15
8. PROCEDURE FOR CHANGING THE BLOWING PLATES
The Accelair 2 uses two types of blowing plates. One type is for
use in conjunction with the buckle functionality and one with-
out. The buckle plates use (4) M3 cap screws each to retain
them into the machine; the non
-
buckle plates use (3) each. The
supplied 2.5mm Allen wrench will be required for removal.
•
Remove all retaining screws and lift the plates out of the
machine.
•
Inspect the condition of the air seal beneath the lower plate
and replace if necessary (photo overleaf).
•
Replace plates of suitable size into the machine and tighten
the retaining screws firmly but take care not to damage the
aluminium threads.
Retaining
Screws
Retaining
Screws
Retaining
Screws
Retaining
Screws
No screw
No screw