Field of application / operating principle
Combinations of bursting discs and safety valves are used in a wide range of
applications in which the tightness of the system in ongoing operation is particularly
important.
Furthermore, once the bursting disc responds and the pressure has been reduced
to a level low enough for safe operation of the system, the system is sealed again
reliably by the safety valve.
The bursting disc protects the safety valve and ensures, for example, that it does
not develop leaks due to contamination and/or does not open prematurely.
3
Technical Data
DN
20
25
32
Inlet / x outlet
G¾“ x G 1 1/4“
G1“ x 1 1/2“
G 1 1/4“ x G 2"
Min. flow diameter in mm
18
23
30,3
Set pressure [bar]
≥
3,2 to 25,0
≥
3,0 to 25,0
≥
2,0 to 16,0
Fluid / fluid group
gases and vapours / 1 and 2
DN
20
25
32
TC(R)-(SGK)KUB
-0,75
-1
-1,25
Nominal diameter DN
(clear width D2) in mm
26,9
33,7
42,4
Set pressure at 22°C [bar]
≥
3,2 to 25,0
≥
3,0 to 25,0
≥
2,0 to 16,0
Permissible operating
temperature TS [°C]
-40 °C to +200 °C
Fluid / fluid group
gases and vapours / 1 und 2
Safety Valve 451r / 851r
Bursting disc TC(R)-(SGK)KUB
Содержание 451r
Страница 1: ...451r 851r...
Страница 26: ...1 www goetze armaturen de Assembly and maintenance instructions 451r 851r 451r 851r 2 zh...
Страница 28: ...www goetze armaturen de Assembly and maintenance instructions 451r 851r DIN EN ISO 4126 3 1 2 5 4 3 1 2 3 4 5...
Страница 29: ...www goetze armaturen de Assembly and maintenance instructions 451r 851r 6 10Nm 5...
Страница 30: ...www goetze armaturen de Assembly and maintenance instructions 451r 851r Goetze KG Armaturen 7 8...