background image

CAUTION: DURING THE INITIAL PURGING AND SUBSEQUENT 

LIGHTING, NEVER ALLOW THE GAS VALVE CONTROL KNOB 

TO REMAIN DEPRESSED IN THE A “PILOT” POSITION 

WITHOUT PUSHING THE RED IGNITOR BUTTON AT LEAST 

ONCE EVERY SECOND.  

WARNING:

 

CHILDREN AND ADULTS SHOULD BE ALERTED 

TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND 

SHOULD STAY

 

AWAY TO AVOID BURNS OR CLOTHING

 

IGNITION. YOUNG CHILDREN SHOULD BE

 

CAREFULLY 

SUPERVISED WHEN THEY ARE IN

 

THE SAME ROOM AS  

THE APPLIANCE.

 

IMPORTANT: TURN OFF GAS BEFORE SERVICING  

APPLIANCE. IT IS RECOMMENDED THAT A COMPETENT 

SERVICE TECHNICIAN PERFORM THESE CHECKUPS AT  

THE BEGINNING OF EACH HEATING SEASON.

WARNING: THE FLOW OF COMBUSTION AND VENTILATION 

AIR MUST NOT BE OBSTRUCTED.

When lit for the first time, the appliance will emit a slight odor for 
an hour or two.  This is due to paint and lubricants used in the 
manufacturing process.  The main burner flame characteristics 
are steady, not lifting or floating.  Typically, the top 3/4 inch of the 
pilot generator should be engulfed in the pilot flame.  A periodic 
check of these characteristics is necessary.

CAUTION:  THE LOGS CAN GET VERY HOT!  HANDLE ONLY WHEN COOL

MAINTENANCE INSTRUCTIONS

14

OPERATING GUIDELINES

Upon completing the gas line connection, a small 
amount of air will be in the lines. When first lighting 
the pilot light, it will take a few minutes for the 
lines to purge themselves of this air. Once the 
purging is complete, the pilot and burner will light 
and operate as indicated in the instruction manual. 
Subsequent lighting of the appliance will not require 
such purging.

IMPORTANT: 

THE APPLIANCE 

AREA MUST BE KEPT CLEAR  
AND FREE FROM COMBUSTIBLE 
MATERIALS, GASOLINE AND  
OTHER FLAMMABLE VAPORS  
AND LIQUIDS.

Visually inspect pilot periodically.  
Brush or blow away any dust or  
lint accumulations.  If pilot orifice  
is plugged, disassembly may be 
required to remove any foreign  
material from orifice or tubing.

Venting system should be periodically 
examined by a qualified service 
technician or agency to ensure proper 
air flow.

WIRING DIAGRAM

14

Содержание EL GRANDE

Страница 1: ...d with the fireplace Burning other items could cause a fire hazard or injury For best results Natural Gas pressure should be 7 to 12 W C and 11 W C for Propane Gas To simulate real wood burning the gas burner is designed to burn a yellow flame It is normal for the logs to soot up The soot can be easily removed with a vacuum cleaner or soft brush Check the label on the firebox to as sure the proper...

Страница 2: ... Building Codes and Safety Standards 4 Piping and Gas Pressure Requirements 5 Installation Instructions 6 Log Placement 11 Operating Guidelines 14 Lighting Instructions 15 Trouble Shooting 17 Replacement Parts 19 INSIDE ROOM FLUSH MOUNT CHASE CORNER MOUNT B HD4240 TV A 97 B 69 HD5030 TV A 102 B 73 1 2 A ...

Страница 3: ...HD5030 TV AND HD4240 TV interior view Pan Burner Outside Air Control Knob Damper Control Lever Pilot Light Valve Access Panel 3 Gas Line Access Outside Air Port Outside Air Control Knob On Off Switch ...

Страница 4: ...UEL NOTE INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC IT IS IMPERATIVE THAT THE UNITS CONTROL COMPARTMENT BURNERS AND CIRCULATING AIR PASSAGE WAYS BE KEPT CLEAN TO PROVIDE ADEQUAT...

Страница 5: ...OPERATION OF THIS UNIT ON LP GAS WITHOUT AN APPROVED REGULATOR AT THE TANK WILL LEAD TO GAS LEAKS AT THE CONTROL VALVE WITH POSSIBLE FIRE OR EXPLOSION Include a manual shut off valve and union in the line so the control or heater may be disconnected for servicing Include a drip leg and a plugged 1 8 N P T tapping into the line also The tapping must be accessible for the test gauge connection immed...

Страница 6: ... unit If the fireplace is to be installed on carpeting tile or other combustible material other than wood flooring the fireplace must be placed upon a metal or wood panel extending the full width and depth of the unit Fireplace framing can be built before or after the fireplace is set in place Framing should be positioned to accommodate wall covering and fireplace facing material The fireplace fra...

Страница 7: ... 34 1 4 30 1 2 76 1 2 73 42 1 7 47 1 4 RIGHT SIDE GAS LINE KNOCK OUT FRONT EDGE OF FIREPLACE AIR KIT 8 1 2 INSTALLED AFTER FIREPLACE IS POSITIONED MINIMUM FRAMING DIMENSIONS LEFT SIDE AIR SAME POSITION FROM FRONT EDGE AS RIGHT SIDE FRONT EDGE OF FIREPLACE RIGHT SIDE GAS LINE KNOCK OUT AIR KIT 11 2 1 2 9 4 30 42 1 2 59 1 2 12 1 4 21 1 2 58 3 4 40 1 4 30 1 2 66 1 2 66 50 58 3 4 1 7 41 HD5030 TV 4 50...

