part no. 28 410 57 a
Example of switch point setting for Active (with
hysteresis):
Enter switching points as % values from 01 - 99 (and/or
enter as °C value from -99 to +99 only for
level probe
with temperature measurement
)
deactive
activate with [+] / [-] to
active
press [Enter] to confirm
On 10%
ON: set with [+] / [-]
[Enter]
Off 12%
OFF: set with [+] / [-]
[Enter]
On +0°C
ON: set with [+] / [-]
[Enter]
Off +0°C
OFF: set with [+] / [-]
[Enter]
Deactivate
the relay via
deactive
or input of
0%
or
0°C
(for
On
and
Off
).
ON ______%
OFF ______%
ON ______°C
OFF ______°C
7.Exit
SmartBox 4 PRO
Press [Enter] to return to display mode
8.Exit
Press [Enter] to return to display mode
After performing entry steps 1 - 7, the programming process is completed.
After confirmation of step “8.Exit“, the device automatically returns to default display mode;
the current tank content is shown in the display.
Special functions are available under entry steps 9 to 24.
After the end of setup, do not forget to replace the housing cover!
After completing the ASSEMBLY and PROGRAMMING, carrying out a function check is
recommended (FUNCTION CHECK section).
EXAMPLES FOR PROGRAMMING
Example 1: Basement tank for 6.000 litres fuel oil, litre display, linear steel tank
Inner height 165 cm, (fill level 125 cm)
SmartBox
®
4 LAN
with standard probe 0 - 250 mbar
Step
Entries / selection
1.Measure probe
250mbar
2.Liquid
Heat.oil
3.Tank shape
Linear
4.Tank volume
6.000L
(set with [+] / [-] keys)
5.Tank height
165.0cm
(set with [+] / [-] keys)
5b.Filling limit
95%=157cm
(set with [+] / [-] keys)
6.View
View details
FiPercnt
display 2. line - (set with [+] / [-] keys)
7.Relay
Deactive
8.Exit
press [+] to go to
15.Network
DHCP: Yes
16.-18.
press [+] to go to
19.Exit
press [Enter] to see the indication
Heat.oil 4.550L
-1.150L