26

System Maintenance

To maintain maximum performance, it is recommended that you open and visually inspect the cell every 3

months or after cleaning your filter.  The Aqua Logic will remind you to do this by displaying the message

“Inspect/Clean Cell” after approximately 500 hours of operation.

The Aqua Logic electrolytic cell has a self cleaning feature incorporated into the electronic control’s logic.

In most cases this self cleaning action will keep the cell working at optimum efficiency.  In areas where

water is hard (high mineral content) or in pools where the water chemistry has been allowed to get “out of

balance”, the cell may require periodic cleaning.

Servicing and Cleaning the Aqua Logic cell

Turn off power to the Aqua Logic before removing the electrolytic cell.  Once removed, look inside the cell

and inspect for scale formation (light colored crusty or flaky deposits) on the plates and for any debris

which has passed through the filter and caught on the plates.  If no deposits are visible, reinstall.  If deposits

are seen, use a high pressure garden hose and try to flush the scale off.  If this is not successful, use a plastic

or wood tool (do not use metal as this will scratch the coating off the plates) and scrape deposits off of

plates.  Note that a buildup on the cell indicates that there is an unusually high calcium level in the pool (old

pool water is usually the cause).  If this is not corrected, you may to have to periodically clean the cell.  The

simplest way to avoid this is to bring the pool chemistry to the recommended levels as specified.

Mild Acid Washing:

  Use only in severe cases where flushing and scraping will not remove the majority

of deposits.  To acid wash, turn off power to Aqua Logic.  Remove cell from piping.  In a clean plastic

container, mix a 2:1 solution of water to muriatic acid (one gallon of water to two quarts of muriatic acid).

ALWAYS ADD ACID TO WATER - NEVER ADD WATER TO ACID.  Be sure to wear rubber gloves

and appropriate eye protection.  The level of the solution in the container should just reach the top of the

cell so that the wire harness compartment is NOT submerged.  It may be helpful to coil the wiring before

immersing the cell.  The cell should soak for a few minutes and then rinse with a high pressure garden hose.

If any deposits are still visible, repeat soaking and rinsing.  Replace cell and inspect again periodically.

Winterizing

The Aqua Logic electrolytic cell and flow detection switch will be damaged by freezing water just as your

pool plumbing would.  In areas of the country which experience severe or extended periods of freezing

temperatures, be sure to drain all water from the pump, filter, and supply and return lines before any

freezing conditions occur.  The electronic control is capable of withstanding any winter weather and should

not be removed.

If you are in an area that only experiences occasional freezing conditions, your Aqua Logic system may be

set up to circulate the pool water whenever the air sensor drops to 38ºF.  Make sure the air sensor is

recording the correct temperature and is NOT located in the direct sunlight to ensure proper freeze pro-

tection operation.

Spring Start-up

When first starting the pool in the spring time, it is highly recommended that you temporarily set the pool

and spa chlorinator settings (Settings Menu/Pool Sanitizer & Spa Sanitizer) to 0% (off) and then manually

shock the pool with any chlorine based shock product and balance the pool water chemistry per the levels

indicated in the Chlorinator Operation section (page 16).  Make sure to check the salt and stabilizer levels

and bring them up to the recommended levels.  Your local Authorized Aqua Dealer or pool store can

recommend the best chemical treatment for your pool.  After the water is clear and balanced, then go back

and adjust the pool and spa chlorinator settings to the appropriate levels.  Test the pool chlorine level

weekly and adjust the chlorinator settings up or down accordingly.

It is usually a good idea to also inspect the cell and clean if necessary at the start of the season.  See

instructions above.

Содержание Aqua Logic AQ-LOGIC-P-4

Страница 1: ...888 921 7665 actuators remote display not included on some models order separately Aqua Logic Aqua Logic Aqua Logic Aqua Logic Aqua Logic Automation and Chlorination Operation Manual for models AQ LOG...

Страница 2: ...nal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the equipment One bondin...

Страница 3: ...y 19 Set the Heater Temperature 19 Set the Chlorinator Output 19 Start Stop Superchlorination 20 Program a Timeclock 20 Program a CountdownTimer 20 Enter Exit Service Mode 21 Chlorinator Operation Sat...

Страница 4: ...l Automation TheAQ LOGIC P 4cancontrolupto4highvoltage 120 240V piecesofequipment upto3automatic valveactuators andconventionalandsolarheaters Bothmanualandautomatic programmed operation areavailable...

Страница 5: ...ential swimming pools up to 40 000 gallons 150 000 liters or the needs of most commercial pools up to 25 000 gallons 95 000 liters Check local codes for other restrictions The actual amount of chlorin...

Страница 6: ...fyouwanttooverridetheheatercooldown simplypresstheFILTERbutton againtoturnoffthefilterpump Two Speed Filter Pump If the pump is currently off simply press the FILTER button to turn on high speed opera...

Страница 7: ...e the automatic operation and operate the system manually you can put the system into Service or Service Timed mode by pressing the SERVICE button Pressing theSERVICEbuttononcewillswitchthesystemintos...

Страница 8: ...pstoprogramminganyfunction 1 Menu Pressthe Menu buttontogettothedesiredmenu Multiplepushesofthebutton willrotatethroughall5menusandreturntothestartingpoint 2 Presseitherkeytoscrollthroughthevariousite...