Страница 8: ... point of the roof opening see below 2 If the chimney penetrates the roof farther than 10 from its peak measure from the center line of the chimney to a point 10 away between the chimney and the peak of the roof The top of the chimney must be at least 36 above the highest point of the roof opening see below 3 The 10 Rule of Thumb is a guide for calculating chimney height that works under most cond...

Страница 9: ...t is a minimum of 12 inches above top of fireplace opening Figure 8 2 Non combustible material used between top of opening and mantle must not exceed 3 in depth Caution All joints between the finished wall and the fireplace surround Top and Sides can only be sealed with non combustible material Only non combustible material can be applied as facing to the fireplace surround Figure 8 2 Hearth Extension...

Страница 10: ...wing embers over main burner pan and CEBB tube Note Be sure to create a gap between the main burner pan s glowing embers thus enhancing a front curl of flame from the main burner 4 Pour black rock around sides of pan for picture frame effect Note On L P models be careful not to pour black rock over brass air mixer attached to burner pan 5 Position log grate against rear wall of fireplace and cente...

Страница 11: ...LOG PLACEMENT FOR MODEL HD5030 TV LOG SET STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 11 ...

Страница 12: ...STEP 7 STEP 8 FINAL ARRANGEMENT 12 ...

Страница 13: ...13 LOG PLACEMENT FOR MODEL HD4240TBF STEP 1 STEP 2 STEP 3 STEP 4 FINAL ARRANGEMENT ...

Страница 14: ...ifting or floating Typically the top 3 4 inch of the pilot generator should be engulfed in the pilot flame A periodic check of these characteristics is necessary CAUTION THE LOGS CAN GET VERY HOT HANDLE ONLY WHEN COOL MAINTENANCE INSTRUCTIONS 14 OPERATING GUIDELINES Upon completing the gas line connection a small amount of air will be in the lines When first lighting the pilot light it will take a...

Страница 15: ...14a Enervex ADC 100 Draft Switch connection 50D50 843 Enervex ADC 100 Draft Switch connection ...

Страница 16: ...14B 14B ...

Страница 17: ...ss controls open valve access panel 3 Turn the control to the OFF position To do this you must turn the knob clockwise to the pilot position and then press in and continue turning clockwise to the OFF position 4 WAIT FIVE 5 MINUTES TO CLEAR OUT ANY GAS If you then smell gas STOP Follow B in the safety information above If you don t smell gas go to next step 5 The pilot does not require accessing f...

Страница 18: ... Telephone gas company and fire department Ask instructions Before hanging up give your name address and phone number DO NOT go back into building If your L P tank runs out of fuel turn off gas at the appliance After L P tank Is refilled appliance must be re lit according to manufacturer s instructions If the gas control has been exposed to WATER in any way DO NOT try to use it It must be replaced...

Страница 19: ...at electrode off pilot and trigger the red button again If pilot lights an improper gas air mixture caused the bad lighting and a longer purge period is recom mended If pilot will not light check gap at electrode and pilot should be 1 8 inch to have a strong spark If OK replace pilot C No gas or low gas 1 Check remote shut off pressure valves from fireplace usually there is a valve near the firepl...

Страница 20: ...nd TP terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position pilot lit and ON OFF switch OFF Replace faulty generator if reading is below specified minimum B Defective valve 1 Connect the millivolt meter probes to the TH TP and TP terminals on the gas valve Turn knob to pilot position depress and light pilot light If meter reading is greater ...

Страница 21: ...HD 125 Vermiculite 2 Bags LP 9 HD 109 Thermopile 26 HD 126 Volcanic Rock 10 HD 110 Pilot Assembly Bracket 27 HD 127 Temp Limit Switch 11 HD 111 Burner Orifice NAT 28 HD 128 Damper Switch 12 HD 112 Burner Orifice LP 29 HD 129 Silica Sand NAT 13 HD 113 Burner Pan Assembly 30 HD 130 Glowing Embers 14 HD 114 Log Grate 15 HD 115 Step 1 Left Log 16 HD 116 Step 1 Right Log 17 HD 117 Step 1 Back Log ITEM ...

Страница 22: ...9 HD 109 Thermopile 26 HD 126 Volcanic Rock 10 HD 110 Pilot Assembly Bracket 27 HD 127 Temp Limit Switch 11 HD 211 Burner Orifice NAT 28 HD 128 Damper Switch 12 HD 112 Burner Orifice LP 29 HD 129 Silica Sand NAT 13 HD 213 Burner Pan Assembly 30 HD 130 Glowing Embers 14 HD 214 Log Grate 15 HD 215 Step 4 Bottom Log 16 HD 216 Step 4 Top Log 17 HD 217 Step 2 Log ITEM PART DESCRIPTION ITEM PART DESCRIP...

Страница 23: ...e first year after installation Golden Blount may discharge its entire warranty liability by refunding the price of the product Products made by other manufacturers sold with the fireplace or thereafter are not covered by this limited warranty The use of other unauthorized components will make this warranty null and void This limited warranty will be void if the appliance is not installed by a qua...