![GONSIN DCS-3021 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/gonsin/dcs-3021/dcs-3021_user-manual_2242092013.webp)
12
11
Use 8I+8O HD matrix with the SDIOUTPUT connected with an RGB connector. Connect the matrix to a display
device (such as monitor or converter) using an HD video cable. Refer to the following figure:
When connecting the congress server to a SONY EVI-D70/D70 camera, set the COM mode of the camera to RS-
422 and baud rate to 9600bps; connect RS-485 “A” to RXD IN- and “B” to RXD IN+.
Note: for details on how to set video tracking, refer to the software operation guide.
2.4.5 Connection with the Dome Controller
Make sure that the GX-KB01 dome controller’s protocol and baud rate are already preset (please see dome
controller user manual for the settings). Use a 2-pin twisted pair cable to connect 485+ and 485- of dome controller
to 485+ and 485- of central control unit. Please note that the RS485 control cable of dome camera is already
connected with RS485 control cable of central control unit.
The control cable of dome controller can also be connected to control cable of dome camera.
2.4.6 Congress Server Setting and Operation
The LCD screen has five keys:
▲, ▼, ▶, ◀,
and
“OK”. After entering the setting interface, the current
option is displayed on a contrast background. The
leftward and rightward arrow keys are used to enter
or exit a menu.
(1) Current status: when the system works normally,
the OLED shows the number of active microphones
and speaking mode, as shown in the following figure:
(
interface, press arrow keys to select the value after
Active MICs, and then press
▲
or
▼
to change the
number of MICs (1/2/3) that can be activated at the
same time.
2) Active MIC setting: Press OK to enter the setting
(
3) Speaking mode setting: on the setting
interface, press arrow keys to select the value
after Mode and press ▲ or ▼ to change a
speaking mode: AUTO or FIFO.
4
HostID: enter the "HostID" interface to set the host ID
of the system. The default host ID is 000
00000
.
(
4
) System setting: on the setting interface, press
arrow keys to select and enter the “System”
setting interface. The interface has the following
parameters for users to set:
Volume control lock
If volume control is locked, rotating the volume
knob will not work.
If volume control is unlocked, rotating the volume
knob will work.
Functional description: host ID is a code used within
a system for internal communication. Communication
can be successful only when the host ID of the
system is consistent with that of a congress terminal.
Within a building, set different host IDs for multiple
wireless congress systems to avoid mutual
interference.
2
Frequency sweep: enter the "Frequency sweep"
interface and select "Yes" to conduct frequency
5
Frequency point: enter the "
RF PARM
" interface. The
current RFs are shown. Select "SET" to rearrange the five
optimal frequencies; select
"FIX" to restore to default frequencies. Select "OK" to
return to preceding menu.
sweep. The system will scan and select five
optimal frequencies for the system to use. If you
select "No", the system goes back to the
preceding menu.
3
Unified
shutdown: Enter the "
Shutdown Unit
" interface
and select "Yes". The system will shut down all congress
terminals; if you select "No", the system goes back to the
preceding menu.
(Note:when using the microphone with
built.
in speaker, the
microphone will automatically correspond to
the host frequency after turn on the microphone power,
which means the microphone
can be used after scaning the
frequency.)
-
+
-
+
INTERPRETER
UNIT
AUDIO IN
-
+
-
+
+-+-
+-+-
GONSIN30000
DCS-3021 Congress System
1
Содержание DCS-3021
Страница 1: ...DCS 3021 Conference System User Manual...
Страница 3: ...02 DCS 3021 Congress System Chapter 8 FAQs Appendix 25 24...
Страница 29: ...DCS 3021 Congress System 27...
Страница 30: ...GONSIN Conference Equipment Co Ltd...