background image

32

31

SA

+

TT

RR

MM

SAR-90

SA

+

TT

RR

MM

SAR-90

TF-104

SEC

~
~

CV+

CV

-

-

A

+

_

D

INT

A

_

+

DA

1

Malla

V

in

V

out

CN4

A

_

+

DA

1

Malla

V

in

V

out

CN4

A

_

+

D

INT

Malla

V

in

V

out

CN4

A

_

+

D

Malla

V

in

V

out

CN4

OPTIONAL CONNECTIONS

OPTIONAL CONNECTIONS

The lock release can be activated at any moment

     by using an external push button, that must be

     connected between 'CV

' y '

' terminals of the

     EL500 circuit. This function will allows to exit from

     the building being not necessary the use of a key

.

––

xternal lock release activation.

E

uxiliary devices activation.

A

To

 activate auxiliary devices the use of a SAR

-90 relay unit will be required. If this device is

     shared for all the monitors, link their A1 terminal and use just one relay unit.

     In case that each monitor has its own application use a SAR

-90 relay unit for each monitor

     and don't link the A1 monitor terminals.

To

 activate this function, press 

 monitor push button at any moment with no dependence of

     the handset position.

Usual applications are the activation of stairs light, second lock release, ...

The use of a TF

-104 transformer will be necessary to activate a second lock release.

IMPOR

TANT

: the lock release must be 12Vc.a. type.

To

 stairs light push button

onnecting the Shiner Plus monitor 

C

to a video recorder or TV

.

If your TV or video recorder have a SCAR

T

     connector

, it will be possible to view

     the picture from the door panel on the TV

     screen.

R

emove the end of line jumper

, that's placed on the

     CN4 connector

. Connect the coaxial cable

     between terminals 17 (shield) and 20 (hot)

     of the SCAR

T connector

.

ntercom function.

I

Platea Plus monitor and T

-940 Plus telephone have intercom facility between two units of the

     same apartment

. T

o

 enable this function check the following conditions:

          - One of the units has been configurated as master and the other unit as slave with

               intercom, as described on pages 20 and 23.

               In case to intercom one monitor with one telephone, configure the monitor as master

..

          - Link the INT terminal of the units, as it is shown on the enclosed diagram.

To

 establish an intercom communication lift the handset and press the intercom push button;

     acoustic tones will be reproduced on the handset confirming the call is in progress or

     that the other unit is communicating with the door panel. T

o

 establish communication lift

     the handset of the called unit

. If during an intercom communication a call is made from

     the door panel, acoustic tones will be heard on the master unit handset and the picture

     will appear in case of a monitor; press the intercom push button of the master unit 

     to establish communication with the door panel, or press the door release push button to

     activate the lock release.

The reproduced acoustic tones are different depending on their provenance, that allows the

     user to distinguish where the call is made from.

Содержание T500EN

Страница 1: ...Stadio Plus T500EN rev 0205 Instructions manual Audio and Video door entry system digital installation...

Страница 2: ...and a half minutes or until the handset is replaced Once the communication has finished the system will be freed O To open the door press the door release push button during call or communication prog...

Страница 3: ...the door panel should be placed at 1 65m height roughly The hole dimensions will depend on the number of door panel modules The door panel has been designed to be placed under most of the environmenta...

Страница 4: ...marked in the lower module and fix it by screwing the module shafts Place the module spacer between lower and next modules assuring that the spacer adjustment notches are inside the panel Fix the modu...

Страница 5: ...on the embedding box insert the hinges in the embedding box lockers as shown old the door panel on the embedding box H For a quality finish pass the push buttons wires through the spacer hole of the...

Страница 6: ...L516 circuits With 5 EL516 circuits With 6 EL516 circuits With 7 EL516 circuits With 8 EL516 circuits 8 7 15 22 6 15 15 36 5 15 15 15 50 4 15 15 15 15 64 3 15 15 15 15 15 78 2 15 15 15 15 15 15 92 1 1...

Страница 7: ...installations the EL562 module must be plugged in all the monitors and JP2 jumper of the EL500 circuit must be placed on the position specified on page 11 Refer to the specific installation diagram es...

Страница 8: ...ts in case of a FA Plus model Link power supplies to connect more units than the specified as it s shown on page 24 The power supply must be installed in a dry and protected place It s recommended to...

Страница 9: ...Floor Door Stair PLATEA Plus 0000000000 N serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachment...

Страница 10: ...onal device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L562 module for video installations E with twisted pair cable andling the end of line jumper H hang...

Страница 11: ...e In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release pu...

Страница 12: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description Tpositive ground audio di...

Страница 13: ...es both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished set t...

Страница 14: ...e first distributor INSTALLATION DIAGRAMS ideo installation with coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building I...

Страница 15: ...CTIONS CHART 50m Distance 150m A A A D in out V V V M in out p d p d CV CV INSTALLATION DIAGRAMS ideo installation without coaxial cable v The installation diagram shows the connection of a video syst...

Страница 16: ...tion A 1 00mm 2 50mm 0 25mm 0 25mm Terminal SECTIONS CHART 50m Distance 150m A A A D in out CV CV Place this power supply as closest as possible to the first telephone The installation diagram shows t...

Страница 17: ...SCART connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminal...

Страница 18: ...s with the exception of a shortcircuit between CTO and monitor or distributor terminals O Nothing operates w Check the output power supply voltage between and terminals it should have 17 5 to 18 5Vd c...

Страница 19: ...el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior notice golmar golma...

Отзывы: