udio door entry system with a.c. lock release and
A
additional
TF-104
transformer.
The installation diagram shows the wiring of an audio door entry system with one or several door
panels to enter into the building.
If the system has one door panel only, do not take into account the connection towards others.
If the system has more than one door panel, wire the second panel as shown on the diagram.
In case of more than two door panels, wire them as the second panel.
REMEMBER:
The maximum number of door panel in parallel without using converters is three.
.
.
.
Maximum distance between the remote door pannel and furthest telephone: 100m.
Sections chart
1,00mm²
1,50mm²
1,50mm²
Terminal
SECTIONS CHART
100m.
50m.
50m.
Panel - Telephone
Panel
-
Panel
F.A. -
Panel
- CV
+, -, CV1, CV2,
~1
,
~2
For higher distances, consult our Technical Assistance Service.
BUS
INSTALLATION DIAGRAMS