golmar IT-4N Скачать руководство пользователя страница 3

42

INTRODUCTION

Telephone interface for conventional 4+N systems (for both electronic calls and buzzers).

It permits the connection of a 4+N audio door entry system to the subscriber loop of the
corresponding apartment, allowing a conventional fixed-line telephone to take on the functionality
of a 4+N handset. This allows the following combinations:

Communication from the audio door entry system to the apartment's telephone.
Communication from the audio door entry system to the apartment's telephone with an ADSL

line.

Connection from the audio door entry system to telephone extensions in analogue PABXs.

It allows calls from the audio door entry system to be received on standard tone dial telephones
that work on fixed-line network “PSTN”. For this, they must be installed on the local subscriber
loop of the IT-4N telephone interface. A maximum of 4 telephones can be installed.

Divert function for calls originating from the audio door entry system to any telephone on the fixed-
line or cellular networks. A maximum of 3 telephone numbers can be programmed.

An acoustic indicator in the handset of the local subscriber loop informs of any calls from the audio
door entry system or from the telephone line.

Allows switching between calls from the subscriber loop and the audio door entry system using
the telephone's keypad, keeping both connections active.

Compatible with analogue PABXs, allowing the interface to be connected to the PABX's input line
or to its extensions.

Compatible with ADSL lines and with the splitters supplied by the ISP.

Allows the activation of functions and commands via the keypad of the telephone on the local
subscriber loop.

It has an input for enabling the call divert mode via an external switch.

It has a 12 Vcc/40mA output to indicate that the call divert mode is enabled.

It has a potential-free auxiliary output, NO/NC 30 Vdc/Vac 1A.

Operation LEDs that indicate the current state and mode of the interface.


First of all we would like to thank and congratulate you for the purchase of this product manufactured
by Golmar.

The commitment to reach the satisfaction of our customers is stated through the ISO-9001

certification and for the manufacturing of products like this one.

Its advanced technology and exacting quality control will do that customers and users enjoy with the
legion of features this system offers. To obtain the maximum profit of these features and a properly
wired installation, we kindly recommend you to expend a few minutes of your time to read this
manual.

SYSTEM CHARACTERISTICS

Содержание IT-4N

Страница 1: ...IT 4N TELEPHONE INTERFACE INTERFAZ TELEFONICO 12V 50Hz 700mA input P1 10 5 3 0 M 7 PD DA RA RB LA LB PA PB IT 4N Telephone Interface Instructions manual TIT 4N ML rev 0108...

Страница 2: ...6 Connecting an audio door entry system to an IT 4N telephone interface 56 Connecting an audio door entry system to an IT 4N telephone interface with a cellular PABX 57 Troubleshooting hints 58 Compli...

Страница 3: ...ntry system or from the telephone line Allows switching between calls from the subscriber loop and the audio door entry system using the telephone s keypad keeping both connections active Compatible w...

Страница 4: ...s for the telephone s speaker When a call is received from the telephone line during communication with the audio door entry system a tone from the telephone s speaker will be heard Audio communicatio...

Страница 5: ...eaker 3 Increases the telephone s speaker volume 9 Lowers the telephone s speaker volume 6 Confirms and memorises the changed volumes for the telephone s speaker When a call is received from the telep...

Страница 6: ...a fixed line the interface can be connected under the following configurations The apartment s telephone is connected to the interface s local subscriber loop where it performs the functions of teleph...

Страница 7: ...not available after the interface As shown in the following examples the telephone interface can also be connected to a PABX s input line or to its extensions as long as these are analogue lines The...

Страница 8: ...local subscriber loop given that in this mode of operation the audio door entry system will always be connected to the PABX and call diverting will always be enabled In this mode of operation when a c...

Страница 9: ...re To install the interface directly on the wall drill two holes of 6mm and insert the wallplugs Fix the interface with the specified screws DIN 46277 Description of the interface DIN rail latch relea...

Страница 10: ...ld code Two medium duration tones Correct code value Four medium duration tones Error One long duration tone To ensure a correct programming of the system calls should not be made from either the audi...

Страница 11: ...l be done by fields See the table on page 51 To verify the state of programming and if the sequence is correct or not the handset s speaker will emit the following tones Programming mode accessed Five...

Страница 12: ...ype 71 0 Normal Operation 1 PABX non transparent Divert telephone 2 Divert telephone 3 Divert mode 17 Description of the programming fields PIN entry PIN change Divert telephone To access the programm...

Страница 13: ...e in the auxiliary relay type configuration field Establishes the time that the relay remains active this time can be configured between 01 and 60 seconds Number of divert Priority call Divert mode Lo...

Страница 14: ...vity for moderately noisy environments factory default 3 Low sensitivity for very noisy environments Ring type Reset local telephone volume Reset volume of diverted telephone Serves to differentiate b...

Страница 15: ...n t transmit the pick up or hang up signals the has the following configuration options 0 Normal operation the PABX is transparent 1 Operation with PABX the PABX is not fully transparent With this opt...

Страница 16: ...ect access code number using the telephone s keypad Function Code Enable call divert CD PLUS 4N Converter programming 1 Disable call divert Activate auxiliary relay Deactivate auxiliary realy Lock rel...

Страница 17: ...Distance 300m 3 1 2 CV SEC PRI TF 104 Main CV CP L1 L2 ind 1 ind 1 ind 3 ind 2 ind 3 P CN1 1 2 TF 104 Stadio Plus SEC PRI 0 10 5 3 P1 0 10 5 3 P1 Main EL555 1 2 3 ind 2 0 10 5 3 P1 Output to telephone...

Страница 18: ...EL555 1 2 3 ind 2 0 10 5 3 P1 8 9 7 4 5 6 3 2 1 0 Output to telephones Local subscriber loop 220Vac Power PABX aerial Telephone line Subscriber loop 12 VDC Tel Cellular PABX For greater distances ple...

Страница 19: ...the audio door entry system and the interface are correct Check the apartment s telephone connections to the interface s PAand PB terminals Check that the apartment s telephone is of the tone dial ty...

Отзывы: