33
34
INDEX
SYSTEM OPERATION
O
O
O
O
O
O
O
O
O
w
w
w
w
w
w
w
Video door entry system with simplified installation (polarised 2 wire bus).
Up to 2 access door panel.
O
Up to 2 monitors per installation, (each monitor needs its own FA-22 power supply).
Acoustic call acknowledgment signals.
maximum distance between the door panel and the last montor: 80m.
Maximum distance between power supply and monitor: 10m.
Door opening timed at 2 seconds.
D.C. lock release.
Contact free auxiliary for activating auxiliary devices, do not switch voltage and current higher than
12Vcc/1A between C and NO door panel terminals.
Platea-22 monitor
:
"Autoswitch-on" function.
"Intercommunication" function.
Activation auxiliary device.
B/W and Colour monitor.
w
Three positions call reception volume control: maximum, medium and mute.
Brightness and contrast control (colour control in case of colour screen).
Different call tones which identify the call procedure: door panel and intercom.
Four different ring tones selection for door panel call.
O
To make a call, the visitor should press the over one of the push button ends, as it is shown on the label of
the push button. At this moment, the call will be received at the monitor(s) in the apartament.
O
The call tone lasts for 40 seconds, unknown to the visitor, the picture is displayed in the monitor (s) just a
few seconds after the call is received. If the call is not answered in 40 seconds, the picture will
disappears.
O
To establish communication pick up the monitor handset. The picture will disappears on the second
monitor (if exists).
O
The communication will last for 80 seconds or until the handset is replaced.
O
if during communication with a door panel, a call is made from a second door panel (if exists), the
monitor in communication will automatically enter in communication with the last calling door panel.
O
To open the door, press the door release push button during call reception, communication or
autoswitch-on processes: with one press, the door release operates during 2 seconds.
During activation, the picture will disappear from the monitor screen.
O
The description of the function push buttons is shown on page 41.
SYSTEM CHARACTERISTICS
Introduction ...........................................33
Índex.....................................................33
Starting recommendations .......................33
System characteristics ..............................34
System operation ....................................34
Door panel PVS-220 ...................................
Description..........................................35
Location......................................36 to 37
Wiring.................................................37
Final adjustements................................37
Push button label ..................................38
Close the door panel.............................38
Power supply ..............................................
Installation ..........................................39
Characteristics .....................................39
Lock release installation ...........................39
Platea 22 monitor .......................................
Description..........................................40
Function push buttons ...........................41
Call volume control ..............................41
Configuration switches..........................41
Monitor connector description ...............42
Monitor installation...............................43
Changing the front film..........................44
Ring tone selection................................44
Intercom function .................................44
Installation diagram ....................................
One or two door panels.........................45
Connection of an additional monitor.......45
Sections chart ......................................46
Connection a.c. lock release..................46
Connection auxiliary device ...................46
Troubleshooting hints ..............................47
STARTING RECOMMENDATIONS
O
O
O
O
O
O
O
O
O
O
O
Do not use excessive force when tightening the power supply connection block screws.
Install the equipment without the power connected.
Before connecting the system, check the connections between door panel, monitors and the
power supply connection.
Only use compatible color and b&w monitor Platea-22.
Only use parallel or twisted cable (to sections see page 46).
Do not use single wire
Do not double the cable to increase the section.
O
The entire installation must be at least 40 cm. away from any other installation otherwise there is
a risk that the audio signal be exposed to interference, or that the system does not work correctly.
Always use 12 Vd.c. lock releases (cod. 20600149, not included i the kit).
Do not switch voltage higher tha 12 Vd.c. / 1A between C and NO door panel terminals.
Both monitor and door panel are delivered with a protective film, to avoid scratches during the
installation. These films must removed by the end user only.
Do always follow the enclosed information.
.
INTRODUCTION
First of all we would like to thank and congratulate you for the purchase of this product
manufactured by Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification
and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the
legion of features this system offers. To obtain the maximum profit of these features and a properly wired
installation, we kindly recommend you to expend a few minutes of your time to read this manual.