INSTALLATION INSTRUCTIONS
In planning the installation for the fireplace, it is necessary to determine where the
unit is to be installed, the routing of the B-type vent system, and whether optional
accessories are to be used. Gas supply piping should also be planned.
HD5030-TV OR HD4240-TV (with the use of the Outside Air Kit) can be installed
in a bedroom (in the United States) which has a total volume of unconfined space
appropriate to the particular installation. Refer to the National Fuel Gas Code ANSI
Z223.1/NFPA 54 - (current edition), the Uniform Mechanical Code - (current edition),
and Local Building Inspector for the options allowed in obtaining an effective bedroom
volume of unconfined space.
The fireplace can be mounted on any of the following surfaces:
1. A flat combustible surface
2. A raised wooden platform
3. Four (4) corner supports
(Example: four (4) concrete masonry blocks.) These supports must be positioned so
they contact all four corner edges on the bottom of the unit.
If the fireplace is to be installed on carpeting, tile, or other combustible material other
than wood flooring, the fireplace must be placed upon a metal or wood panel extending
the full width and depth of the unit.
Fireplace framing can be built before or after the fireplace is set in place. Framing
should be positioned to accommodate wall covering and fireplace facing material.
The fireplace framing should be constructed of 2 x 4 lumber or heavier. The framing
headers may rest on the fireplace standoffs. Refer to Figure 7.1 for fireplace and
framing reference dimensions.
CAUTION: VERIFY FIREPLACE DIMENSIONS, FRAMING METHODS AND WALL
COVERING DETAILS BEFORE FRAMING CONSTRUCTION BEGINS.
Determine the exact position of the fireplace so that the vent run can be planned.
Figure 2.1 shows possible locations for the fireplace; inside of a room, flush mount
in a chase, or installed in a corner. Using a level, make sure the fireplace is properly
positioned and squared.
WARNING: DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE
LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE.
6
Содержание EL GRANDE
Страница 11: ...LOG PLACEMENT FOR MODEL HD5030 TV LOG SET STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 11 ...
Страница 12: ...STEP 7 STEP 8 FINAL ARRANGEMENT 12 ...
Страница 13: ...13 LOG PLACEMENT FOR MODEL HD4240TBF STEP 1 STEP 2 STEP 3 STEP 4 FINAL ARRANGEMENT ...
Страница 15: ...14a Enervex ADC 100 Draft Switch connection 50D50 843 Enervex ADC 100 Draft Switch connection ...
Страница 16: ...14B 14B ...