Selecting the discrimination mode

To select the discrimination mode, press the DISC MODE | DISC LEVEL button at the 

middle-left. A selection screen will appear to select between discrimination mode and 

discrimination depth.
Select the DISC MODE option and confirm with ENTER.

After you select and confirm the DISC MODE option, a selection screen with three options 

will appear - Mono, 2 and All, as shown on the next graphic.

As you can guess, selecting and confirming your choice is done by pressing the + and - 

buttons and then the ENTER button.

DISC MODE DISC DEPTH

SELECT

1. Mono-tone (mono)

In Mono discrimination mode, the detector produces sound for non-ferrous targets only. 

The signal from ferrous targets (iron) is masked. However, some rusty iron or big iron 

objects will produce sound, but with practice you’ll learn to securely distinguish the sound 

response from iron - it is harsh and choppy, not as sharp and obvious as the non-ferrous 

targets sound. The Spectrum VDI scale and the Target ID help to fast easy identify targets.
With the Iron Audio setting you can control the border of the signal masking. For example, 

if you don’t want to hear the response from foil, just push the + button to place the border 

to the right.
The Mono-tone mode is good for iron-polluted areas with lots of trash. Pay attention for 

every sharp signal and try not to pay attention to the chattering from the iron targets.
In Mono mode, the Golden Mask 5+ is a little bit deeper than in two-tone mode and han-

dles better the deep iron signals.

2. Two-tone (2)

In two-tone or bitonal mode, you hear both signals from ferrous and non-ferrous targets. 

Ferrous targets are indicated with a low sound, while the sound response from non-fer-

rous targets is indicated with high frequency sound. Again, you can control what to be in-

dicated as ferrous and what to be indicated as a ferrous signal with the Iron Audio setting.
The bitonal mode is used if you want to hear the non-ferrous metals. This is usual for new 

areas, where the presence of iron could give you valuable information about the place. 

Many people like to always hear the non-ferrous targets and this is not a problem with the 

Golden Mask 5+ even in very polluted areas, because of the fast response of the detector. 

To search in areas with lots of iron trash, use 18kHz and the Disc. Depth setting should be 

set at or near the maximum value of 15, the Gain should be set to 1 or 2 and the PowerBox 

to Low - with these settings the detector is even faster.

3. All Metal (All)

In All metal mode the discrimination is completely omitted and the detector is equally 

sensible to all type of metals. You hear the response from all the metals with a single tone. 

Identification of the target detected is possible by looking the TargetID numbers and 

Spectrum VDI graphic on the LCD screen.
In All metal mode the Golden Mask 5+ achieves the best depth of detection. The differ-

ence with the Mono mode is not as big as you’d like, however there is a difference and this 

tiny difference may be that additional depth you just need to reach a deep target. Unfor-

tunately, this mode is not comfortable in iron-polluted areas, but works great on places 

with few targets and you want to search at the maximum depth possible.
For maximum depth of detection in All Metal mode, set the frequency to 8kHz, Gain at 2 

and PowerBox to High.

DISC MODE

mono

All

2

Содержание 5+

Страница 1: ...Golden Mask 5 User Guide 18 kHz BITONAL GB 30 GAIN 1 THRESHOLD 25 P BOX LOW 69 IRON FOIL NICKEL COPPER SILVER...

Страница 2: ...dual frequency coils Wireless headphones WS105 included in the package 5 years warranty of the electronics board To offer the 5 years warranty the Golden Mask metal detectors are made with only top le...

Страница 3: ...ly from the handle part but we do not recoomend it because a plactic shim inside the locking screw could be lost or damaged Please be sure to have a minimum of 15 cm 6 inch of the third section inside...

Страница 4: ...he ENTER button A reset is REQUIRED every time after you change the working frequency or the PowerBox settings If the surrounding temperature is changing quickly the detector may become nervous In thi...

Страница 5: ...bove this border are shown with positive numbers The Iron Audio setting is shown with bi color bar just bellow the Spectrum VDI scale The black part of the Iron Audio bar shows targets that will sound...

Страница 6: ...es better the deep iron signals 2 Two tone 2 In two tone or bitonal mode you hear both signals from ferrous and non ferrous targets Ferrous targets are indicated with a low sound while the sound respo...

Страница 7: ...select the desired value with the and buttons and confirm with ENTER Ground balance GB The ground balance is a setting that compensates for different ground conditions There are soils with no to very...

Страница 8: ...nd Balance To automatically adjust the ground balance press the ground balance GB button on the bottom left corner of the control panel then select the Auto option from the ground bal ance menu and co...

Страница 9: ...ptions are 0 1 and 2 The higher the number the greater the overall signal amplification But be aware on mineralization higher number of the Gain does not always mean deeper penetration of the signal O...

Страница 10: ...hen try the above two options The PowerBox setting is related to the working frequency In other words you could set different values for the two working frequencies The detector will remember the sett...

Страница 11: ...activated a small icon appears below the battery icon on the main screen to show you the backlight is on when Controlling the LCD screen contrast You can change the LCD screen contrast To do this sho...

Страница 12: ...e Automatically adjust from 6V 15V Max voltage with no load 20V Rated Current 500mA 450mA 600mA Trickle Current 35 50MmA Pulsel ratio 1 20 10mA Short Circuit Current 10 20mA Battery repairingl Current...

Страница 13: ...ference EMI fields that will disturb the detector and you may think something s wrong On sites with not too many targets try to use the All metal mode this will give you 2 3 cm more depth If you canno...

Страница 14: ...Golden Mask 5 User Guide GMD www goldenmaskdetectors com Golden Mask Official Distributor 26...