golmar IT-4N Скачать руководство пользователя страница 12

PROGRAMMING

51

Programming fields:

Adjustable system parameters.

Field

Code

Field value

PIN entry

“##0”

The PIN has three digits.

PIN change

“00”

New PIN <3 digits>, repeat the PIN <3 digits>

Divert telephone 1

“10”

Enter the telephone number, 16 digits maximum.

“11”

Enter the telephone number, 16 digits maximum.
Enter the telephone number, 16 digits maximum.

“12”
“15”

“0”: Disabled; “1”: Enabled.

Number of divert

“16”

“1”: Divert to one ph.; “2”: Divert to two ph.; “3”: Divert to three ph.

Call (divert mode)

Calling order: “1”; “2”; “3”.

Lock release time

“20”

Between “01” and “60” seconds.

Auxiliary relay: Type

“30”

“0”: Normally open; “1”: Normally closed.

Auxiliary relay: Monostable time

“31”

Between “01” and “60” seconds.

Auxiliary relay: State

“32”

“0”: Monostable; “1”: Bistable.

Ring type

“40”

“1”: Cadence type; “2”: Cadence type; “3”: Cadence type.

Reset local telephone volume

“51”

Volume to default value, local telephone

Reset volume of divert telephone

“52”

Default volume, divert telephone “1”; “2”; “3” according to ph.

Door entry system sensitivity

“60”

“1”: High; “2”: Medium; “3”: Low.

System compatibilities

“70”

“0”: 4+N or 4+N Busy channel; “1”:Plus System

Divert type

“71”

“0”: Normal Operation; “1”: PABX, non-transparent.

Divert telephone 2
Divert telephone 3
Divert mode

“17”

Description of the programming fields:

PIN entry:

PIN change:

Divert telephone:



To access the programming menu enter “##0” followed by the PIN “123”.
This PIN has three digits.
This field stores the corresponding PIN.

The user can change the PIN in this field by accessing the programming mode and entering

the new PIN two times. If the new PIN is not repeated correctly the process will have to be
done again.

Each field stores a phone number which the audio door panel will call when the system has the

divert mode enabled.

Up to 16 digits from the sequence “0,1,2,3,4,5,6,7,8,9,#, ”can be used
The “#” character creates a pause in the dialling (when calls are made via a PABX,

certain models may require this).

The “ ” character indicates the end of the programmed telephone number.
If the call is not answered, the next programmed telephone number is called,

and so on until a maximum of three numbers is reached.

Calls can be diverted to telephones on fixed-line or cellular networks, or to extensions on private

telephone networks, with this last option requiring the PABX to be installed in the same system as
the telephone interface

*

*

.

Pick up detection

“72”

“0”: Automatic; “1”: Manual.

Содержание IT-4N

Страница 1: ...IT 4N TELEPHONE INTERFACE INTERFAZ TELEFONICO 12V 50Hz 700mA input P1 10 5 3 0 M 7 PD DA RA RB LA LB PA PB IT 4N Telephone Interface Instructions manual TIT 4N ML rev 0108...

Страница 2: ...6 Connecting an audio door entry system to an IT 4N telephone interface 56 Connecting an audio door entry system to an IT 4N telephone interface with a cellular PABX 57 Troubleshooting hints 58 Compli...

Страница 3: ...ntry system or from the telephone line Allows switching between calls from the subscriber loop and the audio door entry system using the telephone s keypad keeping both connections active Compatible w...

Страница 4: ...s for the telephone s speaker When a call is received from the telephone line during communication with the audio door entry system a tone from the telephone s speaker will be heard Audio communicatio...

Страница 5: ...eaker 3 Increases the telephone s speaker volume 9 Lowers the telephone s speaker volume 6 Confirms and memorises the changed volumes for the telephone s speaker When a call is received from the telep...

Страница 6: ...a fixed line the interface can be connected under the following configurations The apartment s telephone is connected to the interface s local subscriber loop where it performs the functions of teleph...

Страница 7: ...not available after the interface As shown in the following examples the telephone interface can also be connected to a PABX s input line or to its extensions as long as these are analogue lines The...

Страница 8: ...local subscriber loop given that in this mode of operation the audio door entry system will always be connected to the PABX and call diverting will always be enabled In this mode of operation when a c...

Страница 9: ...re To install the interface directly on the wall drill two holes of 6mm and insert the wallplugs Fix the interface with the specified screws DIN 46277 Description of the interface DIN rail latch relea...

Страница 10: ...ld code Two medium duration tones Correct code value Four medium duration tones Error One long duration tone To ensure a correct programming of the system calls should not be made from either the audi...

Страница 11: ...l be done by fields See the table on page 51 To verify the state of programming and if the sequence is correct or not the handset s speaker will emit the following tones Programming mode accessed Five...

Страница 12: ...ype 71 0 Normal Operation 1 PABX non transparent Divert telephone 2 Divert telephone 3 Divert mode 17 Description of the programming fields PIN entry PIN change Divert telephone To access the programm...

Страница 13: ...e in the auxiliary relay type configuration field Establishes the time that the relay remains active this time can be configured between 01 and 60 seconds Number of divert Priority call Divert mode Lo...

Страница 14: ...vity for moderately noisy environments factory default 3 Low sensitivity for very noisy environments Ring type Reset local telephone volume Reset volume of diverted telephone Serves to differentiate b...

Страница 15: ...n t transmit the pick up or hang up signals the has the following configuration options 0 Normal operation the PABX is transparent 1 Operation with PABX the PABX is not fully transparent With this opt...

Страница 16: ...ect access code number using the telephone s keypad Function Code Enable call divert CD PLUS 4N Converter programming 1 Disable call divert Activate auxiliary relay Deactivate auxiliary realy Lock rel...

Страница 17: ...Distance 300m 3 1 2 CV SEC PRI TF 104 Main CV CP L1 L2 ind 1 ind 1 ind 3 ind 2 ind 3 P CN1 1 2 TF 104 Stadio Plus SEC PRI 0 10 5 3 P1 0 10 5 3 P1 Main EL555 1 2 3 ind 2 0 10 5 3 P1 Output to telephone...

Страница 18: ...EL555 1 2 3 ind 2 0 10 5 3 P1 8 9 7 4 5 6 3 2 1 0 Output to telephones Local subscriber loop 220Vac Power PABX aerial Telephone line Subscriber loop 12 VDC Tel Cellular PABX For greater distances ple...

Страница 19: ...the audio door entry system and the interface are correct Check the apartment s telephone connections to the interface s PAand PB terminals Check that the apartment s telephone is of the tone dial ty...

Отзывы: