background image

8

7

ableado de los pulsadores.

C

DOOR P

ANEL INST

ALLA

TION

DOOR P

ANEL INST

ALLA

TION

Link the sound module with the EL500

     microprocessed circuit by using

     the supplied flat cable.

Select a direction to open the door panel; this selection should ease

     the door panel wiring

.

     The opening direction will be settled through the hinges position,

     that must be passed through the header clips as shown.

     F

or example, if the hinges are placed on both clips of the lower

     header

, the door panel will open downwards; if they are placed

     on the right clips of both headers, the door panel will open to left.

To

 hold the door panel on the embedding box,

     insert the hinges in the embedding box lockers

     as shown.

old the door panel on the embedding box.

H

For a quality finish, pass the push buttons wires through

     the spacer hole of the closest module.

2

     It's recommended to use wires of less than 0,25mm

     section.

IMPOR

TANT: link the push buttons common terminal

     of the several push buttons modules.

     The common terminal of the push buttons contained

     in a module are linked from factory

     This wire must be connected to the CP terminal

     of the EL500 microprocessed circuit or of the

     corresponding EL516 encoder circuit.

Twist the call wires as shown. The call wires will be

     connected to the EL500 microprocessed circuit or

     to the corresponding EL516 push buttons encoder

.

lace the nameplate labels.

P

Open the label holder

.

Place the label and

     close.

Содержание T500EN

Страница 1: ...Stadio Plus T500EN rev 0205 Instructions manual Audio and Video door entry system digital installation...

Страница 2: ...and a half minutes or until the handset is replaced Once the communication has finished the system will be freed O To open the door press the door release push button during call or communication prog...

Страница 3: ...the door panel should be placed at 1 65m height roughly The hole dimensions will depend on the number of door panel modules The door panel has been designed to be placed under most of the environmenta...

Страница 4: ...marked in the lower module and fix it by screwing the module shafts Place the module spacer between lower and next modules assuring that the spacer adjustment notches are inside the panel Fix the modu...

Страница 5: ...on the embedding box insert the hinges in the embedding box lockers as shown old the door panel on the embedding box H For a quality finish pass the push buttons wires through the spacer hole of the...

Страница 6: ...L516 circuits With 5 EL516 circuits With 6 EL516 circuits With 7 EL516 circuits With 8 EL516 circuits 8 7 15 22 6 15 15 36 5 15 15 15 50 4 15 15 15 15 64 3 15 15 15 15 15 78 2 15 15 15 15 15 15 92 1 1...

Страница 7: ...installations the EL562 module must be plugged in all the monitors and JP2 jumper of the EL500 circuit must be placed on the position specified on page 11 Refer to the specific installation diagram es...

Страница 8: ...ts in case of a FA Plus model Link power supplies to connect more units than the specified as it s shown on page 24 The power supply must be installed in a dry and protected place It s recommended to...

Страница 9: ...Floor Door Stair PLATEA Plus 0000000000 N serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachment...

Страница 10: ...onal device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L562 module for video installations E with twisted pair cable andling the end of line jumper H hang...

Страница 11: ...e In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release pu...

Страница 12: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description Tpositive ground audio di...

Страница 13: ...es both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished set t...

Страница 14: ...e first distributor INSTALLATION DIAGRAMS ideo installation with coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building I...

Страница 15: ...CTIONS CHART 50m Distance 150m A A A D in out V V V M in out p d p d CV CV INSTALLATION DIAGRAMS ideo installation without coaxial cable v The installation diagram shows the connection of a video syst...

Страница 16: ...tion A 1 00mm 2 50mm 0 25mm 0 25mm Terminal SECTIONS CHART 50m Distance 150m A A A D in out CV CV Place this power supply as closest as possible to the first telephone The installation diagram shows t...

Страница 17: ...SCART connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminal...

Страница 18: ...s with the exception of a shortcircuit between CTO and monitor or distributor terminals O Nothing operates w Check the output power supply voltage between and terminals it should have 17 5 to 18 5Vd c...

Страница 19: ...el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior notice golmar golma...

Отзывы: