SYSTEM OPERATION

The telephone interface makes the functions of a 4+N audio door entry system compatible with a
fixed-line telephone, being possible to divert calls to the fixed-line or mobile networks.

The interface allows three types of communication:

When a call is made from the audio door entry system it will be received on the apartment's fixed-

line telephone. Audio communication with the door entry system will be established upon picking
handset up.

During communication it is possible to send the following commands using the telephone's

keypad:

“5” Door opening.
“0” Triggers the auxiliary relay used for activating auxiliary devices (bells, lights, ...).

The volume levels of the microphone and speaker can be adjusted during communication with

the audio door entry system using the telephone's keypad:

“1” Increases the audio door panel's speaker volume.
“7” Lowers the audio door panel's speaker volume.
“4” Confirms and memorises the changed volumes for the audio door panel's speaker.
“3” Increases the telephone's speaker volume.
“9” Lowers the telephone's speaker volume.
“6” Confirms and memorises the changed volumes for the telephone's speaker.

When a call is received from the telephone line during communication with the audio door entry

system, a tone from the telephone's speaker will be heard. Audio communication can be switched
between the door entry system and the telephone line call using the telephone's keypad:

“2” Switch communication to the audio door entry system.
“8” Switch communication to the telephone line call.

Depending upon its programming, the interface can differentiate between calls from the audio door
entry system and from the telephone line, selecting between 3 types of cadence.

To end communication, replace the telephone handset.

When a call is received from the audio door entry system while a telephone line call is taking

place, a tone from the telephone's speaker advising of the incoming call will be heard. The user
can switch between both calls using the telephone's keypad:

“2” Switch communication to the audio door entry system.
“8” Switch communication to the telephone line call.

During communication with the door entry system, it is possible to execute the commands

described in the “Communication with the audio door entry system” point.

To end communication, replace the telephone handset.

Communication with the audio door entry system:









Communication with the telephone line, incoming call:

43

Содержание IT-4N

Страница 1: ...IT 4N TELEPHONE INTERFACE INTERFAZ TELEFONICO 12V 50Hz 700mA input P1 10 5 3 0 M 7 PD DA RA RB LA LB PA PB IT 4N Telephone Interface Instructions manual TIT 4N ML rev 0108...

Страница 2: ...6 Connecting an audio door entry system to an IT 4N telephone interface 56 Connecting an audio door entry system to an IT 4N telephone interface with a cellular PABX 57 Troubleshooting hints 58 Compli...

Страница 3: ...ntry system or from the telephone line Allows switching between calls from the subscriber loop and the audio door entry system using the telephone s keypad keeping both connections active Compatible w...

Страница 4: ...s for the telephone s speaker When a call is received from the telephone line during communication with the audio door entry system a tone from the telephone s speaker will be heard Audio communicatio...

Страница 5: ...eaker 3 Increases the telephone s speaker volume 9 Lowers the telephone s speaker volume 6 Confirms and memorises the changed volumes for the telephone s speaker When a call is received from the telep...

Страница 6: ...a fixed line the interface can be connected under the following configurations The apartment s telephone is connected to the interface s local subscriber loop where it performs the functions of teleph...

Страница 7: ...not available after the interface As shown in the following examples the telephone interface can also be connected to a PABX s input line or to its extensions as long as these are analogue lines The...

Страница 8: ...local subscriber loop given that in this mode of operation the audio door entry system will always be connected to the PABX and call diverting will always be enabled In this mode of operation when a c...

Страница 9: ...re To install the interface directly on the wall drill two holes of 6mm and insert the wallplugs Fix the interface with the specified screws DIN 46277 Description of the interface DIN rail latch relea...

Страница 10: ...ld code Two medium duration tones Correct code value Four medium duration tones Error One long duration tone To ensure a correct programming of the system calls should not be made from either the audi...

Страница 11: ...l be done by fields See the table on page 51 To verify the state of programming and if the sequence is correct or not the handset s speaker will emit the following tones Programming mode accessed Five...

Страница 12: ...ype 71 0 Normal Operation 1 PABX non transparent Divert telephone 2 Divert telephone 3 Divert mode 17 Description of the programming fields PIN entry PIN change Divert telephone To access the programm...

Страница 13: ...e in the auxiliary relay type configuration field Establishes the time that the relay remains active this time can be configured between 01 and 60 seconds Number of divert Priority call Divert mode Lo...

Страница 14: ...vity for moderately noisy environments factory default 3 Low sensitivity for very noisy environments Ring type Reset local telephone volume Reset volume of diverted telephone Serves to differentiate b...

Страница 15: ...n t transmit the pick up or hang up signals the has the following configuration options 0 Normal operation the PABX is transparent 1 Operation with PABX the PABX is not fully transparent With this opt...

Страница 16: ...ect access code number using the telephone s keypad Function Code Enable call divert CD PLUS 4N Converter programming 1 Disable call divert Activate auxiliary relay Deactivate auxiliary realy Lock rel...

Страница 17: ...Distance 300m 3 1 2 CV SEC PRI TF 104 Main CV CP L1 L2 ind 1 ind 1 ind 3 ind 2 ind 3 P CN1 1 2 TF 104 Stadio Plus SEC PRI 0 10 5 3 P1 0 10 5 3 P1 Main EL555 1 2 3 ind 2 0 10 5 3 P1 Output to telephone...

Страница 18: ...EL555 1 2 3 ind 2 0 10 5 3 P1 8 9 7 4 5 6 3 2 1 0 Output to telephones Local subscriber loop 220Vac Power PABX aerial Telephone line Subscriber loop 12 VDC Tel Cellular PABX For greater distances ple...

Страница 19: ...the audio door entry system and the interface are correct Check the apartment s telephone connections to the interface s PAand PB terminals Check that the apartment s telephone is of the tone dial ty...

Отзывы: