Trouble Shooting your Dehumidifier

Problem

Cause

Solution

The Dehumidifier will not 
turn on

The power is not connected

Insert plug into mains power 
supply and turn unit on

The Dehumidifier is not 
extracting water

The water tank is full

Remove the water tank and 
empty water

The water tank is not in its 
correct position

Remove water tank and 
replace it correct position

The air filter is clogged

Clean the air filter as per 
instructions in user manual

The temperature or relative 
humidity in the room is too 
low

It is normal for the 
Dehumidifier not to operate 
in low humidity or low 
temperatures

The Dehumidifier operates, 
but reduces the relative 
humidity in the room by 
small amounts

The room which the 
Dehumidifier is operating in 
is too large

Recommend using a 
Dehumidifier with a larger 
capacity

There are too many sources 
of humidity

Recommend using a 
Dehumidifier with a larger 
capacity

The room has too much 
ventilation

Reduce the number of 
ventilation sources (i.e. close 
windows, doors, etc.

TECHNICAL SPECIFICATION

Model No:

GD215

GD270

GD285

Supply:

220-240VAC 50Hz

220-240VAC 50Hz

220-240VAC 50Hz

Wattage:

260W

410W

480W

Unit Capacity(30

/80%RH):

12.0L/day max

16.0L/day max

20.0L/day max

Tank Capacity:

4.0L

4.0L

4.0L

Refrigerant:

R134a/110g

R134a/105g

R134a/115g

SUPPORT AND TECHNICAL ADVICE

Goldair

New Zealand

Monday 

Friday 8am-5pm

Phone +64 (0)9 917 4000
Phone 0800 232 633
[email protected]

Goldair

Australia

Monday 

Friday 8am-5pm

Phone +61 (0)3 9365 5100

Phone 1300 465 324

[email protected]

PROOF OF PURCHASE
To receive warranty retain receipt as proof of purchase.

Содержание GD215

Страница 1: ......

Страница 2: ...This page is intentionally left blank ...

Страница 3: ... To reduce the risk of fire keep textiles curtains or any flammable material a minimum distance of 1metre from the air outlet General Care and Safety Guide Use only the voltage specified on the rating label of the appliance The dehumidifier must not be located immediately below a socket outlet Keep all objects at least 1 metre from the front sides and rear of the appliance This appliance is intend...

Страница 4: ... off Do not remove plug from power socket by pulling cord always grip plug Do not place cord under carpet or cover with rugs or furniture Arrange the cord so it cannot be tripped over Don t place appliance on bedding or on thick long carpet where the openings may get blocked Switch off and use handle provided when moving Do not place appliance close to radiant heat source Do not insert or allow fo...

Страница 5: ... dehumidifier is covered or positioned incorrectly WARNING Never leave this dehumidifier unattended Ensure dehumidifier is on a flat stable heat resistant surface Once the dehumidifier is in a safe operating position and all switches are in the off position insert the power plug into the mains outlet CAUTION Ensure the power cord is not tight because if pulled it may partially pull the plug from t...

Страница 6: ...rst allow at least 10 minutes before switching the unit back on If the unit fails to operate after it has been switched off at the mains before allowing to power Off switch off the power at the power supply leave the unit to stand for 10 minutes Switch the power supply back on then Press the On button again on the unit the unit should now operate The recommended operating temperature range is 15 t...

Страница 7: ...Once the unit has completed defrosting the compressor will turn back on and continue to dehumidify PERMANENT WATER DRAINAGE It is possible to connect a drainage tube not supplied to the appliance for permanent water drainage If this option is desired you will need to purchase a suitable PVC tube from your local hardware retailer Goldair does not hold tubes as spare parts Connect the drainage hose ...

Страница 8: ...e removed regularly by unplugging the appliance and vacuum cleaning the air vents and grills Use a damp cloth not wet to wipe the exterior of the dehumidifier to remove dust and dirt Never use solutions such as petrol thinners or polishing agents Ensure the dehumidifier is dry before plugging back into the mains supply TO CLEAN THE AIR FILTER Unplug the appliance from the mains supply Remove the f...

Страница 9: ...s The room which the Dehumidifier is operating in is too large Recommend using a Dehumidifier with a larger capacity There are too many sources of humidity Recommend using a Dehumidifier with a larger capacity The room has too much ventilation Reduce the number of ventilation sources i e close windows doors etc TECHNICAL SPECIFICATION Model No GD215 GD270 GD285 Supply 220 240VAC 50Hz 220 240VAC 50...

Страница 10: ...under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guarantees...

Страница 11: ...This page is intentionally left blank ...

Страница 12: ......

Отзывы: