[page 4] | gpelectric.com
1.1 INTRODUCTION
A Solar Controller (or Charge Controller / Regulator) is an essential component of your photovoltaic solar system. The Controller
maintains the life of the battery by protecting it from overcharging. When your battery has reached a 100% state of charge, the
Controller prevents overcharging by limiting the current flowing into the batteries from your solar array.
The GP-PWM-10-SQ is rated for a continuous solar current input of 10 amps, uses Pulse Width Modulation (PWM) technology
and a unique four stage charging system that includes an optional equalize setting to charge and protect your battery bank.
1.2 SPECIFICATIONS
DESCRIPTION
VALUE
Rated solar panel amps for 10A/10AW
10A
Dimensions (H x W x D):
102 x 130 x 27 mm
4.02 x 5.12 x 1.06 in
Weight: 151 grams / 5.34 oz
Maximum Wire Gauge: #6 AWG
Warranty: 1 year
•
PWM charging
•
4 Battery charging profiles
•
4 Stage charging
•
Monthly equalize option
•
Displays charging current, Bat-
tery voltage and battery state
of charge
•
Reverse polarity protected
•
Temperature compensated
•
RoHS compliant
•
Accepts up to 10 Amps DC
Input Current
The total rated Maximum Power Current
(Imp) of the PV input should not exceed
10 Amps
Nominal System Voltage
15-22 VDC
Max. solar cell array voltage (output has no load)
25 VDC
Lowest operating voltage (solar or battery side)
8 VDC min
Max voltage drop-solar panel to battery
0.25 VDC
Min battery start charging voltage
3 VDC
Soft start charging voltage
3-10 VDC (+/-0.2)
Soft start charging current (50% PWM duty)
Up to 15 Amps
Bulk charge voltage
10-14.6 VDC (+/-0.2)
Absorption charging voltage at 25°C
LTO type battery
14.0 VDC (+/-0.2)
GEL
14.1 VDC (+/-0.2)
AGM (Default)
14.4 VDC (+/-0.2)
LiFePO4
14.4 VDC (+/-0.2)
WET
14.7 VDC (+/-0.2)
Calcium
14.9 VDC (+/-0.2)
Absorption transits to Equalizing or Float condition:
Charging current drops to
14.9 Amps (+/-0.1)
Or Absorption charging timer timed out
4 hours
Equalizing charging active
Only for WET or Calcium battery
10 VDC (+/-0.2)
Automatic equalizing charging periodical
28 days
Equalizing charging voltage at 25°C
15.5 VDC (+/-0.2)
Equalizing charging timer timed out
2 hours
Float charging voltage at 25°C
13.6 VDC (+/-0.2)
For LTO and LiFePO4 battery
13.6/14.0 VDC (+/-0.2)
For Gel, AGM, WET and Calcium
13.6 VDC (+/-0.2)
Voltage control accuracy
+/-1%
Battery temperature compensation coefficient
-24 mV/°C