Access
panel
door
ON
1 2 3 4 5 6
SW1
NA2
+
AP-
C1 NA1
AP+
C2 AP+ AP- P1 P2 BUSBUS
_
AP1
NA2
+
AP-
C1 NA1
AP+
C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Connection of 2 DC lock releases without “AP”:
Important:
.
With 2 DC lock releases, it is not possible to use the
“
AP
”
door opening buttons
(1)
Mains
230Vac
SEC
~
~
~
~
PRI
TF-104
Lock release
ac 850
max. 12 V
/
mA
Connection of 1 AC lock release with “AP”:
NA2
+
AP-
C1 NA1
AP+
C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
(1)
To the FA-GB2/A
power supply
(1)
Lock release
max. 12 Vdc/270mA
Connection of 2 AC lock release with “AP”:
SEC
PRI
TF-104
Access
panel
door
ON
1 2 3 4 5 6
SW1
Access
panel
door
ON
1 2 3 4 5 6
SW1
WIRING DIAGRAMS:
18
Relay 2
Relay 1
12Vdc
Lock release
ac 850
max. 12 V
/
mA
~
~
~
~
AP1
AP2
Mains
230Vac
Connection of Golmar AC and DC lock releases.
ó
ó
To the FA-GB2/A
power supply
ó
To the FA-GB2/A
power supply
Important:
Fit the varistor supplied with the kit directly to the terminals of the lock release.
Important:
Fit the varistor supplied with the kit directly to the terminals of each of the 2 lock releases.
*
*
*
*
*