15

 

8.

 

Info  

Read the software and firmware version. 

 

 

9.

 

Refresh 

This function not only can refresh the information of setting but also can reconnect this device. You 

can click 

  button to update the control connection. A “ReConnectForm” window will pop 

up for you to select the approach to connect this device. 

   

 

Method C: Firmware Update through mini-USB Port 

1.  Please ensure the file of new firmware file is in the root directory of USB Flash Drive. The file name 

should be 

firmware.bin

2.  Use mini-USB to female USB type A cable to connect the USB interface of device and USB Flash 

Drive. 

3.  Switch dip switch on F/W mode. 
4.  Power cycle the device and it will automatically start the FW update process (The process will take 

about 10 seconds). 

 

 

16

 

Method D: Cloud Control (IntriCloud) through Ethernet Port 

Create Account 

The first time to use the IntriCloud service, please create a new account. 

 

1.  Access IntriCloud (

http://www.intri.cloud

) and click “Create new account”.

 

 

 

 

2.  The Registration page will pop up and please fill in your email and password information to 

create your private account. 

 

 

 

Содержание VW-1404ZH-G

Страница 1: ...ngs marked on this unit Do not attempt to service this unit yourself except where explained in this manual Provide proper ventilation and air circulation and do not use near water Keep objects that might damage the device and assure that the placement of this unit is on a stable surface Use only the power adapter and power cords and connection cables designed for this unit Do not use liquid or aer...

Страница 2: ...to 1920x1200 Supports remote control to switch 1x1 2x2 1x3 rotate and 1x4 rotate mode Supports independent input rotation at the resolution up to 1080p 4K2K60 YUV 4 4 4 can be divided and displayed onto four 1080p60 TV 2x2 layout only Supports individual propagation delay on each display to have the best visual perception PACKAGE CONTENTS 1x VW 1404ZH G 1x User Manual 1x 1U rack mounting ear set 1...

Страница 3: ...playPort the LED indicator will blink 2 IR SENSOR IR sensor for receiving the IR commands from IR remote 3 Control buttons Button 1 Source Source setting HDMI or DisplayPort Button 2 LOCK Press button for 3 seconds will enable disable device locked Button 3 2x2 Fast switch to 1x1 and 2x2 Button 4 90 Fast switch to 3x1 90 and 4x1 90 Button 5 90 Fast switch to 3x1 90 and 4x1 90 Button 6 Preset 1 But...

Страница 4: ...60Hz 1600x1200 60Hz 6 OPERATION APPROACH Method A IR Remote Control Button Function INFO Display device status IN OUT Resolution EDID Layout MUTE Turn off the stereo audio output POWER Power ON OFF the video wall processor Fast switch to VW1x1 Full Screen SOURCE Source setting HDMI or DisplayPort Fast switch to VW3x1 90 Fast switch to VW2x2 Fast switch to VW4x1 90 Fast switch to VW4x1 90 PRESET Pr...

Страница 5: ...Connection Enter the device IP address and click the OK button After the software control setting is accomplished it will enter directly to the control interface 1 2 3 4 6 8 9 5 7 8 Control Interface 1 Connection Status Show the connect information and status If you use USB control Mode to connect device the graph is For IP control the graph of Ethernet is 2 Quick Selection Quick Selection functio...

Страница 6: ...d 2 3 Note that when you want to change another mode you need to back to the step 2 to change Quick Selection From file Custom define 10 3 Step 2 1 quick selection If you choose the Quick Selection mode in step 2 this window will automatically pop up In this mode you can select default screen split and rotate screen rotate screen only at 1080p resolution 3x1 This mode will divide the screen into 3...

Страница 7: ... four directions After adjusting the image the rest of this image will be auto scaled to fulfill the screen Horizontal shift Vertical shift You can arbitrarily move the image on each screen in horizontal direction or vertical direction Move one pixel at a time 12 3 EDID Extended Display Identification Data 1 Learn EDID from the default Select Default EDID 1 5 default EDID Click button to learn def...

Страница 8: ...ut display will be forced to 2x2 layout other layout cannot set and only can set up the output position We also provides 8 preset spaces to save the frequently used scenarios into the device 6 Cloud setting Association Code Clicking button to get an association code The device can use this code to pair with cloud server After a successful pairing you can reset cloud Please pair device to cloud wit...

Страница 9: ...Drive The file name should be firmware bin 2 Use mini USB to female USB type A cable to connect the USB interface of device and USB Flash Drive 3 Switch dip switch on F W mode 4 Power cycle the device and it will automatically start the FW update process The process will take about 10 seconds 16 Method D Cloud Control IntriCloud through Ethernet Port Create Account The first time to use the IntriC...

Страница 10: ...loud http www intri cloud and then log in your account on the right top corner Click Add device to add the device which you just got its association code 3 Enter the Installer Email for online support in the future and the Association Code for pairing with your device 18 4 After adding the device the list of device related to your account will show on the right top corner You can click the button ...

Страница 11: ...c discharge and power surge This warranty is offered by the SELLER for its BUYER with direct transaction only This warranty is void if the warranty seal on the metal housing is broken Unit that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair Such repairs are warranted for 90 days from the day of reshipment to ...

Отзывы: