Dry Location 

Dry location is a designation that usually means ‘in-

door’.  LTR Series dry location tape is presented in a 

copper bus that is not encapsulated with a silicone 

sheath.  To insure proper operation, install only in 

locations that are not exposed to moisture, steam, 

inclement weather or leaks of any type.  

For Wet 

Location, go to page 5.

Turn Power Off at Circuit 

Breaker Before Installing 

Prior to installation, verify that all components (LED 

tape, connectors, mounting clips, channels and 

power supplies) are compatible.  

Verify that power 

is off before proceeding.

Determine Location and 

Prepare Mounting Surface 

Locate area where LineDRIVE power supply is to 

be mounted.  Make sure area is clean and free of 

dust and any debris that may hamper installation or 

get in the way of wiring.  Please make sure that the 

wire gauge that you select has voltage drop, 

amperage rating and type (in-wall, dry or wet loca-

tion, etc.) factored in

Layout and Pre-Configure 

Components Before You 

Begin Installation

Locate area where LineDRIVE power supply is to 

be mounted.  Make sure that this space is free of 

obstructions and can be easily reached for 

mounting or maintenance.

WARNING!

DO NOT CONNECT DIRECTLY

TO 120V CURRENT!

PLEASE READ PREVIOUS PAGE

AND FAMILIARIZE YOURSELF

WITH ALL INSTRUCTIONS

BEFORE INSTALLING

LEDTask™ Flexible LED Tape

LTR-E, LTR-P and LTR-S Series

Dry Location LED Tape

90

C R I

+

12

VOLT

DRY

L O C A T I O N

FIELD

C U T T A B L E

20

IP

24

VOLT

2

CLASS

24

TITLE

Use your mind before you unwind!

Please follow all applicable NEC

and local wiring codes.

Follow maximum length

tolerances when using tape.

Max. Length = maximum run length 

from one power feed.

Verify that power is off

before proceeding.

Содержание LEDTask LTR-E Series

Страница 1: ...lation into GM Lighting LED mounting channels for proper heat control 7 To avoid voltage drop ensure that wire gauge used is sufficient to keep under 3 voltage drop See Voltage Drop Chart on Page 7 8 Do not exceed maximum run listed for each tape type and for power supply per circuit on dual circuit models 9 Cut at designated cut points only Fig 1 Cutting anywhere else will result in damage to the...

Страница 2: ... may hamper installation or get in the way of wiring Please make sure that the wire gauge that you select has voltage drop amperage rating and type in wall dry or wet loca tion etc factored in Layout and Pre Configure Components Before You Begin Installation Locate area where LineDRIVE power supply is to be mounted Make sure that this space is free of obstructions and can be easily reached for mou...

Страница 3: ...same procedure for connecting Sure Tite connector The other end of connector is wired into your LineDRIVE power supply Please consult power supply instructions for a step by step for this easy procedure Make sure that you you are connected to the same polarity Warning Make sure that tape is pressed firmly into connector insuring that tape contacts are firmly seated into connector Improper or loose...

Страница 4: ...ut a channel for your installation take note that not all channels accept connectors within them Best to make your connections outside of the channel Cut channels with the lens fitting down to avoid shattering Cut channel using a metal blade in a circular saw or with a hacksaw Make sure you observe all proper safety precautions and wear protective goggles If using a hacksaw insure that channel is ...

Страница 5: ...ris that may hamper installation or get in the way of wiring Please make sure that the wire gauge that you select has voltage drop amperage rating and type in wall dry or wet location etc is factored in Un Boxing and Organizing Pre Configured Products Your LTR WP Series Wet Location Tape Application has been pre configured cut and packaged for you Open box and remove contents carefully Lay tape ou...

Страница 6: ...lace Fig 2 Using Mounting Channels See Using Mounting Channels instructions on Page 4 Drill mounting holes using counter sunk screws by others Fig 3 Lay in tape with using 3M double stick tape to insure that tape is securely in position within channel Attach frosted lens Connectors do not fit in all channels Using Silicone Mounting Clips Using the supplied tube of silicone gel squeeze gel into end...

Страница 7: ...the choice of magentic or electronic is correct for your tape Brightness shifting Power supply is over loaded and is overheating An over loaded power supply will trip the internal auto reset repeat edly turning the system on and off If all else fails We re here for you Call our technical service reps at 866 671 0811 or write to tech gmlighting net 12V Wire Voltage Drop Wire Gauge 10W 83A 20W 1 7A ...

Страница 8: ... SUPPLY 120V EXAMPLE Single Run see voltage drop chart POWER SUPPLY 120V EXAMPLE Multi Run 120VAC V V V V HIGH OUTPUT LED TAPE LONGER RUN WIRING EXAMPLE 12VOR 24V 100W POWER SUPPLY 16 4 16 4 16 4 16 4 32 8 STANDARD OUTPUT LED TAPE LONGER RUN WIRING EXAMPLE 32 8 16 4 16 4 120VAC 12VOR 24V 100W POWER SUPPLY ...

Страница 9: ...WITH TAPE CONTROLLER 120 VAC INPUT OUTPUT GND LUX CONTROLLER V V GND L N USING SWITCHLD DIMMER DRIVER SYSTEM 120 VAC GND L N INPUT OUTPUT LUX CONTROLLER V V GND SWITCHLD DIMMER STANDARD DIMMER USING STANDARD DIMMER WITH LINEDRIVE ELECTRONIC DIMMABLE POWER SUPPLY 120 VAC INPUT OUTPUT GND LINEDRIVE DIMMABLE POWER SUPPLY V V GND L N ...

Страница 10: ... Ridgeland Ave Tinley Park IL 60477 Toll Free 866 671 0811 FAX 708 478 2640 www gmlighting net e mail sales gmlighting net tech gmlighting net 2021 GM Lighting Specifications subject to change without notice ...

Отзывы: