128
MONITORS PROGRAMMING
rogramming the Platea Plus / Tekna Plus monitors.
P
Set to ON the switch number 2 of the SW2 configuration dip switch, placed
at the upper left side (back) of the module EL631/Plus. The door panel
will reproduce a sound to advise that the system has entered into
programming mode.
In systems with more than one door panel, the programming process shall
be done on the master door panel only.
To program the monitor from a general door panel (if it exists), see page 119.
Switch off the monitor to be programmed.
Once the monitor is off, press the door release push button.
With the door release push button pressed switch on the
monitor.
To show that the system is ready for programming, the door
panel will reproduce a tone and the picture will appears
on the monitor. At this moment, the door release push
button can be released. Lift the handset to establish audio
communication with the door panel.
Press the door panel push button that will
call to this monitor. At this moment the
door panel will reproduce a tone and the
monitor led will blink.
To program the monitor as master, switch it
off and on again.
To program it as slave, press the door
release push button.
To program it as slave with intercom
function press the
push button.
Each apartment must have one master unit only; in case of parallel units configure them as slaves,
both monitors or telephones.
Make a call to check that the monitor has been succesfully programmed.
Repeat these steps to program the rest of monitors.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the door panel will reproduce a tone to advise that the
system is still into programming mode.