Main door panel
76
udio door entry system with a.c. lock release and
A
EL502
dc/ac converter.
Main
BUS
L1
CV1 +12
CV2
L2
CN1
CV+
CV-
CN2 CN3
EL502
FA-PLUS/C
ver. 938072
SEC
PRI
+
230110 0
- - +
- +
The installation diagram shows the wiring of an audio door entry system with one or several door
panels to enter into the building.
If the system has one door panel only, do not take into account the connection towards others.
If the system has more than one door panel, wire the second panel as shown on the diagram.
In case of more than two door panels, wire them as the second panel.
REMEMBER:
The maximum number of door panel in parallel without using converters is three.
.
.
.
Maximum distance between the remote door pannel and furthest telephone: 100m.
Sections chart
1,00mm²
1,50mm²
1,50mm²
Terminal
SECTIONS CHART
100m.
50m.
50m.
Panel - Telephone
Panel
-
Panel
F.A. -
Panel
- CV
+, -, CV1, CV2,
~1
,
~2
For higher distances, consult our Technical Assistance Service.
BUS
INSTALLATION DIAGRAMS
75
Main
BUS
L1
CV1 +12
CV2
L2
CN1
CV+
CV-
CN2 CN3
EL502
FA-PLUS/C
ver. 938072
SEC
PRI
+
230110 0
- - +
- +
Slave door panel
Next floor
BUS
BUS
HZ
HZ
HZ
HZ
T-7720
T-7720
BUS HZ HZ
T-7720
BUS HZ
S+
HZ
S-
T-7722VD
PA PB
BUS HZ
S+
HZ
S-
T-7822VD
PA PB BUS F.Ligne
( )
*
( )
*
IMPORTANT:
Do not insert the resistor with a 2Plus system.
BUS HZ
S+
HZ
S-
T-7722VD
PA PB
JP3