SmartBox
®
4 LAN / SmartBox
®
4 LAN PRO
part no. 28 410 57 a
17 / 28
Menu
Setting
Description
13.Rounding Automatically
non rounded
20L
50L
100L
200L
500L
1.000L
Default settings:
minimal increments
Rounding increments in relation to the set volume
set with [+] / [-] keys
14.Exit
Press [Enter] to return to display mode
15.Network
DHCP: YES
DHCP: NO
Select whether to automatically obtain the IP
address or directly specify it.
Detailed description of all the adjustable
parameters look at CONFIGURING THE NETWORK COMMUNICATION.
16.Sort
tanks
with
SmartBox 4
LAN
ESC
Exit the menu
Delete Tank n
Delete the registered Tank
T2<->T3
Replace Tank 2 for Tank 3
T2<->T4
Replace Tank 2 for Tank 4
T3<->T4
Replace Tank 3 for Tank 4
16.Sort
tanks
with
SmartBox 4
LAN PRO
ESC
Exit the menu
Delete Tank n
Settings for tank n are deleted and reset to default
settings (tanks 2, 3, 4)
17.Input/
Output
Alarm-In:
Sets the function of the alarm contact input
Closing
Opening
Deactiv
Closer alarm. Input closed
Alarm
Opener alarm. Input contact opens
Alarm
Sets the alarm input functionless
Data-Out:
Defines the data output on the output adapter slot
Tank: 1
Tank:1-4
For data output a selection can be made between
•
Output single tank 1, 2, 3 or 4
for analogue
adapter
•
Output “1-4”
all tanks are output sequentially
via digital slot-in adapter – e.g. for PC set LAN
18.Language Language:
German, English, French
[+] / [-] / [Enter]
Names:
ESC
[+] / [-] / [Enter]
Name Tank 1
: Suggested name
Letters can be changed with [+] / [-] / [Enter]
19.Exit
Back to display mode
20.LCD
display
Contrast: 24
Set the contrast of the LCD display
21.Device
info
Software version: V6.00
(e. g.)
Serial number: Tank 1: SN=1234
(e. g.)
Gain:X0=4.05mA B=1268
(Tank 1)