4)  Set  time unit and duration for each dose, pause time 

between doses, set number of cycles. 

5)  Return to main screen. 

Number of 

Cycles

Stop

Start

Dispense 

Duration

Dispense 

Duration

1

0

Dispense 

Duration

N

Lag Time

Lag Time

Stop

Press

 

START/STOP

Stop

Run N times

 

Figure 17. Dispense Cycle Setting 

To run Time Dispense: 

1)  Press 

DIRECTION 

key to set  the running direction, 

clockwise or counterclockwise. 

2)  Press 

START/STOP 

key to start dispensing. 

3)  During operating, press 

START/STOP

 key to stop the drive 

anytime when necessary. 

4)  A footswitch can be used to start/stop pump. 

7.7

 

Logic Level 1 Control Mode (footswitch) 

Use external logic level signal to  control start and stop. Use the 
keypad to control direction and speed. 

lev1

32.5rpm

 

Figure 18. Logic Level 1 Control Mode 

1)  Switch the power off. Wire the DB15 connector as shown on 

Figure 19

 or 

Figure 20

, and connect it to the DB15 port on 

the rear of the pump. 

Содержание BT103S

Страница 1: ...GOLANDER BT103S Variable Speed Pump Operating Manual info golanderpump com http golanderpump com 1 678 587 8806...

Страница 2: ...ld get caught in drive mechanism Warning Tubing breakage may result in fluid being sprayed from pump Use appropriate measures to protect operator and equipment Warning Remove power from pump before at...

Страница 3: ...rating 10 7 2 Power Connection 11 7 3 Change Control Mode 11 7 4 Internal Control Mode 12 7 5 External Control Mode 12 7 6 Time Dispense Mode 14 7 7 Logic Level 1 Control Mode footswitch 15 7 8 Logic...

Страница 4: ...ube material Suction lift and priming can be up to 8m water column at sea level It can handle the most shear sensitive of fluids like latex or firefighting foam with low shearing It is capable of runn...

Страница 5: ...nction is not available for US Europe Market Circuit boards with conformal coating to achieve dust and moisture proof Ultra strong anti electromagnetic interference feature wide voltage design suitabl...

Страница 6: ...r BT103S Manual 3 3 Components and Connectors Power Switch Cooling Fan DB15 External Control Interface Power Connector LCD Display Keypad Pump Head Mounting Bracket Coupler Figure 1 Components and Con...

Страница 7: ...y When press it shortly the last digit of the value will decrease 1 Hold the key to decrease the value quickly MENU Key When on main screen press the MENU key to enter the setting menu When on the set...

Страница 8: ...hen the drive is not running press the number to input desired value in the pop up window See the picture below Int 32 5rpm A B G C D E F Figure 3 Display screen 4 2 1 A Control Mode It displays curre...

Страница 9: ...d speed Logic Level 2 Control Mode footswitch and direction switch Use external logic signal to control start stop and direction Use the keypad to adjust speed 4 2 2 B Running State It shows current d...

Страница 10: ...mmunication state 1 Communication disconnected Connected pump number is set to 1 Figure 8 Communication state 4 2 7 G Rotating Speed State It shows the current rotating speed rpm When the drive is run...

Страница 11: ...p Setting 10 Language Menu 11 WIFI Reset Menu 12 Contrast Menu 13 Reset Circles Menu Second 2 Disp Time 3 Pause Time Unit 4 Pause Time 6 Reverse Angle 7 Max Speed 600 rpm 8 Pump NO 1 9 Beep Setting En...

Страница 12: ...ART STOP is pressed otherwise pump will stop when it finishes dispensing the set number of cycles Figure 17 Note 6 Reverse Angle To minimize the drip after a dispense the drive can reverse direction t...

Страница 13: ...Ground of external power 9 AGND Negative of analog signal input 10 12V Positive of internal 12V power source 11 GND Ground of Internal power source 12 CW Internal direction signal output 13 RS_W Exter...

Страница 14: ...Please plug the power cord into the IEC Power Connector on the rear of the pump and plug the opposite end of the power cord into an electrical outlet Flip the power switch located on the rear of the...

Страница 15: ...r stop pump 6 Press PRIME key pump will run at maximum allowed speed Int 32 5rpm Int Normal Speed Full Speed Figure 11 Normal vs Full Speed 7 5 External Control Mode On this mode use external logic le...

Страница 16: ...Internal 12VDC Power Source 2 Turn on the power switch Pump will display the main screen 3 Press MODE key to change the mode to External Control mode ExtV or ExtI shown on the screen 4 Close the exter...

Страница 17: ...d automatically by setting duration for each dose pause time between doses and number of cycles When dispensing the display will show the dispensing time or lag time that has passed 1 2s on the figure...

Страница 18: ...o set the running direction clockwise or counterclockwise 2 Press START STOP key to start dispensing 3 During operating press START STOP key to stop the drive anytime when necessary 4 A footswitch can...

Страница 19: ...een 3 Press MODE key to change the mode to Logic Level 1 control mode shows lev1 on the screen 4 Press UP or DOWN key to adjust the speed 5 Press DIRECTION key to change the rotating direction 6 When...

Страница 20: ...s shown on Figure 22 or Figure 23 and connect it to the DB15 port on the rear of the pump 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 RS_W CW_W Figure 22 Logic Level 2 Control with Internal 12V Power Source 1...

Страница 21: ...h CW_W is closed the drive will be running in counterclockwise direction 7 9 Communication Mode The RS485 interface supports standard MODBUS protocol Pump can communicate with external device via the...

Страница 22: ...hen the speed is between 0 1 and 100 rpm the speed resolution is 1 rpm when the speed is above 100 rpm The speed can be set by pressing the UP or DOWN key Press the UP or DOWN key shortly the last dig...

Страница 23: ...he current Wi Fi manually enter the Wi Fi password after clicking on the Confirm button wait about 20 seconds you will see the added device lnt 32 5rpm Figure 27 Wi Fi connected 8 Maintenance 8 1 Warr...

Страница 24: ...he driver board 3 Check the wire connection between the driver and the main board 4 Check the power voltage for the pump 3 Hardware Motor only runs in one direction Check the connection between the dr...

Страница 25: ...ecure 9 Software External control does not work Check if pump is on External Control Mode 10 Software RS485 does not work right 1 Check if the display shows the communication is ready 2 Reset the addr...

Страница 26: ...speed L Flow pump F Dispensing pump BT102S 100 rpm BT103S 100rpm 11 Specifications Suitable pump heads YZ15 YZ25 YT15 YT25 DG1 DG2 DT10 18 DT10 28 Speed resolution 0 1 100 rpm 0 1 rpm resolution 100...

Отзывы: