Inlet
connection
region
for
flexible
hose
After
connecting
to
gas
,
check
for
leaks
using
soapy
solution
,
never
a
naked
flame
.
Fit
the
duplicate
data
plate
(
supplied
in
separate
bag
)
on
a
surface
adjacent
to
the
hotplate
,
for
example
,
the
inside
of
the
cupboard
door
so
it
is
clearly
visible
for
any
service
technician
.
SETTING
THE
GAS
PRESSURE
:
Fit
a
manometer
with
a
6
mm
rubber
hose
to
the
test
point
on
the
regulator
(
for
natural
gas
).
For
all
the
models
,
light
all
burners
on
and
adjust
test
point
pressure
to
1
.
00
kPa
.
Turn
burners
off
and
on
again
and
recheck
the
pressure
is
same
as
set
previously
or
adjust
as
required
.
TEST
FOR
CORRECT
OPERATION
:
After
installation
and
test
point
setting
,
each
burner
ignition
and
operation
must
be
tested
individually
and
with
all
burners
operating
.
This
testing
must
be
done
by
the
installer
before
leaving
.
ADJUSTING
THE
BURNER
MINIMUM
FLAME
HEIGHT
:
NOTE
:
This
adjustment
can
only
be
performed
by
authorised
service
personnel
.
The
minimum
burner
flame
is
factory
adjusted
for
the
gas
type
stated
on
the
gas
type
label
adjacent
to
the
gas
connection
and
should
not
require
adjustment
.
Adjustment
may
be
required
if
the
hotplate
has
been
converted
from
Natural
gas
to
Universal
LPG
or
vice
versa
.
GAS
CONVERSION
INSTRUCTIONS
:
The
manufacturers
servicing
instructions
detail
how
authorised
personnel
may
convert
the
hotplate
from
Natural
gas
to
Universal
LPG
or
from
Universal
LPG
to
Natural
gas
.
Contact
the
manufacturer
or
agent
as
required
.
Wiring
diagram
for
5
.
Gas
connection
Install
in
accordance
with
relevant
gas
standards
and
/
or
codes
of
practice
applicable
.
Connect
the
elbow
fitting
to
the
appliance
gas
manifold
connection
,
and
check
that
seals
between
the
elbow
and
manifold
connection
are
in
place
and
in
good
condition
.
For Natural gas : connect the natural gas appliance regulator (pictured opposite) with integral
test
point
using
approved
gas
thread
tape
or
compound
to
the
elbow
fitting
.
For Universal LPG : connect the Test point adapter (pictured opposite) with integral test point
using
approved
gas
thread
tape
or
compound
to
the
elbow
fitting
.
Ensure
the
supply
connection
point
,
test
point
and
natural
gas
regulator
adjustment
screw
(
for
Natural
gas
installation
)
are
accessible
for
testing
and
/
or
adjustment
with
the
hotplate
in
the
installed
position
.
Where
a
flexible
hose
assembly
is
used
,
ensure
it
is
approved
to
AS
/
NZS
1869
,
Class
B
or
D
with
max
.
length
of
1
.
2m
.
Any
hose
assembly
used
must
be
restrained
from
accidental
contact
with
the
flue
outlet
of
an
under
bench
oven
.
This
hose
assembly
shall
be
suitable
for
connection
to
a
fixed
consumer
piping
outlet
located
as
follows
:
Hotplates
at
a
point
800
mm
to
850
mm
above
the
floor
and
in
the
region
outside
the
width
of
the
appliance
to
a
distance
of
250
mm
.
Natural
gas
regulator
Issue Date :- 23/05/2017
Issue Date :- 23/05/2017