General Machine Products
(KT), LLC
2. Critical points that dramatically affect the operation of the cable blowing
machine.
•
Pressure on the cable should be set as per the instructions.
•
Rollers to be closed at all times when cable is installed into machine.
•
Cord seals in air chamber correctly fitted to provide good sealing.
•
Correct cable seal fitted.
•
Tube fully connected and pressure
-
tested.
•
Tube connecting fittings are suitable for operating at 220 PSI air pressure.
•
Tube clamp securely tightened.
•
Compressor capacity 220 PSI and suitable for size of tube being used.
•
Cable drum must be located directly behind and in line with the blowing machine.
•
Air chamber, drive rollers, cable guides, must be clean and free from debris, sludge, dirt,
water and lubricant.
•
The cable must be hand guided into the blowing machine through a dry clean cloth by the
operator wearing work gloves.
•
Ensure the compressed air supply is not applied to the cable until required amount of ca-
ble has been installed.
•
The counter/display is powered by (2) 9 volt batteries. To maximize battery life, turn dis-
play off by pressing power button on left side of display box when unit is not in use.