background image

Operating your Dehumidifier 

CONTROLS 
Press  

  or  

 button to set the desired 

humidity level in the room, which can be set from 
30% to 90% at 5% intervals or on ‘CO’ for 
continuous dehumidification.  
Once the rooms humidity is lower than the selected 
humidity by 2%, compressor will stop and fan stops 
working 3 minutes later; When environment humidity 
is equal to or higher than the selected humidity by 
3%, compressor will restart. 
 
TIMER 
The timer can be set to turn the unit On or Off. 
To set to turn on; Press the Timer button when the 
unit is turned off. Press again until you reach the 
amount of hours you would like to elapse before the 
appliance turns on (1-24) 
To set the timer to turn off: Press the Timer button 
when the unit is turned on. Press again until you 
reach the amount of hours you would like to elapse 
before the appliance turns off (1-24) 
 
WATER TANK FULL 
A  beep  signal  will  sound  15  times.  The  WATER 
FULL  indicator  light  will  illuminate  on  the  control 
panel.   
The compressor will stop automatically, and the unit 
will stop dehumidifying. 
Empty the water container and replace it in the 

correct position. If the drainage tank is dirty, wash it 
with cold or lukewarm water. Do not use detergent, 
scouring pads, chemically treated dust cloths, 
gasoline, benzene, thinner, or other solvents, as 
these can scratch and damage the tank and cause 
water leakage  
When replacing the drainage tank, press the tank 
firmly into place with both hands. If the tank is not 
positioned properly, the “TANK FULL” sensor will be 
activated, and the dehumidifier will not operate. 
Do not remove the float from the water tank. The 
water full sensor will no longer be able to detect the 
water level correctly without the float and water may 
leak from the water tank. 
 
The  Dehumidifier  will  continue  dehumidifying  when 
the  compressor  automatically  restarts  after 
approximately three minutes. 
 
 
 
 
 

WARNING Keep all objects at least 1 metre 

from the front, sides and rear of the appliance.

 

 

WARNING: In order to avoid overheating, do 

not cover the appliance. 
 
WARNING: Never leave this appliance 

unattended. 

 
Leave  the  appliance  to  stand  for  one  hour  after 
transport or after the unit has been on its side before 
connecting it to the mains supply to let the refrigerant 
settle. 
 
Ensure  that  the  water  container  is  positioned 
correctly. 
 
Ensure  all  external  windows  and  doors  are  closed 
before turning on the unit. 
 
Plug  into  power  supply  and  switch  on  at  the  mains.  
The  dehumidifier  will  display  the  current  humidity 
level on the control panel. The POWER indicator light 
will illuminate to show power to the unit.  
The  louvre  to  be  opened  by  lifting  the  louvre  at  the 

opening and pushing it upward. 
 
To  turn  the  Dehumidifier  on,  press  the  POWER 
button.  
 
 
 
 
 
 
 
 

Always  choose  a  safe  location  for  the  Dehumidifier,  keeping  in  mind  the 
safety  precautions  outlined.  Ensure  all  packaging  has  been  removed  from 
the  unit  before  use.  This  appliance  requires  no  installation,  it  should  be 
used solely as a portable appliance. 

This dehumidifier is designed to provide optimum performance at 35°C -15°C but it is still effective down to 
5°C. Ultimately the performance of this dehumidifier is dependant on the amount of moisture or water vapour 
in the air. 

   

Содержание GD190

Страница 1: ......

Страница 2: ...ound the appliance as this may cause the insulation to weaken and split Always ensure that all cord has been removed from any cord storage area and is unrolled before use 18 It is recommended that this appliance is plugged directly into the wall socket Power boards are not rated to supply power to high wattage appliances 19 A correctly specified undamaged extension cord may be used with this appli...

Страница 3: ... 9 Supply cord Attention This Dehumidifier is rated to extract 10L per day in an environment of 80 humidity and temperature of 30 C This is the world wide standard for rating dehumidifiers In New Zealand we do not have climatic conditions with this humidity and high temperature Accordingly the extraction levels will be lower ...

Страница 4: ...nsor will be activated and the dehumidifier will not operate Do not remove the float from the water tank The water full sensor will no longer be able to detect the water level correctly without the float and water may leak from the water tank The Dehumidifier will continue dehumidifying when the compressor automatically restarts after approximately three minutes WARNING Keep all objects at least 1...

Страница 5: ...down completely before cleaning Use a damp cloth not wet to wipe the exterior of the Dehumidifier to remove dust and dirt Use a vacuum cleaner to remove dust and fluff from around the grills Never use solutions such as benzene thinners or polishing agents Ensure the Dehumidifier is dry before plugging back into the mains supply TO CLEAN THE AIR FILTER Unplug the Dehumidifier from the mains supply ...

Страница 6: ...n doesn t work Is the air filter clogged Clean the air filter as instructed under Cleaning the dehumidifier Is the intake duct or discharge duct obstructed Remove the obstruc on from the discharge duct or intake duct No air is discharged Is the air filter clogged Clean the air filter as instructed under Cleaning the dehumidifier Opera on is noisy Is the unit lted or unsteady Move the unit to a stable st...

Страница 7: ... under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guarantee...

Страница 8: ......

Отзывы: