Label Calibration Button
A hardware button to make a Label Calibration while printer encountering “Media Error” during the cases when first
-time printer start up or
change label or ribbon to another type, such as change using gap label to continuous or black mark labels.
Press C-button for 2 seconds, it will make an auto-
sensing to calibrate the label and ribbon’s parameters.
Note
*
Press C-button is equivalent to the auto-
sensing command “~S,SENSOR” that will cancel on
-printing-job and make the Label
Calibration immediately.
Press
Press
CALIBRATION BUTTON