20
19
Avoid to place the monitor near to heating sources,
in dusty locations or smoky environments.
To
install the monitor directly over the wall,
drill two holes of Ø6mm. and use the supplied screws.
The upper part of the monitor connector must be placed
at 1,60m. height roughly
. The minimum distance
between the monitor connector and the closest object
must be 5cm.
Place the monitor at right angles to the connector
and align the attaching holes of the monitor
with the attachment hooks of the connector
,
as it is shown on the drawing
.
Lock out the monitor
. P
ress the right side
till the attachment clip locks the monitor
firmly
.
To
disassemble the monitor from the connector
,
use a plain screwdriver to release the
attachment clip. R
emove the monitor from
the connector
, with special attention do not
falls.
MONIT
OR INST
ALLA
TION
MONIT
ORS PROGRAMMING
ix the monitor connector to the wall.
F
ix the monitor
.
F
Set to ON the switch number 2 of the configuration dip switch, that's
accessible by opening the terminal connector protection cover
.
The door panel will reproduce a sound to advise that the system
has entered into programming mode.
In systems with more than one door panel, the programming process
shall be done on the master door panel only
.
Switch off the monitor to be programmed.
Once the monitor is off
, press the door release push button.
W
ith the door release push button pressed
switch on the monitor
.
To
show that the system is ready for programming
,
the door panel will reproduce a sound and the picture
will appears on the monitor
. At this moment, the door
release push button can be released. Lift the handset
to establish audio communication with the door panel.
Press the door panel push button that will
call to this monitor
. At this moment
the door panel will reproduce a sound
and the monitor led will blink.
To
program the monitor as master
, switch it
off and on again.
To
program it as slave, press the door
release push button.
To
program it as slave with intercom
function press the
push button.
Each apartment must have one master unit only; in case of parallel units configure them
as slaves, both monitors or telephones.
Make a call to check that the monitor has been succesfully programmed.
R
epeat these steps to program the rest of monitors.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the door panel will reproduce a sound to advise
that the system is still into programming mode.
rogramming the monitors.
P