B36
22
4.
Machine
is
not
running although the
foot pedal is pressed.
1. The plug might be displaced.
2. Pedal switch might be out of
order.
3. Contactors in the electricity
network might be out of order.
1. Check the plug.
2. Check the SWITCH. Change them
if they are out of order.
3.
Check the contactors.
5.
Emergency Stop is not
running.
1. Emergency stop contact might
be out of order.
2. Cable Connections might be
unplugged.
1. Change the emergency stop
button.
2. Check the cable connections.
6.
Machine is making
noise.
1. Bearings might be broken
down.
2. Motor's propeller cap might be
rubbing.
3. Gears might be broken down.
4. There might be no oil in the
reducer.
5. Missing phase might come to
the electric supply system which
the machine is connected.
6. Machine might have difficulty
over its capacity.
7. Brake might not be released or
brake lining might scrape after
being broken down in the
electromagnetic braked machines.
1. Check the bearings.
2. Check the propeller cap.
3. Check the gears.
4. Check the reducer oil.
5. Check the phases in the network.
6. Check the bent iron according to
the capacity plate.
7. Check whether the brakes are
running or not and the brake linings.
7.
Machine is leaking
oil.
1. Reducer ventilation cap might
not be mounted.
2. Motor seal might be leaking
oil.
3. Reducer connection bolts might
be loose.
1. Check whether the plug is
mounted or not.
2. Check the motor from the
propeller side. If there is oil change
the motor seal.
3. Check the connection bolts and if
loose screw.
Содержание B36