(KT), LLC
TUBE COLLET AND
CLAMP ASSEMBLIES
89923
12mm O.D.
89921
12.7mm O.D.
89928
14mm O.D.
89925
16mm O.D.
89924
18mm O.D.
Loosen the thumb nut, rotate the swing bolt
to open the air box
Insert the top and bottom tube clamps align-
ing the grooved edge to the outside. Tighten
the 4 screws.
Insert the the top and bottom airbox halves
and tighten the screws
Fit the tube into the air box and tube
clamp.
Slide a tube seal, sized for the tubing you
are using, over the end of the tube.
Fit the tube half way or more into the air
box housing as shown in the photo, posi-
tioning the tube seal so that it sits against
the seal face.
Positioning the tube further into the air
box helps prevent the buckling of smaller
fiber.
Place a cable seal sized to the cable you
are blowing in the wide groove.
Preparing the Whisper for the proper duct size
Measure the OD of the duct. Select the corresponding tube collet and clamps
Other tube sizes available –Contact
GMP for information.
Note:
If the seal has a small taper, place the
large side toward the airbox as shown in
the illustration to the right.