15
Pool/Spa Setup
+ to view/change
Pool/Spa Setup
Pool and Spa
Spa Spillover
Disabled
Filter Operation
Spa Spillover
+
+
+
+
>
>
>
>
>
>
>
>
Push to access Pool/Spa options
Rotates between Pool and Spa, Spa Only, and Pool Only (default) options
Toggle between Enabled and Disabled (default) Spa Spillover
Toggle between Pool Only and Spa Spillover (default) options
Move to previous/next configuration menu item
Move to next menu item
Move to next menu item
Move to next menu item
if “Pool and Spa” is selected
if “Pool and Spa” is selected
if “Spa Spillover” is enabled
and
P
ool/Spa Setup
If “Pool Only” or “Spa Only” are selected then the pool/spa valves are deactivated and
pushing the POOL/SPA button on the display/keypad will have no effect. If “Pool and Spa”
is selected, then the pool/spa suction and return valve actuators should be connected to the
Aqua Logic. Pressing the POOL/SPA button on the display/key pad will allow the home-
owner to alternate between pool and spa operation.
Spa Spillover
When spa spillover is “Enabled”, the homeowner will be able to rotate through “Pool Only”
(both suction and return valves switched to pool), “Spa Only” (both suction and return
valves switched to spa) and “Spillover” (suction valve switched to pool and return valve
switched to spa) by successive presses of the “Pool/Spa) button.
Filter Operation
If “Spa Spillover” is selected, the Aqua Logic will automatically switch the pool/spa suction
valves to the “spillover” at the time of the programmed pool filtering time period or when the
super-chlorinate function is turned on. The valves will remain in this position for the remain-
der of the super-chlorinate period. This option is usually preferable because both the pool
and spa water will be filtered and sanitized.
If “Pool Only” is selected, then the Aqua Logic will switch the pool/spa valves to the “pool
only” position during super chlorinate. This may be desirable on some systems with in-floor
cleaners because it allows the cleaner to operate all the time the pool is being filtered and/or
the super chlorinate is running.
Lights Config.
+ to view/change
Lights Function
Manual On/Off
+
+
>
>
>
>
Push to access Lights options
Rotates between Manual On/Off (default), Countdown Timer, and Timeclock
Move to previous/next configuration menu item
Move to next menu item
Lights Function
Manual On/Off
—the lights relay will alternate between turning on and off when the LIGHTS
button is pressed. There is no automatic control logic.
Countdown Timer
—the lights relay will turn on when the LIGHTS button is pressed. The
lights relay will turn off automatically after a programmed time (see Timers Menu in the
Operations Manual). The LIGHTS button can also be used to turn the output off. This
function is typically used to control spa jets where they can be turned on with the press of
a button and then they will turn off automatically at a later time.
Timeclock
– the lights will turn-on and turn-off at the times set for the lights timeclock in the
Settings Menu (see Operations Manual).