GONSIN DCS-3021 Скачать руководство пользователя страница 14

1

Battery capacity detection

2

Low-voltage alarm and automatic shutdown

3

Hold and press the MIC button on the MIC 

base

 to turn on/off the terminal

4

RUN indicator

5

Attendance registration by button pressing or prosthesis registration

6

Speaking mode: AUTO or FIFO; hear a speaker via the headphone or built-in loudspeaker; volume is adjustable

 

7

Automatic video tracking and panoramic preset position; in support of SD and HD video tracking

8

Micro USB interface for charging; lithium battery is removable for batch charging

13

Front side: 

5

3.5mm jack

Headphone output interface with a 

3.5mm jack

1

Microphone gooseneck

6

3.5mm jack

Audio output interface with a 3.5mm 

2

Priority key (red)

jack

7

Volume knob

Bottom:

Press this key to close all active 

delegate

 terminals. 

This key is available for the chairman terminal only. 

9. terminal number setting: Like the dial-up setting, the

3

MIC ON/OFF key

defaut is dialing up, namely 00000000.

8

Indicator Light; it blinks when the congress terminal 

Function description: host ID is a code used within a
system for internal communication. Communication
can be successful only when the host ID of the
system is consistent with that of a congress terminal.

is matching with the congress server, it 

keeps lights on

 

when the congress terminal matches with the congress 
server successfully. It lights green with sufficient 
power, otherwise it would light red. 

Within a building, set different host IDs for multiple

Left side: 

wireless congress systems to avoid mutual

4

Micro USB interface for charging; the lithium 

interference.

batteries can be removed and charged in batch. 

Chapter 3 Compositions of the Wireless Conference System

3

.

1

 

Functions and Indicators of the Wireless Congress Terminal

3.1.1 Overview

The congress terminal is essential for a conference participant and it connects with a congress server via the 
wireless AP. Functions available to participants vary with the type of a conference unit, including listening, 
speaking, and requesting to speak. 

Product models: 

DCS-3021C-W           Chairman terminal with basic discussion

DCS-3021D-W           Delegate terminal with basic discussion

3.1.2

 

Basic Functions

3.1.3

 

Basic Functions

3.2 Functions and Indicators of Wireless AP

The wireless AP can transmit signal and is the transit device between the GONSIN30000 server and DSC-
3021congress terminals. The device utilizes the advanced selecting-hopping technology. The wireless AP has 
super-strong emissivity and anti-interference capacity. It can transmit at all directions and is immune to any 
obstacle. 

Notice: one congress server can be connected with one wireless AP. At the same time. The system can connected 
with WAP-30I wireless simultaneous interpretation AP in order to realize the simultaneous interpretation function. 
The system is recommended to use in the medium or small conference room.

14

Product model: 

WAP-30

3.2.1 Basic Functions

1

RUN indicator

2

Powered by the congress server

3

Wall mounting, bracket supporting, and ceiling mounting

3.2.2 Indicators

1.Signal indicator (when a microphone is connected to the wireless access point, this indicator will flash)

2.6P socket, for connecting with WAP-30I (for adding listening and simultaneous interpretation functions)

3.8P socket, for connecting with WAP-30( discussion function only) 

Lateral 

DCS-3021 Congress System

Buttom

Front

Back

2

3

1

Содержание DCS-3021

Страница 1: ...DCS 3021 Conference System User Manual...

Страница 2: ...ndicators 13 3 2 Functions and Indicators of Wireless AP 14 3 2 1 Basic Functions 14 3 2 2 Indicators 14 3 2 3 WAP 30 15 3 3 Functions and Indicators of Charging Case 15 3 3 1 Basic Functions 15 3 3 2...

Страница 3: ...02 DCS 3021 Congress System Chapter 8 FAQs Appendix 25 24...

Страница 4: ...ent Select proper package or original card serves as a basis for future maintenance package for transportation free of charge 9 Keep the equipment room ventilated so as to prolong the service life of...

Страница 5: ...attery may be damaged resulting in fire or explosion Do not set the battery in water or moisten the battery anode cathode otherwise the battery will be corroded and heated up resulting in leakage fire...

Страница 6: ...tenance does not need much skill as well technicians can operate the terminal after a short period of training System composition The DCS congress system is composed of the congress server wireless co...

Страница 7: ...10mm Pluggable Microphone Stem Black MIC 410 14 5 Y 410mm Pluggable Microphone Stem Black MIC 510 14 5 Y 510mm Pluggable Microphone Stem Black MIC 310 14 5 Y 310mm Pluggable Microphone Stem Silver MIC...

