[page 20] | gpelectric.com
OPERATION AND DISPLAY
PAGE ITEM TO SET
DISPLAYED ITEM/
PARAMETER
PARAMETER AND
SETTING RANGE
1
Battery system voltage
BatSysVol
12V, 12V system
24V, 24V system
36V, 36V system
48V, 48V system
AUTO, auto recognition
Battery type
BatType
SLD, sealed lead-acid battery
FLD, open lead-acid battery
GEL, gel battery
LI, lithium battery
USE, user defined
Nominal battery capacity
Capacity
0 to 9999
Device address
Address
1 to 60
2
Over-voltage threshold
OverVolDsc
9.0 to 17.0V
Charging limit voltage
ChgLimtVol
9.0 to 17.0V
Equalizing charging voltage
EquChgVol
9.0 to 17.0V
Boost charging voltage
BstChgVol
9.0 to 17.0V
3
Floating charging voltage
FltChgVol
9.0 to 17.0V
Boost charging recovery voltage
BstChgRev
9.0 to 17.0V
Over-discharge recovery voltage
LowVolRev
9.0 to 17.0V
Under-voltage warning level
UndVolWrn
9.0 to 17.0V
4
Over-discharge voltage
LowVolDsc
9.0 to 17.0V
Over-discharge time delay
LVD Delay
0 to 60s
Equalizing charging time
Equ-Time
0 to 300MIN
Boost charging time
Bst-Time
0 to 300MIN
5
Equalizing charging interval
Equ-Inv
0 to 30D (days)
Temperature compensation
Temp-Com
-(3 to 5) mV/ °C/ 2V
Light control time
L-CON-T
0 to 60MIN
Light control voltage
L-CON-V
5 to 11V
6
LCD screen backlight time
BackLight-T
1 to 600s (ON indicates the screen is lit
constantly)
Fault voice alarm
Voice Alarm
ON, voice alarm enabled
OFF, voice alarm disabled
Clear historical data
<ClrHistoryData>
Select YES for execution
Reset to factory settings
<FoctoryDefault>
Select YES for execution
1) In this manual, “n” assigned with a value of 1, 2, 3 or 4 denotes a battery system of 12V, 24V,
36V or 48V accordingly.
2) Before setting parameters, first refer to the User Manual of the corresponding controller. As
some parameters are not settable, operation of setting these parameters on the display unit will be
deemed as invalid or impossible by the controller.
Note