2. WARNINGS
Disconnect all power sources
Electricity can be very dangerous. Installation should be performed only
by a licensed electrician or qualified personnel.
Battery and wiring safety
Observe all safety precautions of the battery manufacturer when handling
or working around batteries. When charging, batteries produce hydrogen
gas, which is highly explosive.
Wiring connections
Ensure all connections are tight and secure. Loose connections may generate
sparks and heat. Be sure to check connections one week after installation to
ensure they are still tight.
Work safely
Wear protective eye wear and appropriate clothing during installation.
Use extreme caution when working with electricity and when handling
and working around batteries. Use properly insulated tools only.
Observe correct polarity
at all times
Reverse polarity of the battery terminals will cause the controller to give
a warning tone. Reverse connection of the array will not cause an alarm
but the controller will not function. Failure to correct this fault could
damage the controller.
Do not exceed the GP-PWM-
10-SQ Amp current and max
voltage ratings
The current rating of the solar system is the sum of the Maximum Power
Current (Imp) of the solar PV strings in parallel. The resulting system Imp
current is not to exceed 10A. The voltage of the array is the rated open
circuit voltage (Voc) of the PV array and is not to exceed 28V. If your
solar system exceeds these ratings, contact your dealer for a suitable
controller alternative
.