Страница 8: ...Functions and Indicators 2 2 1 Basic Functions 1 Use 2 4GHz frequency hopping technology to automatically detect 2 4GHz RF resources and use reliable frequency hopping mechanism to avoid co channel in...

Страница 9: ...ne channel 6P interface This interface is used for connecting to WAP 30I for increasing the 3 Operation buttons up down left right arrow buttons number of listening units and simultaneous 4 OK button...

Страница 10: ...nector connects the male connector of 8P2 01 male male connector cable the other male connector of 8P2 01 connects to the female connector of WAP 30 AP as shown in the following figure 2 4 2 Connectio...

Страница 11: ...ng to the congress server power of the camera is supplied directly from the control room One group is the HD video wiring which is implemented by connecting the video output of the dome camera to the...

Страница 12: ...er to 485 and 485 of central control unit Please note that the RS485 control cable of dome camera is already connected with RS485 control cable of central control unit The control cable of dome contro...

Страница 13: ...Within a building set different host IDs for multiple wireless congress systems to avoid mutual interference 2 Frequency sweep enter the Frequency sweep interface and select Yes to conduct frequency 5...

Страница 14: ...s terminal Function description host ID is a code used within a system for internal communication Communication can be successful only when the host ID of the system is consistent with that of a congr...

Страница 15: ...The system is recommended to use in the medium or small conference room 14 Product model WAP 30 3 2 1 Basic Functions 1 RUN indicator 2 Powered by the congress server 3 Wall mounting bracket supporti...

Страница 16: ...owered by the universal power supply and automatically matched by the voltage of the city power Each charging grid has a charging indicator light The charging circuit can automatically detect the batt...

Страница 17: ...nect the 8P interface female connector of the server to a WAP 30 AP with one male connector of the cable connected to the congress server and the other female connector connects the male connector of...

Страница 18: ...frequency band 2 4000 2 4835 GHz 4 3 2 Wireless PC Network The wireless PC network is based on 2 4GHz wireless communication technology as well and there are 13 channels available on the PC network R...

Страница 19: ...nt kinds of materials Minor impact glass wood gypsum asbesto Major impact water brick stone Completely block marble cement concrete metal The following instructions should be followed when you are ins...

Страница 20: ...ng apart from room A Situation 1 Room A B C on the same floor or neighboring floor because they are very near each other RF PARM Host ID and broadcast channel shall be DIFFERENT Room A RF PARM FIX 1 H...

Страница 21: ...Channel 1 Fix2 Fix3 or Fix 1 Channel 6 Fix3 or Fix1 Fix2 Channel 11 the HOST ID and broadcast channel of DCS3021 shall be different The other 2 4GHz wifi devices can reserve one channel to work in thi...

Страница 22: ...h 1 5m 5 1 2 8PS 03 05 10 15 20 40 Extension Cable Item Color Black Type 8PS Connector Male connector x 1 female connector x 1 Length 5 types namely 3m 5m 10m 15m 20m Description 5 1 3 UTP Five Catego...

Страница 23: ...dB signal to noise ratio based on A weight LINE OUT 20dBu AV110 220V 10 50 60Hz 19inch standard rack 1U rack 340mm 420mm 45mm 4KG 0 45 C 20 50 C RS 485 AUTO FIFO 1 2 3 1 PELCO P 9600 VISCA 1 RS 232 1...

Страница 24: ...gistration Operating temperature Storage temperature Sound pickup distance Built in loudspeaker Product Name Item 2 4GHz frequency hopping 30Hz 16KHz 7 5dB 46dB 1dB 3 7V 2600mAH lithium ion battery DC...

Страница 25: ...e Power Charging duration Weight Dimensions Operating temperature Storage temperature Product Name Item Charging case Parameter AC100 240V 50 60Hz 4 2V 106W 3 5h 6 7 kg net weight 7 4 kg fully loaded...

Страница 26: ...a risk of fire or other damage 6 Do not dismantle the housing of the congress terminals otherwise the product poses a risk of electric shock To maintain the devices contact GONSIN after sales service...

Страница 27: ...her the and of the RS 485 cable is reversely connected and whether the copper core of the binding post is inserted into the RS 484 interface of the central control unit and locked Check the ID and pro...

Страница 28: ...to product upgrade or change of product appearance and specification information in this document is subject to change without notice GONSIN reserves the right of final interpretation Before use pleas...

Страница 29: ...DCS 3021 Congress System 27...

Страница 30: ...GONSIN Conference Equipment Co Ltd...

Отзывы: