background image

LEDTASKtapeINST

PAGE 5 OF 10

Wet Location 

Wet location is a designation that usually means 

‘outdoor rated’.  LTR-WP Series wet location tape 

is protected by a silicone sheath that protects the 

tape within from moisture and inclement weather.  

To insure proper operation, install only in locations 

that are at least 5 feet away from swimming pools 

and spas.  

Turn Power Off at Circuit 

Breaker Before Installing 

Prior to installation, verify that all components (LED 

tape, connectors, mounting clips, channels and 

power supplies) are compatible.

Determine Location and 

Prepare Mounting Surface 

Locate area where LineDRIVE power supply is to 

be mounted.  Make sure area is clean and free of 

dust and any debris that may hamper installation or 

get in the way of wiring.  Please make sure that the 

wire gauge that you select has voltage drop, 

amperage rating and type (in-wall, dry or wet 

location, etc.) is factored in.

Un-Boxing and Organizing 

Pre-Configured Products

Your LTR-WP Series Wet Location Tape Application 

has been pre-configured, cut and packaged for you.  

Open box and remove contents carefully.  Lay tape 

out over application area and insure that all mea-

surements are accurate.  If not, return in original 

packaging.

WARNING!

DO NOT CONNECT DIRECTLY

TO 120V CURRENT!

DO NOT SUBMERGE

DIRECTLY INTO WATER.

WET LOCATION TAPE IS 

CUT AND CAP ONLY.

LEDTask™ Flexible LED Tape

LTR-P WP Series

Wet Location LED Tape

90

C R I

+

24

VOLT

FIELD

C U T T A B L E

65

IP

2

CLASS

24

TITLE

WET

L O C A T I O N

DO NOT INSTALL

IN SHOWER, SPA

OR POOL

DO NOT IMMERSE

LED STRIP

IN WATER

Verify that power is off

before proceeding.

 

Содержание LEDTask LTR-E Series

Страница 1: ...lation into GM Lighting LED mounting channels for proper heat control 7 To avoid voltage drop ensure that wire gauge used is sufficient to keep under 3 voltage drop See Voltage Drop Chart on Page 7 8 Do not exceed maximum run listed for each tape type and for power supply per circuit on dual circuit models 9 Cut at designated cut points only Fig 1 Cutting anywhere else will result in damage to the...

Страница 2: ... may hamper installation or get in the way of wiring Please make sure that the wire gauge that you select has voltage drop amperage rating and type in wall dry or wet loca tion etc factored in Layout and Pre Configure Components Before You Begin Installation Locate area where LineDRIVE power supply is to be mounted Make sure that this space is free of obstructions and can be easily reached for mou...

Страница 3: ...same procedure for connecting Sure Tite connector The other end of connector is wired into your LineDRIVE power supply Please consult power supply instructions for a step by step for this easy procedure Make sure that you you are connected to the same polarity Warning Make sure that tape is pressed firmly into connector insuring that tape contacts are firmly seated into connector Improper or loose...

Страница 4: ...ut a channel for your installation take note that not all channels accept connectors within them Best to make your connections outside of the channel Cut channels with the lens fitting down to avoid shattering Cut channel using a metal blade in a circular saw or with a hacksaw Make sure you observe all proper safety precautions and wear protective goggles If using a hacksaw insure that channel is ...

Страница 5: ...ris that may hamper installation or get in the way of wiring Please make sure that the wire gauge that you select has voltage drop amperage rating and type in wall dry or wet location etc is factored in Un Boxing and Organizing Pre Configured Products Your LTR WP Series Wet Location Tape Application has been pre configured cut and packaged for you Open box and remove contents carefully Lay tape ou...

Страница 6: ...lace Fig 2 Using Mounting Channels See Using Mounting Channels instructions on Page 4 Drill mounting holes using counter sunk screws by others Fig 3 Lay in tape with using 3M double stick tape to insure that tape is securely in position within channel Attach frosted lens Connectors do not fit in all channels Using Silicone Mounting Clips Using the supplied tube of silicone gel squeeze gel into end...

Страница 7: ...the choice of magentic or electronic is correct for your tape Brightness shifting Power supply is over loaded and is overheating An over loaded power supply will trip the internal auto reset repeat edly turning the system on and off If all else fails We re here for you Call our technical service reps at 866 671 0811 or write to tech gmlighting net 12V Wire Voltage Drop Wire Gauge 10W 83A 20W 1 7A ...

Страница 8: ... SUPPLY 120V EXAMPLE Single Run see voltage drop chart POWER SUPPLY 120V EXAMPLE Multi Run 120VAC V V V V HIGH OUTPUT LED TAPE LONGER RUN WIRING EXAMPLE 12VOR 24V 100W POWER SUPPLY 16 4 16 4 16 4 16 4 32 8 STANDARD OUTPUT LED TAPE LONGER RUN WIRING EXAMPLE 32 8 16 4 16 4 120VAC 12VOR 24V 100W POWER SUPPLY ...

Страница 9: ...WITH TAPE CONTROLLER 120 VAC INPUT OUTPUT GND LUX CONTROLLER V V GND L N USING SWITCHLD DIMMER DRIVER SYSTEM 120 VAC GND L N INPUT OUTPUT LUX CONTROLLER V V GND SWITCHLD DIMMER STANDARD DIMMER USING STANDARD DIMMER WITH LINEDRIVE ELECTRONIC DIMMABLE POWER SUPPLY 120 VAC INPUT OUTPUT GND LINEDRIVE DIMMABLE POWER SUPPLY V V GND L N ...

Страница 10: ... Ridgeland Ave Tinley Park IL 60477 Toll Free 866 671 0811 FAX 708 478 2640 www gmlighting net e mail sales gmlighting net tech gmlighting net 2021 GM Lighting Specifications subject to change without notice ...

Отзывы: