness adaptors to work with White-Rodgers
single & two stage gas valves,Honeywell single and two-stage gas valves, as well as
modulating gas valves.
RF000142
N/A
Vent Drain Coupling
. For use when the furnaces is installed in horizontal left position and
the internal elbow is removed.