gpelectric.com | [page 23]
6.1.12 STATISTIC DATA
Including total charging amp-hrs, total discharging amp-hrs, total power consumption, numbers of operating days, over-
charges and full-charges.
PAGE
DISPLAYED ITEM/PARAMETER
DESCRIPTION
1
C-D-Chg: 0AH
The charging amp-hrs
C-D-Lod: 0AH
Total discharging amp-hrs
E-Chg: 0KWH
Total power generation
E-Lod: 0KWH
Total power consumption
2
Rundays: 10D
Total number of operating days
LVD-Count 0
Total number of over-charges
Full-count 0
Total number of full-charges
6.1.13 HISTORICAL DATA OF THE CURRENT DAY
(
Historical data
including: the current day’s min. battery voltage, the current day’s max. battery voltage, the current day’s
max. charging current, the current day’s max. discharging current, the current day’s max. charging power, the current
day’s max. discharging power, the current day’s charging amp-hrs, the current day’s discharging amp-hrs, the current
day’s total power generation and the current day’s total power consumption)
OPERATION AND DISPLAY
Statistics icon
Number of operating days: 9
Number of over-discharges: 5
ANALYSI
TOTAL
DAYS: 9
LVDC:5
Historical data icon
The current day’s min battery voltage
is 11.5V
The current day’s max battery voltage
is 11.6V
Historical data of day XXXX (counting
backwards)