Страница 9: ...n lights weekdays aux1 all days or aux1 weekends or aux1 countdown aux1 weekdays aux2 all days or aux2 weekends or aux2 countdown aux2 weekdays valve3 all days or valve3 weekends valve3 weekdays super...

Страница 10: ...perature off 65 F 66 F 103 F 104 F off Move to previous next menu item The pool heater setting will only appear if the system has been setup for pool only or pool and spa operation and the heater cont...

Страница 11: ...e chlorinator output when the system is operating in spa only mode The actual amount of chlorine introduced into the spa is determined by this setting the amount of time the pool operates in spa only...

Страница 12: ...rol This menu will only appear if a wireless base station is connected to the Aqua Logic Wireless Channel 1 Reteach all wireless units Confirm Change to proceed Push to confirm the channel change Chan...

Страница 13: ...time clock will override the high speed timeclock see above there are several reasons why the pump will automatically switch to high speed operation during this programmed time period These include ma...

Страница 14: ...itions are suitable for operation If theAux relay is on during the programmed off time it may be because of freeze protection Also manual operation overrides the timeclock Refer to page 9 for general...

Страница 15: ...requiresthatyounavigatethroughtheConfigurationMenuandinputvarious information To access the Configuration Menu Configuration Menu Unlocked Configuration Menu Locked Press repeatedly until Configuratio...

Страница 16: ...Push to access heater options Toggle between Enabled and Disabled default Heater 1 Toggle between Enabled and Disabled default Heater Cooldown Toggle between Enabled and Disabled default Heater Exten...

Страница 17: ...or solar logic page 21 Also the solar temperature sensor must be installed This sensor is typically mounted near the collector array and is used to sense whether sufficient solar heat is available If...

Страница 18: ...suction valves to the spillover at the time of the programmed pool filtering time period or when the super chlorinate function is turned on The valves will remain in this position for the remain der o...

Страница 19: ...ck in the Timers Menu see Operations Manual Solar the aux relay operates a solar booster pump which will turn on when the filter pump in running and solar heat is available and the water is less than...

Страница 20: ...ch to the jets skimming for the last half of the hour Valve3 Interlock If Enabled this feature will override the function timeclock or in floor cleaner selected above and turn the valve off whenever t...

Страница 21: ...ss Initiate reset of all configuration parameters Move to previous next configuration menu item config not reset Are you sure to proceed Reset all configuration parameters Move to previous next config...

Страница 22: ...o go to the weekday settings Note During the programmed spa time the valves will automatically switch to the spa only position the filter pump will turn on and if the spa is not up to the desired temp...

Страница 23: ...n may be temporarily interrupted for a programmed spa operation Program a Timeclock 1 Pressthe Menu buttonrepeatedlyuntil TimersMenu isdisplayed 2 Pressthe buttonrepeatedlyuntilthe xxx alldays or xxx...

Страница 24: ...s operation can only be performed at the main Aqua Logic unit Both Ser vice and Service Timed disable all automatic programmed operations and allow manual operation from the main unit only The buttons...

Страница 25: ...Your water is properly balanced if the Si is 0 2 If the Si is below 0 2 the water is corrosive and plaster pool walls will be dissolved into the water If the Si is above 0 2 scaling and stainingwilloc...

Страница 26: ...Salt is not lost due to evaporation Type of Salt to Use Itisimportanttouseonlysodiumchloride NaCl saltthatisgreaterthan99 pure Thisiscommonfood quality or water softener salt and is usually available...

Страница 27: ...3 1600 160 73 187 85 213 97 240 109 267 121 293 427 133 195 320 453 145 207 347 480 158 219 373 507 170 231 400 533 182 243 1800 140 64 163 74 187 85 210 95 233 106 257 373 117 169 280 397 127 180 303...

Страница 28: ...9 5 16 4 7 4 22 2 10 0 17 2 8 0 23 3 10 5 6 0 2 7 4 0 2 7 6 0 2 7 6 0 2 7 8 5 3 9 7 0 3 2 9 0 2 2 10 0 4 5 10 0 4 5 14 2 6 3 11 0 5 0 16 0 7 2 13 0 5 9 18 0 8 1 14 0 6 4 19 0 8 6 15 0 6 8 20 0 9 0 5...

Страница 29: ...ate eye protection The level of the solution in the container should just reach the top of the cell so that the wire harness compartment is NOT submerged It may be helpful to coil the wiring before im...

Страница 30: ...lautomaticallyreturntonormaloperationafter 3 hours During service timed operation the service LED will flash and the time remaining will be dis played on the remote display keypad s Pressingthe Servic...

Страница 31: ...off part of its normal operating cycle Simply press either the or key to start a new cycle The Aqua Logic periodically reverses the polarity of the voltage applied to the cell in order to automatical...

Страница 32: ...or Short Circuit then check the wiring to the sensor and also make sure that the wires are secure in the terminal block in the Aqua Logic main unit Note that the solar sensor is displayed only when th...

Страница 33: ...Rite Aqua Trol or Aqua Logic electronics unit will be the sole determinant of the date of the initial system installation If a product is defective in workmanship or materials and is removed and retur...

Страница 34: ...r decrease pump filtration time Too high add muriatic acid Alkalinity 80 120 ppm Salt 2700 3400 ppm Add salt as required to increase Add baking soda to increase Stabilizer 60 80 ppm Add cyanuric acid...

Отзывы: