escription of the configuration jumpers and
D
memory banks.
JP1 and JP2 configuration jumpers are placed
on the left side of the bottom porter's exchange part,
closest to the hook switch.
JP3 jumper is placed in the middle of the pcb,
under the BK0 memory bank.
Jumper JP1 selects the call reception volume.
If after starting the system it's considered that
the volume is too high, modify the jumper position.
Factory default: maximum.
Jumper JP2 loads the installation with a communications
resistor. For a proper system operation, activate this resistor
only when installations without door panels.
Factory default: enabled.
Jumper JP3 allows to reset the installer PIN code to the factory
default (see page 10).
Use this function only in case to forget this code.
With the system switched on, change the jumper position
to reset the code and return it to the stand by position.
The porter's exchange has two memory banks
to plug 256Kb memory modules in.
Each module allows to record the custom
text for a maximum of 1000 users.
The system is delivered with one memory module
placed in the bank number 0 (BK0), where
the system configuration will be recorded.
In case of porter's exchanges with two memory modules,
don't change their position once they have been recorded
.
BK0 bank module must always have a memory module plugged in
.
Maximum.
Minimum.
Enabled.
Disabled.
Reset.
Standby.
PORTER'S EXCHANGE PROGRAMMING
10
rogramming menu.
P
golmar
16:30
Continue
1
5
ó
3
1
1
1
1
1
*
O.K.
ANCEL
C
9
BK0
JP3
BK1
PORTER'S EXCHANGE ADJUSTMENTS
The porter's exhange is adjusted from factory
with the most common parameters.
To change any of these parameters use a plain
screwdriver to open the porter's exchange,
as it is shown on the drawing.
pen the porter's exchange.
O
It will be necessary to enter into the programming menu to configure the system properties.
For a proper system operation, the menus marked with an
asterisk
must be configurated.
Two different programming menues are available:
installer
, that allows to modifiy any of the
system properties and
user
, that only allows changes that do not affect the system operation.
Programming options with black text and white background are availables in both menues;
options with white text and black background are only availables on installer menu.
The first time you enter into the programming menu, the display messages will appear in spanish.
Press OK when the display shows the message
configuracion
: the display will show now
castellano
. Press OK to change to english or till the desired language appears.
If the option Direct Call Code (page 12) is disabled, it will not be necessary to fill the repertory
name for a proper system operation.
Use the arrow keys to move through the programming menu. Option changes will be validate
by pressing OK key, even if CANCEL key is pressed later.
Use CANCEL key to exit from the configuration menu. The porter's exchange will automatically exit
from the configuration menu after 2 minutes with no operation.
This menu allows to fill the repertory and
to change its options.
Press OK to enter into this menu.
On this menu the system configuration options
can be changed.
Press OK to enter into this menu.
To enter into the main programming menu,
press key symbol and enter
the installer PIN code (factory default: 1315)
or the user PIN code (factory default: 1111).
repertory
pin code
pin:____
configuration